Rocks OK-03.0030 Скачать руководство пользователя страница 5

from the measuring point

• The multimeter may only be operated by a qualified adult, not under the influence of  

   alcohol and drugs

• Before measuring, make sure that the correct range, parameter and measurement port  

   are selected

• Despite the fact that the multimeter has protection systems, always take effective care  

   of your work safety 

• Never measure the current on devices with an amperage greater than 10A

• Never use a damaged, chipped, cracked or poorly attached accessory.

• Never work with a multimeter on wet ground and in rainworking conditions. First of all,  

   take care of your own work safety and the safety of outsiders.

• A tool designed for use by qualified adults 

ATTENTION! Despite the inherently safe construction, the use of safety measures  

and additional protective measures, there is always a residual risk of injury during 

work.

ASSEMBLY AND OPERATION

The multimeter works with the appropriate accuracy under the appropriate operating 

conditions: temperature 23˚C and humidity below 80%. The correct calibration of the 

device is guaranteed for 12 months.

Input impedance: 10M

Ω

, overload protection: 600V DC or AC RMS The standard frequency 

of the alternating current with sine waves is 40Hz - 1KHz For a current with a different 

waveform characteristic of 40 Hz-200 Hz. 

It is absolutely forbidden to perform measurements in circuits with a voltage exceeding 

600V, as this may result in damage to the device or electric shock. The multimeter has  

an automatic switch-off after 15 minutes. You can turn it off: 

•  turn the main switch to the OFF position 

•  press and hold the SEL button 

•  during this time turn the main switch to any other position and after 4 buzzer signals 

  the function is disconnected. When you want to turn it on, turn the main switch 

    to the OFF position and then select any other position.

Connection of measuring probes

• Insert the black - negative wire into the 

 port 

• Red - Place positive wire in the port 

 

  

• When measuring with clamps, it is recommended to remove the test

   leads to reduce the risk of electric shock.

DC voltage measurement 

• Set the main dial to the V DC position    

• Take the measurement 

• You can set a convenient measuring range by pressing

   the middle RANGE key

Содержание OK-03.0030

Страница 1: ...MANUAL INSTRUKCJA OBS UGI BEDIENUNGSANLEITUNG OK 03 0030 Multimeter clamp meter AUTOMAT T RMS LED NCV SYSTEM Multimetr miernik c gowy AUTOMAT T RMS LED NCV SYSTEM Multimeter Klemmmesser AUTOMAT T RMS...

Страница 2: ...TA DANE TECHNICZNE TECHNISCHE DATEN EN PL DE DC voltage Napi cie sta e DC Gleichspannung 1mV 1000V 0 5 3 AC voltage Napi cie zmienne AC Wechselstrom Spannung 1mV 750V 1 2 10 Resistance Rezystancja Wid...

Страница 3: ...input port for the black wire Port COM ujemny port wej ciowy na czarny przew d COM Port negativer Eingangsport f r schwarzes Kabel 7 V port positive input port for red wire Port V dodatni port na czer...

Страница 4: ...V 2xAAA batteries It is small and easy to carry has an LCD screen backlight and an additional built in flashlight to illuminate the measurement site The multimeter accurately measures the following cu...

Страница 5: ...0 The correct calibration of the device is guaranteed for 12 months Input impedance 10M overload protection 600V DC or AC RMS The standard frequency of the alternating current with sine waves is 40Hz...

Страница 6: ...nt is measured on the bundle more than one conductor the result will be incorrect Resistance measurement Set the main dial to the position Take the measurement You can set a convenient measuring range...

Страница 7: ...switch to position put the testers in parallel to the diode circuit red at the input if the buzzer gives a signal it means working diode To measure the diode voltage press the SEL button the diode ico...

Страница 8: ...owy styk z miejscem pomiaru by prawid owo pod czony do odpowiedniego portu w urz dzeniu i by odpowiednio izolowany w przeciwnym razie grozi pora enie pr dem Podczas zmiany parametr w lub zakresu pomi...

Страница 9: ...oz czona Kiedy chcesz j w czy przekr prze cznik g wny w pozycj OFF i nast pnie wybierz inn dowoln pozycj Gdy chcesz go w czy przestaw wy cznik g wny do pozycji OFF a nast pnie wybierz dowoln inn pozyc...

Страница 10: ...Mo esz ustawi dogodny zakres pomiarowy przyciskaj c rodkowy klawisz RANGE Pomiar temperatury Ustaw pokr t o g wne na pozycj Wybierz jednostk C K za pomoc przycisku SELECT Wykonaj pomiar Bezkontaktowe...

Страница 11: ...bwodem EINLEITUNG Dieses Ger t ist ein Zangenmultimeter mit einer gro en 4 stelligen LCD Anzeige und automatischer Bereichswahl Das Multimeter wird verwendet um grundlegende Stromgr enzumessen DasInst...

Страница 12: ...ie zun chst f r Ihre eigene Arbeitssicherheit und die Sicherheit von Au enstehenden Ein Werkzeug zur Verwendung durch qualifizierte Erwachsene by AUFMERKSAMKEIT Trotz der eigensicheren Konstruktion de...

Страница 13: ...dr cken Wechselspannungsmessung Stellen Sie das Hauptw hlrad auf die Position V AC Nehmen Sie die Messung vor Sie k nnen einen bequemen Messbereich einstellen indem Sie die mittlere RANGE Taste dr cke...

Страница 14: ...ie Messung vor Ber hrungslose Spannungserkennung NCV Diese Funktion erfordert keine Sonden die Messung erfolgt durch den eingebauten NCV Detektor im oberen Teil Hauptschalter auf NCV Position drehen B...

Страница 15: ...er korrekte Spannungswert betr gt 500 800 mV Wenn der Spulenstromkreis unterbrochen oder die Polarit t vertauscht ist zeigt das Messger t OL an Trennen Sie beim Messen von Dioden die Stromversorgung v...

Страница 16: ...netyczna Elektromagnetische Richtlinie 2014 30 EU And it is compliant with EN standards I jest zgodny ze standardami EN Und es ist konform mit den EN Normen EN 61010 1 EN 61326 1 2013 Responsible pers...