3
Push in the control knob slightly and turn it clockwise to the OFF position.
Depressing and rotating the knob clockwise from the full-on position brings you firstly to the 3 position. At this setting the centre
two radiants are bright and the outer two radiants are on low. The two outer radiants are extinguished by turning the tap knob to
the halfway 2 position. This position gives approximately half the full heat of the fire. Rotating the knob further in a clockwise
direction brings you to the 1 position. This gives you about 1/4 of the full heat of the fire and is the most economical setting.
(A) FRONT PANEL: The front panel is a one piece assembly and can be removed very easily. This is done by lifting the front panel
upwards to clear the lower support pins and then pulling outwards and downwards from the fire. When replacing care must be
taken to ensure that the top slots are correctly engaged before sliding the panel upwards and back into position on the lower
support pins.
N.B.: The four pins that support the front panel are fitted in the front of the slots in the metal case.
(b) RADIANT CHANGING: Before changing the radiant ensure that the fire is cold. Remove the front panel as described above.
The radiant is then removed by lifting upwards and outwards. When replacing the radiant ensure that the bottom of the radiant
is seated down and behind the raised front edge The makers part number for the radiant is 995 971 and the G.C. number is
154 371.
(c) REPLACING BATTERY (Electronic ignition): Remove front panel (a) above. Remove battery and replace with a new one.
Do not attempt to clean the heater while it is warm. Generally cleaning can be done with a damp soapy cloth followed by polishing
with a soft cloth.
Abrasive cleaners should never be used. The teak or rosewood effect of the Firegem Visa 2 Deluxe should be wiped with a damp
cloth only. Do not apply furniture polish to this case.
TO TURN OFF
LIGHTING WITH A MATCH OR TAPER
ECONOMY USE
CLEANING
SIMPLE MAINTENANCE
CONTROL KNOB
RADIANT PICTURE
SETTING
1
Centre 2 radiants on low
2
Centre 2 radiants on full
3
Centre 2 radiants on full, outer 2 on low
4
All 4 radiants on full
NOTE
The control knob should be pushed in slightly
before turning and always set to one of the stated
positions. Turn the control knob to the desired
setting.
Note also that lighting instructions are provided
inside the lift up flap of the bezel on the top right
side of the fire.
Piezo Spark Ignition (2 clicks)
Ignition is via a piezo electric spark generator and is energised
during operation of the tap. It does not need batteries or an
external electrical supply.
The gas can be lit with a match if necessary. First, remove the
front panel (see (a) below) then light the match and place near
the pilot, and then turn the gas tap to the pilot position, press
down and light the pilot. Hold down for a further 10 seconds
before releasing, the pilot should still remain lit. Replace the front
panel before turning the gas tap knob to a higher position.
Battery Spark Ignition
Ignition is by an electronic spark generator powered by a
PP3 battery and operates to light the pilot. In the event of
failure of the electronic spark due to low battery etc. the fire
can be lit with a match or taper.
First remove the front panel (see (a) below). Light the match
or taper, place it near the pilot, turn the knob to the PILOT
position and press down to light the pilot. Keep the knob
pushed in for 10 seconds before releasing. The pilot should
remain lit.
Replace the front panel before turning the control knob to a