Chapter 7 Status Indicators and Troubleshooting
Status Indicator for Normal Operation
lists normal operation status indicators on a 450L safety light curtain
(colors and functions) for normal operation.
The last column in
describes whether the signal displays
simultaneously at both sticks.
•
“No” means that the status indicator shows only the status of the
individual stick.
•
“Yes” means that the status indicator shows the status of the complete
system.
Table 54 - Status Indicators
No.
Marking
Status Indicator Name
Color
Behavior
Description
System
Status
1
STS
Status indicator
Green
On
Power on and system is OK
No
Green
Red
Blinking
Configuration that is changed or receiver was operated
previously with another transmitter
No
Green
Off
Blinking (98:2)
Interference rejection is enabled
No
Green
Red
Blinking (90:10)
Optical interference is detected (this status will be indicated,
even if interference rejection is already enabled)
No
Green
Off
Blinking
No
Off
Red
Blinking
No
Red
On
No
2
Transmitter
Green
On
Plug-in identifies stick as a transmitter
No
Blinking 1 Hz (50:50)
See
No
Blinking 1 Hz (98:2)
Reduced range and/or beam coding is activated
No
Off
Stick is receiver
No
3
Receiver
Green
On
Plug-in identifies stick as a receiver
No
Blinking 1 Hz (98:2)
Reduced range and/or beam coding is activated
No
Off
Stick is transmitter
No
4
OUT
Safety outputs
Green
On
Safety outputs are on (receiver)
No
Red
On
Safety outputs are off (receiver)
No
—
Off
Transmitter
No
5
Regional light intensity level 1
Green
On
Bottom half zone is not interrupted and intensity is OK
Yes
Blinking 1 Hz (50:50)
Bottom half zone intensity is at the limit
Yes
—
Off
Bottom half zone interrupted
Yes
6
Regional light intensity level 2
Green
On
Top half zone is not interrupted and intensity is OK
Yes
Blinking 1 Hz (50:50)
Top half zone intensity is at the limit
Yes
—
Off
Top half zone interrupted
Yes
7
RES
Start
Amber
On
Start required (receiver)
No
—
Off
No start is required (receiver)
No
8
MUT
Muting
Orange
Off
Light curtain that is not muted
No
On
Light curtain that is muted
No
Orange
Off
Blinking
Muting error
No
9
BLK
Blanking
Orange
Off
No blanking feature selected
No
Orange
On
Blanking feature that is selected
No
Orange
Off
Blinking
Blanking error
No
10
CAS
Cascading
Red
Off
No cascading plug-in that is inserted or Tx OSSDs of connected
cascade are in ON-state (Rx only)
No
On
OSSDs of connected cascade are in OFF-state (Rx only)
No
Red
Off
Blinking
Error cascading plug-in
No
Содержание Allen-Bradley 140M
Страница 8: ...8 Rockwell Automation Publication 450L UM001F EN P March 2022 Table of Contents Notes ...
Страница 20: ...20 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 2 Safety Concepts Notes ...
Страница 108: ...108 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 7 Status Indicators and Troubleshooting Notes ...
Страница 114: ...114 Rockwell Automation Publication 450L UM001F EN P March 2022 Chapter 8 Safety Instructions Notes ...
Страница 184: ...184 Rockwell Automation Publication 450L UM001F EN P March 2022 Appendix B Typical Installations Notes ...
Страница 190: ...190 Rockwell Automation Publication 450L UM001F EN P March 2022 Index ...
Страница 191: ...Rockwell Automation Publication 450L UM001F EN P March 2022 191 GuardShield Safety Light Curtain User Manual ...