Rockwell Automation Publication GMC-RM002F-EN-P - June 2013
15
Chapter
2
Safe Torque-off Connector Data
This chapter provides safe torque-off (STO) connector, header, and interface
cable information for the Kinetix 6000 and Kinetix 7000 safe torque-off drives.
Safe Torque-off Connector
Pinout
Headers are available to extend the 9-pin safe torque-off (STO) connector
signals for use in wiring single and multiple safe torque-off drive configurations,
or to defeat (not use) the safe torque-off function.
Table 3 - 9-pin Safe Torque-off (STO) Connector
Topic
Page
Safe Torque-off Connector Pinout
Safe Torque-off Header Configurations
Safe Torque-off
(STO) Connector Pin
Also Applies to These
STO Connector Headers
Description
Signal
1
•
Wiring plug header used in
single-drive applications
•
First-drive wiring header
(2090-XNSM-W) used in
multiple-drive applications
One side of the normally-closed monitoring contact of relay 2
FDBK2+
2
Other side of the normally-closed monitoring contact of relay 2
FDBK2-
3
One side of the normally-closed monitoring contact of relay 1
FDBK1+
4
Other side of the normally-closed monitoring contact of relay 1
FDBK1-
5
Safety enable 2 input
SAFETY
6
Return for safety enable power (both inputs)
SAFETY ENABLE-
7
Safety enable 1 input
SAFETY
8
•
Wiring plug header
•
Motion-allowed jumper
Output power for continuous enable of the safety function, 500 mA, max
24V+
9
Output power return used for continuous enable of safety function
24V_COM
IMPORTANT
Pins STO-8 (internal 24V+ supply) and STO-9 (24V_COM) are used only by the
motion-allowed jumper to defeat the safe torque-off function. When the safe
torque-off function is in operation, the 24V supply must come from an external
source.