Robustel R3010 User Guide
RT_UG_R3010_v.1.0.2 8 Aug., 2018 42
Confidential
3.8
Interface > Ethernet
This section allows you to set the related parameters for Ethernet. There are two Ethernet ports on R3010 Gateway,
including ETH0 and ETH1. The ETH0 and ETH1 can freely choose from lan0
~
lan1, but at least one LAN port must be
assigned as lan0. In another word, ETH0+ETH1 can be configured as lan0+lan0, lan0+lan1, or lan1+lan0. Both of ETH0
and ETH1 default to lan0, and their default IP are 192.168.0.1/255.255.255.0.
Click
button of eth0 to configure its parameters. The port assignment can be changed by selecting from the drop
down list.
Port Settings
Item
Description
Default
Index
Indicate the ordinal of the list.
--
Port
Show the editing port, read only.
--
Port Assignment Choose the Ethernet port’s type to lan0 or lan1.
lan0