6. FILLING AND EMPTYING THE SPA

Never use the air blower circuit to fill the spa.

The bath can be connected to the water and sewage systems 

permanently or the bath can be filled and drained by means of flexible 

hoses disconnected after each operation. The flexible hose set of the 

bath includes a T-pipe with a 1/2” coupling for filling of the bath through 

the hydro-massage jets. The fixed piping system includes release valves 

located near the skimmer-filter; at the outlets of which fixed or removable 

hose connection with the sewage system should be provided.

It is recommended that the bath is permanently connected to the 

sewage system due to the risk of water overflowing through the 

emergency overflow system.

7. VENTILATION

The possible high temperature of the water in the spa (approximately 

39 ºC) leads to steam condensation.

The spa room must have adequate ventilation. If it does not, it is 

recommended that you install a dehumidifier to keep the air humidity 

at a constant temperature and prevent steam from condensing on the 

ceiling and on the floor.

For the correct maintenance of the wood, the relative air humidity in the 

room must be kept below 65% when the spa is not being used. 

During use and due to the evaporation caused by the hydromassage 

and the movement of the water, this value normally reaches 90 or 95%.

The air humidity can be kept constant by the use of fans controlled 

by hygrostats or dehumidifiers adapted to the size of the room. Your 

installer or distributor can offer you advice on this. If the room has air 

conditioning, the condenser is not necessary. If the spa is outdoors or 

in an open space, these apparatuses are not necessary.

Содержание BROADWAY FAMILY

Страница 1: ...1 Installation Instructions SPA BROADWAY FAMILY...

Страница 2: ...NG THE EQUIPMENT 4 2 PREPARING THE PLACE FOR THE INSTALLATION 4 3 POSITIONING THE SPA 4 4 ELECTRICAL CONNECTIONS 5 4 1 GROUNDING CABLE CONNECTION 5 4 2 MAINS CONNECTION 5 5 HYDRAULIC CONNECTION 5 6 FI...

Страница 3: ...ge whirlpool jet J 1 pcs fixed mini ozone jet K 1 pcs 3 4 black tub drain H 1 pcs 6 hydromassage aeration regulators 2 hydromassage diverters DISINFECTION 1 ozone generator 10W 250mg h UV lamp optiona...

Страница 4: ...nd how you are going to fill and empty the spa The floor must be level There must be adequate ventilation in closed interior locations You must bear in mind the materials used on the wall and ceilings...

Страница 5: ...al power by pressing the test button on the differential current switch 230V AC 7 2 electric connection with kW efficiency protected 3x6 mm 2 Skimmer filter Sewage connection 50 mm Water connection 1...

Страница 6: ...ble high temperature of the water in the spa approximately 39 C leads to steam condensation The spa room must have adequate ventilation If it does not it is recommended that you install a dehumidifier...

Страница 7: ...7...

Страница 8: ...40 59 41 212 0 23 40 03 39 Fax 212 0 23 40 59 42 Roca GmbH Feincheswiese 17 56424 Staudt Deutschland Tel 49 0 2602 93610 Fax 49 0 2602 936 122 Roca Polska Sp z o o ul Wyczolkowskiego 20 44 109 Gliwice...

Отзывы: