background image

3

Inhalt - Inhoud

FÜR DEN BENUTZER ........................................................................................... 18

DEFINITION ................................................................................................................ 18

WICHTIGE HINWEISE ................................................................................................ 18

BEDIENUNG ............................................................................................................... 19

WARTUNG .................................................................................................................. 19

FÜR DEN INSTALLATEUR ................................................................................... 20

MONTAGE ................................................................................................................... 20

DIREKTER ABZUG NACH AUSSEN .......................................................................... 23

UMLUFTBETRIEB ....................................................................................................... 23

ELEKTRISCHER ANSCHLUSS .................................................................................. 24

VOOR DE GEBRUIKER ........................................................................................ 25

BESCHRIJVING .......................................................................................................... 25

BELANGRIJKE AANBEVELINGEN ............................................................................. 25

GEBRUIK ..................................................................................................................... 26

ONDERHOUD ............................................................................................................. 26

VOOR DE INSTALLATEUR .................................................................................. 27

INSTALLATIE ............................................................................................................... 27

DIRECTE AFVOER NAAR BUITEN ............................................................................ 30

AFVOER BIJ CIRCULATIEKAP .................................................................................. 30

ELECTRISCHE AANSLUITING ................................................................................... 31

All manuals and user guides at all-guides.com

Содержание OPEN 610

Страница 1: ...2108 Instructions Booklet Mode d emploi Bedienungsanleitung Gebruiksaanwijzing Open 610 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...N DIRECTLY OUTDOORS 8 EVACUATION BY RECYCLING 9 ELECTRICAL CONNECTION 10 POUR L UTILISATEUR 11 DÉFINITION 11 Recommandations Importantes 11 UTILISATION 12 ENTRETIEN 12 POUR L INSTALLATEUR 13 INSTALLATION 13 EVACUATION DIRECTE VERS L EXTÉRIEUR 15 EVACUATION EN RECYCLAGE 16 RACCORDEMENT ÉLECTRIQUE 17 All manuals and user guides at all guides com ...

Страница 3: ...DIREKTER ABZUG NACH AUSSEN 23 UMLUFTBETRIEB 23 ELEKTRISCHER ANSCHLUSS 24 VOOR DE GEBRUIKER 25 BESCHRIJVING 25 BELANGRIJKE AANBEVELINGEN 25 GEBRUIK 26 ONDERHOUD 26 VOOR DE INSTALLATEUR 27 INSTALLATIE 27 DIRECTE AFVOER NAAR BUITEN 30 AFVOER BIJ CIRCULATIEKAP 30 ELECTRISCHE AANSLUITING 31 All manuals and user guides at all guides com ...

Страница 4: ...t reference AH 4020 F1 that you can order from your Fitter Important Recommendations In a kitchen heated with an appliance connected to a chimney for example stove cooker etc install the recycling version of the hood and check that there is adequate room ventilation fresh air Preferably use the cooking areas at the back of your appliance Operate the hood for a few minutes before starting cooking U...

Страница 5: ...uit breaker off Grease filter The metal grease filter should be cleaned every two months with normal usage and can be cleaned in a dishwasher or by hand using a mild detergent or liquid soap Proceed as follows see fig 2 fig 3 Open the auvent to the end stop Remove the filters one at a time pushing the handle towards the rear of the hood When replacing ensure that the handle faces outwards NOTE new...

Страница 6: ...our guarantee is applicable exclusively and soley to appliances which have been installed and connected by yourself in accordance with the requirements of ordinances in force You will be responsible if this condition is not respected INSTALLATION The hood must always be fitted above the center of the cooker hob The minimum distance between the top of the cooker hob and the bottom of the hood shall...

Страница 7: ...at the front left inside fig 7 to completely remove theauvent 2 Drill the starter holes inside the facade using the drilling template provided for this purpose 3 Place the auvent on the panel aligning the holes and screw in using the screws provided Do not put it back on the hood before installation on the wall Wall mounting Attach the hood by its suspension hooks to the support lugs attached to t...

