Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
121
Chapter 9 Connected Components Workbench Software
USB Status
shows the status of the USB connection. The status is read-only.
Figure 103 - USB Status
Subconfigurations
shows the subconfiguration setup. The subconfiguration setup is
only available when the OID is connected to a receiver; the transmitter does
not require a configuration.
Key elements of subconfigurations include:
•
With DIP switch 1 set to ON, up to four subconfigurations can be created.
•
The General, Muting, and Blanking settings can be adjusted for each
sub-configuration.
•
If a cascading plug-in is installed, the Cascaded Safety Component is
automatically refreshed when a configuration is uploaded from the light
curtain.
•
The four configurations use the same GPIO.
•
If DIP switch 1 is set back to 0, the configuration via the Connected
Components Workbench software is erased.
Figure 104 - Sub-Configuration Setup
General Settings
shows the default general settings. The general settings
apply to both the muting and blanking functions, if these functions are
enabled. See
for descriptions of each setting.
Содержание Allen-Bradley 140M
Страница 8: ...8 Rockwell Automation Publication 450L UM001F EN P March 2022 Table of Contents Notes ...
Страница 20: ...20 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 2 Safety Concepts Notes ...
Страница 108: ...108 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 7 Status Indicators and Troubleshooting Notes ...
Страница 114: ...114 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 8 Safety Instructions Notes ...
Страница 184: ...184 Rockwell Automation Publication 450L UM001F EN P March 2022 Appendix B Typical Installations Notes ...
Страница 190: ...190 Rockwell Automation Publication 450L UM001F EN P March 2022 Index ...
Страница 191: ...Rockwell Automation Publication 450L UM001F EN P March 2022 191 GuardShield Safety Light Curtain User Manual ...