![Robur 5001 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/robur/5001/5001_trouble-shooting-and-service-manual_1471556010.webp)
Trouble shooting manual – Robur gas fired wall heater model 5001
Version 1.2 - 12/06/2006
10/21
V = 120 V
Starting sequence (electrical)
STEP 1
1.
Check L1 – L2
(Supply 120 V, 60 Hz)
2.
Check M9
(Main fuse)
TROUBLE-SHOOTING STEP 1
Point 1 (L1-L2)
.
No voltage (120 V).
Check the electrical supply line, wirings and connections.
Point 2 (M9)
.
Fuse damaged.
Check the electrical supply line and replace the fuse.