ROC Crown Gold Series Скачать руководство пользователя страница 4

4

Leading by professional

1.  condensing Heat exchange system 

The product uses condensing type heat exchange design,with the unique patent of 
circular stainless steel heat exchanger.The tripling circuit coil pipe design absorbs the 

flue gas heat adequately,efficiency can reach 108%,super low CO and NO

X

 product.

The flue gas temperature can reach 50

.The condensing result is abvious,green 

and environmental.

2.  adopt cuspidate PWM gas proportion control technique.

Our key technology is the control system. According to the feedback information from 

the temperature and pressure sensor. System can accommodate the gas supply 
volume automatically, control heating and domestic hot water temperature, which is 
above the temperature you have set so that you can save much energy.

3.  adopt multiple safe protection device

Our products have the most safe protection device in the same trade. Adopt 

equilibrium force air exhaust system in which the combustion chamber and air 
exhaust  channels are completely hermetic. It can absorb the fresh air, exhaust 

the waste air after burning and eliminate the harm of CO for human’s body. There 
are multiple over-heat protection device, protection for flameout, protection for flue 

building up, protection for over-pressure, multiple protection for preventing frostbite.

4.  adopt super mute running way

Adopt device for assimilating noise in the burner to assimilate all the noise when 

burn. At the meantime, with the low-noise excellent fan, circulation pump and flawless 

hermetic system,all noise will be the least. You will have a peaceful life space.

feature of product 

Содержание Crown Gold Series

Страница 1: ...USER S GUIDE Condensing Gas Wall hung Boilers Crown Gold Series...

Страница 2: ...nt rules and instructions of manufacturer Manufacturer will not take any responsibility for those person harm and property damage causing by incorrect installation Gas boiler only use for supplying he...

Страница 3: ...Items for safety 9 Function and use for main control panel 12 First operation 14 Turn on off the machine correctly 15 Cleaning and maintenance 16 Make sure the following items before repairing 17 Tech...

Страница 4: ...ich is above the temperature you have set so that you can save much energy 3 adopt multiple safe protection device Our products have the most safe protection device in the same trade Adopt equilibrium...

Страница 5: ...e energize performance If the power breaks when the machine is running this performance will save all the orders which is saved before the power breaks it will carry out all the orders automatically a...

Страница 6: ...ere is leakage combustion will be cut automatically Machine reruns after pouring the water according to the way to first operation 6 self diagnoses device This device can avoid system safety losing co...

Страница 7: ...had better allocate a manostat if pressure is unstable 3 Use Except heating and D H W gas boiler can t be used in other ways 4 Check the switch for gas before use Check the middle switch connected on...

Страница 8: ...and contact local gas supplier 8 Prevent frostbite in winter When heating heater must be unimpeded including water electricity gas There is a prevent frostbite device in the heater so the heater will...

Страница 9: ...mperature indication Operation sign works Winter mode Malfunction Display lock Anti freezing Summer mode Overheat protector Pump Water pressure switch Fan Air pressure switch Room thermostat 1 2 3 4 5...

Страница 10: ...ting and hot water temperature Down button Reduce the heating and hot water temperature Reset button It will reset the malfunction and restart the gas boiler when malfunction occurs After entering the...

Страница 11: ...function reason Air pressure or air speed malfunction flue thermocouple disconnects NTC open circuit and short circuit NTC open circuit and short circuit When the pipe water temperature is higher than...

Страница 12: ...rom 30 55 C The speed of water output depends on the length of the pipe After all cold water flows out hot water will flow out 1 Pour Water For the Heating system 1 Open the valve for the pouring wate...

Страница 13: ...ter will overflow from the condensing water outlet 1L h before using the product a water pipe must be connected to the condensing water to lead it to the floor drain first operaton notice Because of i...

Страница 14: ...2kgf cm2 2 not Be Used For a short Period Gas boiler needs to be off if it won t be used for a short period Press and then the machine turns off When the gas boiler is under OFF state please keep the...

Страница 15: ...ime once a year check on time twice a year Attention necessary not necessary Maintenance Check the obturator Clean the heat exchanger beyond the flue Clean the combustion chamber fan and inner pipe Ch...

Страница 16: ...ignite some unusual noise when start a smoke smell Bad heating effect no hot water or hot water isn t hot Way to Maintain Close the mid valve connected by gas pipe Don t turn on or off the electrical...

Страница 17: ...inimum pressure of D H W Expansion vessel capacity Expansion vessel preload capacity Maximum heating system pressure Nominal nature gas pressure PERFORMANCE Maximum heating water temperature Minimum h...

Страница 18: ...D H W Outlet G1 2 C C W Inlet G1 2 D B F W Inlet G3 4 E W O H Outlet G3 4 D H W Domestic Hot Water C W Cold Water B F W Back Flow Water W O H Water Of Heating A Gas Inlet G3 4 B D H W Outlet G1 2 C C...

Страница 19: ...Packing list in a Whole Unit appendix 1 Host machine 2 Installation bag Two pothooks Two expansion bolts used for fix the pothook 3 Accessory bag One user s guide...

Страница 20: ......

Отзывы: