background image

SECTION

 

No 

TITLE 

ASSEMBLY SYNOPSIS: IMPORTANT INFORMATION / CONSIDERATIONS 

 

 

PARTS LIST 

Most components should have a ‘D’ code punched into their metal surface. Identify and separate 
all like for like components prior to assembly. The ‘parts list’ also separates parts into the various 
sections shown below. Parts can also be identified by their profile pictures and stated lengths etc.. 

BASE 

Base dimensions and recommendations. Ensure that your base is level as this will make assembly 
of the building, especially the glazing of the roof much more straight forward.  

PREPARATION 

Tools required. IMPORTANT: Use WD40 or similar in the glazing bar channels and insert the black 
glazing rubber prior to frame assembly.  

 

SIDES 

Take the side glazing bars ‘D066’ with the rubber inserted and the diagonal braces ‘D103’, use 
10mm bolts to join them to the gutter and 15mm bolts to the cills (note how the head of the bolts 
slide into each glazing bar during construction). 

FRONT  

Again ensuring that the gable framework is rubbered-up follow the diagrams to assemble each end 
of the building. Make sure that you have inserted the extra bolts utilised in sections 4, 5  and 10. 
On the roof and side corner bars not every rubber channel will require rubber. 

REAR 

JOINING THE 

FOUR SIDES  

Take the two sides (1) and both gables (2 & 3) and join them together on your base. It is a good 
idea to tie some ladders to the sides to support them if you do not have anyone to hold them for 
you. 

ROOF 

Attach the ridge and then the rubbered-up roof bars ensuring that they are fully butted up to the 
ridge and down onto the gutter. If you have cresting then it is a good idea to fit it before glazing, 
see section (14). 

DOOR 

Construct the door using the diagrams and then leave to one side ready for attachment in section 
(10). 

7a 

VENT 

Once the vent is glazed add silicone to the vent sides and top. Stand the vent/s on their hinge (vent 
top) and then leave the silicone to set.   

7b 

VENT SLAM 

The slam bar ‘D079’ can be moved up and down between the roof glazing bars so that it can be 
butted down onto the pane of glass beneath, the autovent will be attached to it later on (9). 

 

 
 

GLAZING 

Layout the bar capping and covers around the building like a sundial checking that all is present 
and correct. You can also place the roof capping in the gutters so they are closer to hand. The 
glass in the sides has to bevel on the black separator strip which is on top of the 305mm high glass 
base panels. This bevelling action allows the glass to tuck underneath the gutter canopy. Use the 
capping and the self tapping screws to then hold the glass in place. The covers then enclose the 
screw heads giving a neat finish. A top tip is to not attach the door post capping (D766/D767) until 
you have fitted the door runner and threshold (10) to give you more room to manoeuvre. It is a 
good idea to glaze two roof sections first to ensure the building is square followed by two side sec-
tions to ensure the building isn't leaning,   

VENT  

ATTACHMENT 

Take the assembled vent and slide the vent hinge ‘D866’ into the end of the ridge allowing the vent 
to pivot open and closed. Vent stops go either side of the vent to stop any lateral movement (so 
insert stop / vent / stop). Attachment of the Bayliss XL autovents.  

10 

DOOR  

ATTACHMENT 

Use the bolts inserted in section (2) to attach the upper door track. The lower door runner ’D860’ 
and ramp threshold ‘D087’ push down and lock together.   

11 

ANCHORING 

DOWN 

Now that the greenhouse is finished and the door and vent/s are operating without interference 
then you need to anchor the building down using 2” rawl plugs and screws. Use a 7mm masonry 
bit in a hammer drill to create the holes. 

12 

OPTIONAL 

LOUVRE 

They attach to the building during the glazing process (8) like a piece of glass with a black separa-
tor above and below them. 

13 

 

OPTIONAL 
SHELVING 

 

Robinsons integral cantilever shelving attaches to the inside of the greenhouse frame using either 
square head bolts (for each shelf insert two into each side glazing bar ’D066’ during construction of 
the sides (1)) or use rectangular ‘crop head’ bolts which can be fitted retrospectively (both sets of 
bolts accompany the shelving). 2’ shelves can also be fitted onto the rear glazing bars ‘D057’ so 
again you may wish to pre-load them with two bolts or more. This system allows the height of the 
shelf to be set at an operator specific height, note it is possible to get up to three sets of shelving 
on each side and rear. The aluminium shelf slats come in three lengths; (2’): 620mm ‘D2001’, 
(4’):1240mm ‘D2002’ and (6’):1860mm ’D2003’. These slats can combine to create any length of 
staging required, i.e. 4’+6’ = 10’ etc...    

14 

FINISHING 

TOUCHES 

Now that the main body of the structure is complete you can add; ridge caps, downpipe fittings, 
eave bungs. Images showing cresting and finial attachment, this is often easiest to do after section 
(5) rather than using the vent apertures later on (i.e. before glazing).  

Содержание Rowton

Страница 1: ...NOMINAL SIZE A mm B mm 4 x 6 1366 2012 4 x 8 2632 4 x 10 3252 4 x 12 3872 4 x 4 1392 4 x 2 772...

Страница 2: ...most solid foundation for your greenhouse IMPORTANT Do not fix your building down until the building is fully assembled including glazing Avoid placing your greenhouse under trees or in other vulnera...

Страница 3: ...he sides has to bevel on the black separator strip which is on top of the 305mm high glass base panels This bevelling action allows the glass to tuck underneath the gutter canopy Use the capping and t...

Страница 4: ...3757 1 D1133 714 4 6 8 10 RUBBER 1000 1m 6 9 12 15 D072 1277 1 2 3 D1047 657 1 0 0 D866 639 1 2 3 4 D863L 613 1 2 3 4 D863R 613 1 2 3 4 D862 593 1 2 3 4 D079 PLUS FLUFF 590 1 2 3 4 D114 N A 2 4 6 8 D...

Страница 5: ...3 90 2 D150 N A 1 D222 B 590 1 D204 L R B 1 1 D845 2 D312 2 ANY OTHER PARTS IN YOUR DOOR PACK ARE REDUNDANT ON THIS MODEL Section Ref Part No Section Size mm 4 6 4 8 4 10 4 12 4 4 4 2 Section Ref Part...

Страница 6: ...use including its 4mm glass Give yourself enough room around your base to allow for fitting the glass and any on going maintenance cleaning A slab base which is larger than the greenhouse is the ideal...

Страница 7: ...ertion The frame is assembled by feeding square headed bolts either 10mm or 15mm in length into the slots on glazing bars and then locating those bolts through holes in purlings and cills etc Twist in...

Страница 8: ...066 1676 10 D103 1787 4 D174 8 M6 10mm 10 M6 15mm 14 M6 NUT 24 12 X 2 Rubber 1000 34 Part No mm Quantity D015 3137 2 D022 3134 2 D066 1676 8 D103 1787 4 D174 8 M6 10mm 8 M6 15mm 12 M6 NUT 20 10 X 2 Ru...

Страница 9: ...TRANSIT BOLT ON DIAGONALS 15mm D103 15mm D066 10mm D066 You may wish to pre load the side glazing bars D066 with square head 10mm bolts for any shelves purchased rather than use crop heads retro spec...

Страница 10: ...366 1 D1131 714 1 D1132 714 1 D1141 1703 2 D1130 D057 D057 D048 D048 D1132 D1141 D1141 D1131 Part No mm Quantity D174 4 M6X10 8 M6X15 12 M6NUT 20 D111 1 D227 15 5m 10mm 15mm 15mm 15mm 15mm 10mm 15mm 1...

Страница 11: ...11 D057 D1131 D048 D1130 D174 D1141 D057 D1130 D111 D1132 D1131 D750 D048 D1141...

Страница 12: ...8 M6X15 10 M6NUT 18 D111 1 D227 15 5m D1130 D057 D057 D048 D048 D1132 D1141 D1141 D1131 10mm 15mm 15mm 15mm 15mm 10mm 15mm 15mm 15mm 15mm 10mm 10mm 10mm 10mm 15mm 15mm 15mm 15mm You may wish to pre lo...

Страница 13: ...13 D057 D1131 D048 D1130 D174 D1141 D057 D1130 D1131 D048 D1141 D111 D1132 D1131...

Страница 14: ...14 EQUAL...

Страница 15: ...an D002 3137 1 D1133 714 8 RUBBER 1000 12 10 16 Part mm Quan D001 2517 1 D1133 714 6 RUBBER 1000 9 8 12 Part mm Quan D044 1897 1 D1133 714 4 RUBBER 1000 6 6 8 4 4 Part mm Quan D072 1277 1 D1133 714 2...

Страница 16: ...PACK N A 24 D909 247 x 812 pane D909 247 x 812 pane 8 D761 D233 D233 A B A B D061 D233 D233 D909 247 x 812 pane D909 247 x 812 pane D765 D764 D760 D762 D347 lock D764 1714 1 D763 D156 strike D765 1714...

Страница 17: ...17 D225 D909 247 x 812 pane D909 247 x 812 pane C C D909 247 x 812 pane D233 D225 8 D060 D062 E F E F P053 G H G 7 7 H D840B...

Страница 18: ...L D866 639 1 D863L 613 1 D863R 613 1 D862 593 1 Part No mm Quantity D220 PLUS FS6060 SCREW N A 2 D205 N A 2 SY BOLM6X11 10 4 SYNUTM6 M6 4 8 X 12 S T FS6017 10 2 Part No mm Quantity 8 x 19 S T FS6018 1...

Страница 19: ...19 D862 D862 D863L 2 2 2 2 2 FLIP VIEW D119 CUT 6mm SILICONE...

Страница 20: ...20 D114 D079 FLIP VIEW D079 PLUS FLUFF 590 1 D114 N A 2 Part No mm Quantity SY BOLM6X11 10 2 SY BOLM6X15 15 2 SYBOLM6 X11CROP 10 2 SYNUTM6 N A 4 Part No mm Quantity D114...

Страница 21: ...o place the roof cappings in the gutters so they are closer to hand The glass in the sides has to bevel on the black white separator strip see right which is on top of the 305mm high glass base pan el...

Страница 22: ...1 1906 D1060 50 D1135 724 D813 1675 D766 1773 D834 1660 D1134 722 D1136 PLASTIC OR ALUM 724 D825 1660 D826 1677 D827 1832 D767 1773 D1059 50 D826 D813 D825 D812 D1136 D1134 D1136 D1134 D1136 D1135 D11...

Страница 23: ...D904 T 305 X 1374 4 D909 C 247 X 812 4 D902 X ANGLE 4 D1137 Y APEX 1 D1138 Z APEX 1 D222 B 590 long 1 D101 ROSEPS 610 long inc 305mm cuts 10 12 14 16 20 2 3 1 1 3 8 D1139 U 610 X 132 1 1 1 2 3 4 R M...

Страница 24: ...here is not enough room for the D220 stops to be fitted in the ridge Instead the plastic ridge D203 end cap acts as the stop see section 14 On the back of the D203 one of the upper protrusions may nee...

Страница 25: ...25 D079 D862...

Страница 26: ...26 Part No mm Q D864 590 1 D082 1270 1 D081 1270 1 Part No mm Q D163 90 2 D150 1 D845 2 SY BOLM6X15 8 SYNUTM6 8 D800 PLASTIC 1 588 D766 D767 D845 D845 D163 D845 D057 D057...

Страница 27: ...864 D081 D082 15 4 N A 4 D150 D864 D800 X ray D864 D800 Note D800 is a plastic infill to aid glazing it can be removed after the pane above the doors has been installed if you wish Its colour may not...

Страница 28: ...28 D860 1 D087 1 Part No Quantity D860 D087 D860 D087...

Страница 29: ...29 D312 2 D204L B 1 D204R B 1 Part No Quantity D222 B 590 D204R D1132 D312 D222 B D1137 D1060 D1059 D1060 D1059 X ray D1137 D222 B D800 B...

Страница 30: ...30 O7mm...

Страница 31: ...D168L D168R handle 552 552 1 1 D165 612 2 D166 552 2 FS6013 12 4 Part No mm Quantity INTERNAL VIEW D165 D165 D166 D166 D168L D168R D165 PINCH ALL GLASS RETAINERS BEFORE GLAZING D729TG 100 x 525 panes...

Страница 32: ...D2002 1240mm D2003 1860mm D2002 1240mm Example 2 x 4 3 slat shelves ST0304 8 run D066 D048 D048 IMPORTANT Please make sure when deciding on your shelving heights that the louvre handle or optional aut...

Страница 33: ...m Quantity D2001 620 3 D2013 285 2 D2014 370 2 D2021 N A 6 1 x 2 3 SLAT QUANTITIES SYBOLM6 X11 10mm 8 SYBOLM6 X15 15mm 2 SYNUTM6 M6 nut 10 SYBOLM6 X11CROP 10mm 4 IMPORTANT Please make sure when decidi...

Страница 34: ...34 D207 D841 D119 SILICONE D119 S I L I C O N E D211 D211 D203 D201 D202 D206 D048 D048 D048 D208 CUT D119 S I L I C O N E D214...

Страница 35: ...QUAL End finials need to be pinched onto ridge using DV282 grub screws Depending on your ridge length a half cresting may need to be cut or and some spacer bar DV281 cut into two equal sections Each f...

Страница 36: ...y errors or have any constructive comments regarding the manual please email james spooner greenhousepeople co uk and I will make the necessary amendments Whilst the information contained in this book...

Отзывы: