Installation
Transport System Installation
QuickStick HT User Manual
185
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
Mounting the QuickStick HT 5700 Inverters
Install the QSHT 5700 inverters system inside an approved metal enclosure (IP54 min). Run
input power wiring in conduit (grounded to the enclosure) outside of the enclosure. Separate
signal and power cables. The QuickStick HT 5700 (QSHT 5700) inverters must be spaced in
the enclosure by aligning the zero-stack tab and cutout as shown in
terns, see the
Kinetix 5700 Servo Drives User Manual
,
vice and exclusion zones that are identified in
are maintained.
Figure 5-2: QSHT 5700 Inverter Mounting
The QuickStick HT 5700 inverter is powered by the 2198-Pxxx DC-bus power supply (see
Input Power Configurations for Kinetix 5700 Power Supplies
and
Ground Screw/Jumper Set-
tings
in the
Kinetix 5700 Servo Drives User Manual
). The example shown in
is powered by the DC-bus power supply (positioned on the left) with inverter mod-
ules mounted to the right.
The QSHT 5700 inverter mounts with the 2198-Pxxx DC-bus power supplies using the Rock-
well Automation zero-stack tab and cutout system. See the
Kinetix 5700 DC-bus Power Sup-
ply Installation Instructions
.
QSHT 5700 Inverter
(typical)
2198-Pxxx PS
(typical)
MOD
NET
2
1
1
4
I/O
Shared-bus Connection Systems
(DC-bus and 24V DC)
Zero-stack Tab/Cutout
(typical)