SAFETY
Our automatic sieve-juicers are fitted with a
magnetic safety system.
The motor stops as soon as the body is opened.
To start up your appliance again, simply close the
body and press the green “on” button.
The single phase models (C 80 or C 120) are fitted
with a thermal cut-out which automatically stops
the motor if the machine is left on for too long or
overloaded.
If this happens, allow the machine to cool completely
before restarting.
20
The motor seal can be easily replaced without
having to remove the motor, so we strongly advise
you to ensure that it is in good condition.
TECHNICAL
SPECIFICATIONS
• WEIGHT
Net weight
Gross weight
C 80
21 kg
25 kg
C 120
40 kg
56 kg
C 200 • C 200 V.V.
41 kg
57 kg
• DIMENSIONS (in mm)
• NOISE LEVEL
The equivalent continuous sound level when the
automatic sieve is operating on no-loads is less than
70 dB (A).
• ELECTRICAL DATA
Single or three phase machine.
• WORKING HEIGHT
If the machine used is a C 80 model,
it is advisable
to install it on a stable work surface so that the
upper edge of the hopper is at a height of between
1.20 m and 1.30 m.
If the machine used is a C 120 or a C 200 model,
you are advised to set it up on a stable surface. In
this case, when the machine is installed on the
ground, there is no recommended working height to
be observed.
Never immerse the motor unit in water. Clean it
with a damp cloth or sponge.
Between each food processing operation or when
you have finished using the machine, place the two
receptacles under the appliance again.
Switch the appliance on and then pour 5 litres of
water into the hopper to wash the sieve.
For thorough cleaning, remove the tray, the body,
the sieve and the paddles and clean each of these
parts.
Speed
Power
Intensity
Motor
(rpm)
(watts)
(Amp)
C80
230 V single phase
50Hz
1500
1000 W
5.7
115 V single phase
60Hz
1800
1000 W
12.0
C120
230x400V tree phase 50Hz
1500
900 W
230 V : 3.6
400 V : 2.1
230 V single phase
50Hz
1500
900 W
5.5
115 V single phase
60Hz
1800
900 W
12.0
C200
230x400 V tree phase 50Hz
1500
1800 W
230 V : 7.5
400 V : 4.3
C200 V.V. 230 V single phase
50Hz 1500 a
1800 W
11.0
1800
A
530
B
580
C
360
A
860
B
1030
C
510
MAINTENANCE
• PADDLES
The paddles are made of rubber and are therefore
liable to wear. You should regularly check the
condition of the rubber and change the paddles
periodically to ensure that the finished product you
obtain is always of the same quality.
• MOTOR SEAL
The motor seal around the motor shaft should be
lubricated regularly using a food safe lubricant.
In order to keep the motor completely watertight, it
is advisable to check the motor seal regularly for
wear and tear and replace if necessary.
I M P O R T A N T
Check that your detergent is suitable for
cleaning plastic parts. Some washing agents
are too alkaline (e.g. high levels of caustic
soda or ammonia) and totally incompatible
with certain types of plastic, causing them to
deteriorate rapidly.