Rockwell Automation Publication GMC-RM002F-EN-P - June 2013
7
Preface
About This Publication
This manual provides detailed installation instructions for wiring and
troubleshooting your Kinetix 6000 and Kinetix 7000 safe torque-off drives.
Included are interconnect diagrams with Allen-Bradley safety relays, GuardLogix
controllers, and GuardPLC controllers.
Audience
This manual is intended for engineers or technicians directly involved in the
installation and wiring of the Kinetix 6000 and Kinetix 7000 drives, and
programmers directly involved in the operation, field maintenance, and
integration of the Kinetix 6000 and Kinetix 7000 drives in a safe torque-off
application.
If you do not have a basic understanding of the Kinetix 6000 and Kinetix 7000
drives, contact your local Rockwell Automation sales representative for
information on available training courses.
Conventions Used in This
Manual
The following conventions are used throughout this manual:
•
Bulleted lists such as this one provide information, not procedural steps.
•
Numbered lists provide sequential steps or hierarchical information.
• Bold
type is used for emphasis.
Terminology
This table defines acronyms used throughout this manual.
Acronym
Full Term
Definition
EN
European Norm
European Standards (EN specifications) developed by the European Committee for
Standardization for the European Union.
ISO
International Organization for
Standardization
Voluntary organization whose members are recognized authorities on standards, each one
representing a different country.
IEC
International Electrotechnical
Commission
Non-profit, non-governmental international standards organization that prepares and
publishes international standards for all electrical, electronic, and related technologies,
collectively known as electrotechnology.
PL
Performance Level
EN ISO 13849-1 safety rating.
SIL
Safety Integrity Level
The measure of a products ability to lower the risk that a dangerous failure could occur.
PFD
Probability of Failure on Demand
The average probability of a system to fail to perform its design function on demand.
PFH
Probability of Failure per Hour
The probability of a system to have a dangerous failure occur per hour.
HFT
Hardware Fault Tolerance
Equals N, where N+1 faults could cause the loss of the safety function. A hardware fault
tolerance of 1 means that 2 faults are required before safety is lost.
STO
Safe Torque-off
Functional safety feature that complies with IEC 61800-5-2.
IGBT
Insulated Gate Bi-polar Transistors
Typical power switch used to control main current.