RJ45-Connector
Z-Motor
RJ45-Connector
X-Motor
Screwterminal
Z-Motor
Screwterminal
X-Motor
Screwterminal
ENCODER
RJ45-connector
ENCODER
26
4 Inputs
max 12V
INPUTS AND OUTPUTS
Various inputs and outputs are available for connection to the machine.
2 inputs for 1 incremental encoder (RJ45 and screw terminal)
2 inputs for 1 X-axis drive system (RJ45 and screw terminal)
2 inputs for 1 X-axis drive system (RJ45 and screw terminal)
(ATTENTION: Either use RJ45 -OR- terminals, not both!)
1 supply voltage input for 12V round plug
4 digital inputs for emergency stop circuit, limit switches and error signals
4 outputs for 12 or 24V (external) for switching purposes
1 SUB-D 15 Expansion connector for an external control unit
1 Ground connection
All screw terminals are removable.
The terminal assignment is shown on the sticker.
4 Outputs 12-24V,
300mA
Extension
connector
Power supply
12V/1A
Grounding
Содержание ELS 4 Basic