Страница 8: ...t be in accordance with Unified Technical Document DTU n 61 1 Connection fittings must be made in accordance with standard practice and respect safety conditions and under no circumstances shall the evacuation duct discharge into the attic Flues used as smoke ducts shall not be used EVACUATION DIRECTLY OUTDOORS In this case it is recommended that the telescopic suction cup reference AH 4009 F1 wit...

Страница 9: ...mbled Lift the auvent by its lower part and insert the two upper guide slides in their respective housings Pivot the auvent downwards inserting the two lower guide slides and tilt the auvent until it closes Reopen the auvent to make sure that it operates correctly and to check the presence of the stop at full opening Depending on the weight of the facade the friction resistance of the auvent may b...

Страница 10: ...nstallation shall comply with standard NF C 15 100 TECHNICAL DATA Power supply voltage 230 V 50 Hz Total connection power 350 W Motor 2 x 135 W Lighting 2 x 40 W Number of speeds 3 Evacuation duct diameter 100 or 120 mm Hood width 598 mm Hood depth 270 360 mm Hood height 350 mm This hood complies with EEC directives 76 889 and 82 499 related to radioelectric disturbances ordinance dated August 19t...

Страница 11: ...Kit de recyclage AH 4020 F1 Recommandations Importantes Dans une cuisine chauffée avec un appareil raccordé à une cheminée ex poêle cuisinière il faut installer la hotte en version recyclage et s assurer d une ventilation suffisante de la pièce air frais Utilisez de préférence les zones de cuisson arrière de votre appareil Faites fonctionner la hotte quelques minutes avant le début de la cuisson P...

Страница 12: ...tre anti graisses Le filtre anti graisses est l élément assurant une part importante de l efficacité de la hotte il retient les vapeurs grasses et les poussières Il est indispensable de le changer régulièrement Procédez comme suit fig 2 fig 3 Lavez ces filtres avec un produit détergent du commerce au maximum tous les deux mois Grâce à leur dimension compacte vous pouvez également les laver dans vo...

Страница 13: ...es seul compétent pour l installation et le raccordement des appareils C est pourquoi notre garantie s applique uniquement et exclusivement aux appareils dont l installation et le raccordement auront été effectués par vos soins conformément aux dispositions des décrets en vigueur Le non respect de cette condition engagerait la responsabilité de l installateur INSTALLATION La hotte doit toujours êt...

Страница 14: ...e semblable à celle des meubles de la cuisine et fixée sur l auvent façade fournie par l installateur des meubles 1 Ouvrir entièrement l auvent et actionner la touche de verrouillage située à l intérieur et à l avant gauche fig 7 pour retirer complètement l auvent 2 Percez les avant trous sur l intérieur de la façade en utilisant le gabarit de perçage prévu à cet effet 3 Placez l auvent sur le pan...

Страница 15: ... arrière Ces positions sont à respecter impérativement suivant l utilisation Raccordement à un conduit individuel ou collectif Raccordez la hotte à un conduit cheminée non utilisée individuel ou collectif en utilisant des éléments de raccordement et tuyaux en matière ininflammable Les hottes utilisées en version évacuation ne doivent pas contrarier les ventilations existantes ainsi que les extract...

Страница 16: ... recyclé est rejeté par les ouies situées à la partie supérieure de la façade de la hotte Dans ce cas l auvent de la hotte doit impérativement être tiré à fond pour dégager entièrement les ouies de la façade Remontage de l auvent tôle et façade assemblées Prende l auvent par sa partie inférieure et introduire les deux guides glissières supérieurs dans leurs logements respectifs Faire pivoter l auv...

Страница 17: ...3 mm minimum L installation doit être conforme à la Norme NFC 15 100 CARACTERISTIQUES TECHNIQUES Tension d alimentation 230 V 50 Hz Puissance totale au branchement 350 W Moteur 2 x 135 W Eclairage 2 x 40 W Nombre de vitesses 3 Ø buse évacuation 100 ou 120 mm Largeur de la hotte 598 mm Profondeur de la hotte 270 360 mm Hauteur de la hotte 350 mm Cette hotte est conforme aux directives 76 889 CEE et...

Страница 18: ...s C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträglichkeit und den Richtlinien 93 68 EWG zur CE Kennzeichnung Dit apparaat voldoet aan de Europese Laagspanningsrichtlijn 72 ...

Отзывы: