5 Surface-mounting
1. Attach to surface using two screws (not supplied) in the baseplate holes.
6 Installing in closed compartments
Requirements:
Enough space to allow natural heat transmission through surfaces.
Surfaces should not be insulated.
Air volume per light generator minimum 0.03 m³.
Ventilation holes per light generator with min. 20 cm² air inlet and min. 20
cm² air outlet.
Inlet and outlet ventilation holes opposite each other.
Max. ambient temperature 40ºC. (Measuring temperature: see
‘Troubleshooting’).
84 mm