background image

WALL/CEILING PREPERATION 

RECIRCULATION 
For recirculation, do not cut 170mm hole and purchase a charcoal filter. 
For other accessories, parts and service, please contact your local supplier or approved service agent 
 

DUCTED 

For ducted installation, it is recommended you use 150mm diameter rigid / semi rigid ducting this 
will require a 170mm hole in the ceiling / wall. 
 
Before drilling any holes check the area behind the surface to be drilled is clear of any electrical 
cables, pipes etc.  

 
 
 
 
 
 
 
 
 
 
 
 

NOTE

: Fixing to a solid stud is recommended. 

 

 
 

1.

 

Pre  drill  pilot  hole  3mm  diameter  at 
dimensions C and B. 

       B=305mm and C=220mm. 

2.

 

Loosely  fix  the  mounting  screw  and  2  x 
washer in position, check with a spirit level 
across the washers to ensure they are level. 

3.

 

Mark  the  position  of  the  decorative 
chimney  at  the  ceiling  and  wall.  Cut  the 
cornice  moulding  away  if  required,  to 
enable  the  chimney  to  fit  flush  against  the 
wall and ceiling. 

4.

 

Mark  and  cut  out  the  hole  in  the  ceiling  / 
wall to fit the ducting. (170mm dia.) This is 
positioned centrally above the canopy hood 
and  85mm  from  the  wall.  (For  ceiling 
option) 

5.

 

Using  the  screws  supplied,  fix  the  chimney  bracket  to  the  wall,  100mm  below  the  ceiling 

 

checking that it is aligned with the hood. 

6.

 

Remove the protective plastic covering from all parts including the filters. Fit the canopy hood 

 

on the mounting screws, tighten  screws. Plug in the power cord to the supply and check the 

 

function of the canopy hood. Connect and secure the ducting (use duct tape if required).  

7.

 

Assemble  the  top  chimney  to  the  chimney  bracket  and  fix  using  the  screws  supplied,  then 

 

assemble the bottom chimney to the canopy hood and fit into the glass recess. 

8.

 

Remove transport tape that holds the oil cup in place under the motor unit and fit the filters. 

DIA 170

85 TO C

100

DIM  B

DIM C

DIM  

A

SEE NOTE

L

 

MAINTENANCE 

Particular  care  must  be  taken  with  the  grease  filters  which  must  be  periodically  cleaned  (at  least 
every two months).  Remove the grease filters and wash them either by hand using hot soapy water 
or  in  the  dishwasher  using  mild  detergent.  Note-  some  discolouration  of  the  frame  may  occur. 
Caution:  Never  use  abrasive  or  oil  based  liquid  cleaners.    To  clean  the  stainless  steel  and  glass 
components  of  the  appliance  use  mild  detergent  and  warm  water.  In  areas  of  high  humidity  and 
coastal environments cleaning should be carried out frequently.

 

In  the  case  of  charcoal  filters,  these  are  disposable  items  and  it  is  recommended  that  these  be 
replaced every 2-4 months depending on the use of the canopy hood. 
For  other  accessories,  parts  and  service,  please  contact  your  local  supplier  (Refer  to  the  Warranty 
Certificate).

 

 

LIGHT REPLACEMENT  

(

Halogen bulb 12 Volts/10 Watt

1.

 

Switch off the power to the canopy hood and allow the bulb to cool. 

2.

 

Use a small bladed screwdriver to prise off the light cover, taking care not to  

  damage the surrounding material. 
3.

 

Use a cloth to remove the bulb. 

4.

 

Replace with a new bulb using a cloth. 

Do not touch the bulb with fingers

5.

 

Snap the cover back in place. 

 

WARNINGS

 

 

This  canopy  hood  is  not  intended  for  use  by  young  children  or  infirm  persons  without 
supervision. 

 

Young children should be supervised to ensure that they do not play with the canopy hood. 

 

There shall be adequate ventilation of the room when the canopy hood is used at the same time 
as appliances burning gas or other fuels. (A partial vacuum in the room could result in too high a 
concentration of gas in the air) 

 

You must read the details concerning the method and frequency of cleaning (see maintenance). 

 

There is a fire risk if cleaning is not carried out in accordance with the instructions. 

 

Do not flambé under the canopy hood. 

 

Exhaust  air  must  not  be  discharged  into  an  existing  flue  which  is  used  for  exhausting  fumes 
from appliances burning gas or other fuels 

 

The  minimum  distance  between  the  hob  surface  and  the  filters  of  the  canopy  hood  shall  be 
650mm. 

 

Attention should be given to ensure that any applicable regulations concerning the discharge of 
exhaust air is fulfilled. 

 

If the supply cord of this equipment is damaged it must only be replaced by the manufacturer, its 
service agent or similarly qualified person in order to avoid a hazard. 

 

 

 

ISO 9001/2000 certification

 

New Zealand: Robinhood Ltd 

Tel: 0800 760 667  Fax: 0800 276 246  
Email: [email protected] 
www.robinhood.co.nz 

Australia: Robinhood Australia Pty Ltd ACN  

Tel: 1800 648 556  Fax: 1800 628 577 
Email: [email protected] 
www.robinhood.com.au 

 

RECOMMENDED DUCTING 

SYSTEM FOR RANGEHOODS

 

 

Отзывы: