background image

 

 

Pre-Installation 

Ducting 

The method of ducting should be carefully considered before installing the rangehood. 150mm round ducting should be 

used in conjunction with this model rangehood. Alternatively, this rangehood can be operated in recirculation mode. 

Installation position 

 

 

A.

 

Minimum

 height from the hob surface to the underside face of the rangehood: 

650mm

Note

: If the instructions for the hob specify a greater distance, this greater distance must be used. Any installation 

above 

750mm

 will compromise performance. 

B.

 

Vertical height from bottom of Rangehood to Fixing Plate mounting screws 

323mm

C.

 

Distance between mounting screw holes on Fixing Plate 

100mm. 

 

 

Содержание RWC60XCOM

Страница 1: ...Installation and Operating Instructions Model Numbers RWC60XCOM RWC90XCOM Description Wall Canopy Rangehood Pictured RWC60XCOM ...

Страница 2: ...uctions and your proof of purchase along with any other important documents about this product for future reference Due to continual product development Shriro reserves the right to alter specifications or appearances without notice Important Safety Instructions 1 Appliance Details 2 Pre Installation 3 Installation 4 5 Operating Instructions 6 Cleaning and Maintenance 6 Replacing the Lights 7 Warr...

Страница 3: ...oking 13 It is recommended to leave the range hood in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours and odours 14 Turn off the range hood when not in use 15 Do not use the range hood if it is damaged especially the supply cord and the case 16 Do not immerse the range hood in liquid 17 The exhaust air must not be discharged into a flue which i...

Страница 4: ... this information booklet accessible for further consultations The appliance has been designed to exhaust cooking fumes externally Before installation please ensure that the following have been supplied and that the tools listed below are readily available Contents of packaging 1 x Rangehood 1 x Packet of fasteners and wall plugs 1 x Chimney pieces upper and lower 2 x Chimney bracket 1 x Fixing pl...

Страница 5: ...ated in recirculation mode Installation position A Minimum height from the hob surface to the underside face of the rangehood 650mm Note If the instructions for the hob specify a greater distance this greater distance must be used Any installation above 750mm will compromise performance B Vertical height from bottom of Rangehood to Fixing Plate mounting screws 323mm C Distance between mounting scr...

Страница 6: ...to ensure bracket is level Tighten screws 2 Mark the position of the decorative chimney at the ceiling and wall Cut the cornice moulding away if required to enable the chimney to sit flush against the wall and ceiling 3 Only if ducting Mark and cut out the hole in the ceiling wall to fit the ducting 160mm diameter max Warning Chimney depth is 172mm Ensure no part of the hole is greater than 170mm ...

Страница 7: ...justment is required in step 9 8 Connect to the power supply and switch on the power to the canopy hood Check the function of the canopy hood Connect and secure the ducting use duct tape if required 9 Place the two chimney pieces onto the canopy top and secure the lower part to the canopy sides Extend the upper chimney to the ceiling and secure in place with two screws supplied Recirculation mode ...

Страница 8: ...nts cleaning should be carried out frequently Warning A buildup of oil may occur if the compact canopy is not cleaned regularly Filter Maintenance To maintain efficiency the filters should be removed regularly approximately monthly and washed using hot soapy water or the dishwasher Some discolouration of the filter frame may occur if washed in the dishwasher Rangehoods fitted with charcoal filters...

Страница 9: ...lugged from the wall socket Ensure that the light is cool before touching Remove the aluminium filter Press the light face and turn anti clockwise to remove Replace with an identical light o Type GU10 LED o Max Wattage 2 x 3W o Voltage Range 220 240V AC o ILCOS D Code DR 3 65 1B H GU10 46 50 Replace the aluminium filter ...

Страница 10: ... 1800 628 577 Email customercare shriro com au www robinhood com au Attention Customer Services Manager Warranty exclusions 1 The warranty does not apply where in Shriro s opinion The defect is caused by misuse wear and tear dirt fire or accidental damage The product has been repaired or serviced by an unauthorised person The product was not installed in accordance with our instructions The produc...

Отзывы: