background image

Robustel GoRugged M1000 MP User Guide                                                                                                       

 

 

 
RT_UG_M1000 MP_v.2.0.0                                                                  Aug. 11, 2017                                                                  42/44 
Confidential 

4.3

 

Glossary 

Abbreviations 

Description 

AC 

Alternating Current 

APN 

Access Point Name of GPRS Service Provider Network 

CE 

Conformité Européene (European Conformity) 

CHAP 

Challenge Handshake Authentication Protocol 

CTS 

Clear to Send 

dB 

Decibel 

dBi 

Decibel Relative to an Isotropic radiator 

DC 

Direct Current 

DCD 

Data Carrier Detect 

DCE 

Data Communication Equipment (typically modems) 

DCS 1800 

Digital Cellular System, also referred to as PCN 

DI 

Digital Input 

DO 

Digital Output 

DSR 

Data Set Ready 

DTE 

Data Terminal Equipment 

DTMF 

Dual Tone Multi-frequency 

DTR 

Data Terminal Ready 

EMC 

Electromagnetic Compatibility 

EMI 

Electromagnetic Interference 

ETSI 

European Telecommunications Standards Institute 

GND 

Ground 

GPRS 

General Package Radio Service 

GSM 

Global Standard for Mobile Communications 

IMEI 

International Mobile Equipment Identification 

kbps 

kbits per second 

LED 

Light Emitting Diode 

MAX 

Maximum 

Min 

Minimum 

MO 

Mobile Originated 

MS 

Mobile Station 

MT 

Mobile Terminated 

PAP 

Password Authentication Protocol 

PC 

Personal Computer 

PCN 

Personal Communications Network, also referred to as DCS 1800 

PCS 

Personal Communication System, also referred to as GSM 1900 

PDU 

Protocol Data Unit 

PPP 

Point-to-point Protocol 

PIN 

Personal Identity Number 

PSU 

Power Supply Unit 

Содержание GoRugged M1000 MP

Страница 1: ...GoRugged M1000 MP Industrial Cellular Modem 1 RS 232 RS 485 1 USB Host User Guide Guangzhou Robustel Technologies Co Ltd www robustel com...

Страница 2: ...ies Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective owners Disclaimer No part of this document may be reproduced in any form without the wri...

Страница 3: ...cted to the modem for proper operation Only use approved antenna with the modem Please contact authorized distributor to find an approved antenna Always keep the antenna with minimum safety distance o...

Страница 4: ...direct sunlight caustic harsh chemicals dust or water Do not try to disassemble or modify the modem There is no user serviceable part inside and the warranty would be void Do not drop hit or shake the...

Страница 5: ...tronic Information Products ACPEIP the EPUP i e Environmental Protection Use Period of this product is 20 years as per the symbol shown here unless otherwise marked The EPUP is valid only as long as t...

Страница 6: ...and Type Approval Information PIN Assignment LED Indicators Mount the Modem file format device pictures May 13 2015 V1 2 1 Updated information about Regulatory and Type Approval Information picture fo...

Страница 7: ...ce 19 2 8 Power Supply 19 Chapter 3 Modem Operation 20 3 1 AT Command Set 20 3 1 1 Start SecureCRT 20 3 1 2 AT Command Examples 22 3 2 Using Short Message Service 22 3 2 1 Sending a Short Message 22 3...

Страница 8: ...ol via AT commands Hayes 3GPP TS 27 007 and 27 005 Connecting TCP IP and sending SMS via AT commands Supporting 1 x RS 232 RS 485 Supporting 1 x mini USB 2 0 high speed interface 40 to 85 C extended o...

Страница 9: ...pply 1 x Quick Start Guide with download link of other documents or tools Note If any of the above items is missing or damaged please contact your Robustel sales representative Optional Accessories so...

Страница 10: ...Guide RT_UG_M1000 MP_v 2 0 0 Aug 11 2017 10 44 Confidential RS 232 serial cable DB9 male to DB9 female Mini USB cable DB9 male terminal block for RS 485 serial connection AC DC power adapter 12V DC 1...

Страница 11: ...85 Connector DB9 female Baud rate 1200 bps to 115200 bps RS 232 RxD TxD RTS CTS GND RS 485 Data A Data B USB Interface Number of ports 1 x mini USB Connector Mini female Speed 2 0 high speed up to 480...

Страница 12: ...1 x RS 232 1 x RS 232 Mini USB Port 1 1 1 1 Input Voltage 6 to 18V DC 6 to 18V DC 6 to 26V DC 6 to 26V DC Air Interface GSM GSM GSM GPRS EDGE UMTS HSDPA HSUPA HSPA GSM GPRS EDGE HSDPA HSUPA HSPA Frequ...

Страница 13: ...RXD M1000 MP Device 3 TXD TXD M1000 MP Device 4 DI DT M1000 MP Device 5 GND GND x 2 6 Data B 485 M1000 MP Device 7 RTS RTS M1000 MP Device 8 CTS CTS M1000 MP Device 9 5V Output DR PIN Assignment for...

Страница 14: ...for dual antenna On 0 5 sec blink for single antenna The current network is connected Note Only available for the 3G module and the indicator will never be lit if the current 3G module does not suppor...

Страница 15: ...the mini USB connector at the bottom of the M1000 MP Modem and connect the other end of the cable to external power supply equipment Note Both 2G and 3G models are supported Note Normally the output...

Страница 16: ...click Remove SIM card 1 Make sure the modem is powered off 2 To remove SIM card press the card with finger until it pops out and then take out the card Note 1 Recommended torque for inserting is 0 5...

Страница 17: ...modem s antenna connector and twist tightly Make sure the antenna is within the correct frequency range provided by the ISP and with 50 Ohm impedance Note Recommended torque for tightening is 0 35 N...

Страница 18: ...modem associated with the wall mounting kit on the wall Note Recommended torque for mounting is 1 0 N m and the maximum allowed is 1 2 N m 2 DIN rail mounting measured in mm Use 3 pcs of ST2 9 8 pan...

Страница 19: ...1000 MP Modem and connect the other end of the cable to an external controller or computer 2 8 Power Supply M1000 MP supports reverse polarity protection but always refers to the figure above to conne...

Страница 20: ...w to configure the M1000 MP Modem 3 1 AT Command Set M1000 MP supports the guidelines known as AT Command Set AT Command Set is an industry standard line oriented command language used to communicate...

Страница 21: ...MP_v 2 0 0 Aug 11 2017 21 44 Confidential 3 Choose Serial as the protocol 4 Choose the relevant COM port and match the parameters as below then click Next Note Please be sure to configure the paramet...

Страница 22: ...card is correctly inserted and the modem needs no password CPIN SIM PIN PIN is required CPIN SIM PUK PUK is required Save parameters to non volatile memory AT W OK The configuring and modifying are sa...

Страница 23: ...1 Type AT CMGF 1 and press Enter 2 Type AT CNMI 2 1 and press Enter 3 When a short message is received the window will show CMIT SM x in which the x is the index number for SMS save position 4 Type A...

Страница 24: ...te all read send and unsent messages 4 Delete all messages Note The SMS sending command may a little different vary from module to module For the specific command of different module the corresponding...

Страница 25: ...dial via Windows Note The following steps are based on Windows 7 so the specific steps may vary depending on your version of Windows and your Windows settings Changing the baud rate of the modem 1 Con...

Страница 26: ...M1000 MP_v 2 0 0 Aug 11 2017 26 44 Confidential code before you can proceed 2 When the Add Hardware Wizard window pops out select Don t detect my modem I will select it from a list and click Next 3 Ch...

Страница 27: ...Robustel GoRugged M1000 MP User Guide RT_UG_M1000 MP_v 2 0 0 Aug 11 2017 27 44 Confidential 4 Choose the selected port that the modem wants to connect to the computer and click Next...

Страница 28: ...Robustel GoRugged M1000 MP User Guide RT_UG_M1000 MP_v 2 0 0 Aug 11 2017 28 44 Confidential 5 Click Finish to finish the modem installation 6 The new modem will be listed on the Modems tab...

Страница 29: ...ser Guide RT_UG_M1000 MP_v 2 0 0 Aug 11 2017 29 44 Confidential Set Maximum Port Speed 1 Double click Standard 33600 bps Modem and click Properties 2 Next click the Modem tab select 115200 as the Maxi...

Страница 30: ...ics Follow these steps to verify that the modem is installed properly and has been activated 1 Click the Diagnostics tab and click Query Modem It will pop up a Please Wait window in about 2 seconds 2...

Страница 31: ...ed to the modem as a modem initialization command before the Windows dial up The following are the steps about how to add the APN command 1 Click the Advanced tab 2 Enter the following commands in the...

Страница 32: ...stel GoRugged M1000 MP User Guide RT_UG_M1000 MP_v 2 0 0 Aug 11 2017 32 44 Confidential 3 Click Change Default Preferences 4 Choose 115200 as the port speed and None as the flow control and then click...

Страница 33: ...dow 6 Click OK to close the Modems window Adding Windows DUN The following are the steps about how to add the Windows Dial up Networking 1 In the Control Panel open Network and Sharing Center and clic...

Страница 34: ...new connection and click Next 4 Choose the Dial up option 5 Type 99 1 in the Dial up phone number box type the User name and Password in the corresponding boxes and click Connect Note User Name and P...

Страница 35: ...Robustel GoRugged M1000 MP User Guide RT_UG_M1000 MP_v 2 0 0 Aug 11 2017 35 44 Confidential 6 After the dialing up is completed the window is shown below...

Страница 36: ...Robustel GoRugged M1000 MP User Guide RT_UG_M1000 MP_v 2 0 0 Aug 11 2017 36 44 Confidential 7 Ping www google com to check whether GPRS connection has been established...

Страница 37: ...UND SIGN 163 0 02 2 DOLLAR SIGN 36 0 03 3 YEN SIGN 165 0 04 4 LATIN SMALL LETTER E WITH GRAVE 232 0 05 5 LATIN SMALL LETTER E WITH ACUTE 233 0 06 6 LATIN SMALL LETTER U WITH GRAVE 249 0 07 7 LATIN SMA...

Страница 38: ...PITAL LETTER E WITH ACUTE 201 0 20 32 SPACE 32 0 21 33 EXCLAMATION MARK 33 0 22 34 QUOTATION MARK 34 0 23 35 NUMBER SIGN 35 0 24 36 CURRENCY SIGN 164 ISO 8859 1 0 25 37 PERCENT SIGN 37 0 26 38 AMPERSA...

Страница 39: ...80 LATIN CAPITAL LETTER P P 80 0 51 81 LATIN CAPITAL LETTER Q Q 81 0 52 82 LATIN CAPITAL LETTER R R 82 0 53 83 LATIN CAPITAL LETTER S S 83 0 54 84 LATIN CAPITAL LETTER T T 84 0 55 85 LATIN CAPITAL LET...

Страница 40: ...ATIN SMALL LETTER V v 118 0 77 119 LATIN SMALL LETTER W w 119 0 78 120 LATIN SMALL LETTER X x 120 0 79 121 LATIN SMALL LETTER Y y 121 0 7A 122 LATIN SMALL LETTER Z z 122 0 7B 123 LATIN SMALL LETTER A...

Страница 41: ...he Signal Strength Indication table below for more information Is the antenna properly connected Refer to Chapter 2 5 No Carrier when trying to issue a voice communication Is the semicolon entered imm...

Страница 42: ...Ready DTE Data Terminal Equipment DTMF Dual Tone Multi frequency DTR Data Terminal Ready EMC Electromagnetic Compatibility EMI Electromagnetic Interference ETSI European Telecommunications Standards...

Страница 43: ...S Request to Send Rx Receive Direction SIM Subscriber Identification Module SMA Subminiature Version A RF Connector SMS Short Message Service TCP IP Transmission Control Protocol Internet Protocol TE...

Страница 44: ...User Guide RT_UG_M1000 MP_v 2 0 0 Aug 11 2017 44 44 Confidential Guangzhou Robustel Technologies Co Ltd Address 3rd Floor Building F Kehui Park No 95 Daguan Road Guangzhou China 510660 Tel 86 20 29019...

Отзывы: