104
Rockwell Automation Publication 450L-UM001F-EN-P - March 2022
Chapter 7 Status Indicators and Troubleshooting
For fault conditions 0…13 and corrective actions, see
.
Table 56 - Status Indicators for External Errors and System Errors
No.
Error
First Status Indicator
Second Status Indicator
Short Description
Marking
(Name)
Color
Blink
Frequency
Duty Cycle
(On/Off)
Marking (Name)
Color
Blink
Frequency
Duty Cycle
(1)
0
Configuration changed
(2)
STS
Red/ Green
1 Hz
50:50
—
—
—
—
1
Internal lockout
(3)
STS
Red
ON
100:0
—
—
—
—
2
STS
Red
1 Hz
50:50
RES
Amber
1 Hz
10:90
3
Start error
STS
Red
1 Hz
50:50
RES
Amber
1 Hz
90:10
4
Ambient light or EMC
disturbances
STS
Red
1 Hz
50:50
—
—
—
—
5
Short circuit between OSSDs
to 24V DC (lockout)
STS
Red
1 Hz
50:50
OUT
Red
1 Hz
50:50
6
Error supply voltage
STS
Red
1 Hz
50:50
Stick type (transmitter
or receiver)
Green
1 Hz
50:50
7
24V DC connected to
transmitter plug-in input
STS (Tx)
Green
ON
100:0
Stick type transmitter
Green
1 Hz
50:50
8
Mixed design of 450L-B and
450L-E sticks or stick
identification mismatch when
beam coding is used
STS (Tx)
Red
1 Hz
50:50
Regional light intensity
level 1 and level 2
Green
1 Hz
50:50
9
Invalid DIP switch setting
STS
Green
1 Hz
50:50
Stick type receiver
Green
1 Hz
50:50
10
Muting timing error
(450L-E only)
STS (Rx)
Red
1 Hz
50:50
MUT
Amber
1 Hz
90:10
11
Muting sequence error
(450L-E only)
STS (Rx)
Red
1 Hz
50:50
MUT
Amber
1 Hz
10:90
12
Blank error (450L-E only)
STS
Red
1 Hz
50:50
BLK
Amber
1 Hz
50:50
13
Cascade error (450L-E only)
STS
Red
1 Hz
50:50
CAS
Red
1 Hz
50:50
14
Failure in a safety component
or logic that is connected to a
Top I/O-Plug-in
STS
Red
1 Hz
50:50
Regional light intensity
level 2
Green
1 Hz
50:50
15
Failure in a safety component
or logic that is connected to a
Bottom Plug-in
STS
Red
1 Hz
50:50
Regional light intensity
level 1
Green
1 Hz
50:50
(1)
The interpretation is first value on time, second value off time, for example, 10:90 means 10% on, 90% off.
(2) Error: If there is an error, remove the error source. For manual restart, activate the Restart button.
(3) If there is a lockout, remove the lockout source. Lockout requires power recycling or adequate action (see
.
ATTENTION:
If automatic restart is used, the system starts immediately.
Содержание Allen-Bradley 140M
Страница 8: ...8 Rockwell Automation Publication 450L UM001F EN P March 2022 Table of Contents Notes ...
Страница 20: ...20 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 2 Safety Concepts Notes ...
Страница 108: ...108 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 7 Status Indicators and Troubleshooting Notes ...
Страница 114: ...114 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 8 Safety Instructions Notes ...
Страница 184: ...184 Rockwell Automation Publication 450L UM001F EN P March 2022 Appendix B Typical Installations Notes ...
Страница 190: ...190 Rockwell Automation Publication 450L UM001F EN P March 2022 Index ...
Страница 191: ...Rockwell Automation Publication 450L UM001F EN P March 2022 191 GuardShield Safety Light Curtain User Manual ...