background image

RGT - SERIES 

APPROVED                                    Page 3 of 6 
ISSUE: C 
ECN 07 033 

 

ROBINHOOD GRANGE II 

 

RGT6WH, RGT6BL, RGT6SS GRANGE II 600 – 3 SPEED 
RGT9WH, RGT9BL, RGT9SS GRANGE II 900 – 3 SPEED 

 

ITEM 

DESCRIPTION 

 

PART No. 

 

 

 

WHITE 

BLACK 

S/STEEL 

Body Wrapper 

 

 

 

2 & 9  Corner Plastic Family 

101150WH 

101150BL 

101150BL 

Filter Channel Clear 

103709 

103709 

103709 

Filter Spring  

101221 

101221 

101221 

Filter Aluminium 288 x 
362.5 

103793 

103793 

103793 

 

Filter Charcoal 288 x 
362.5 

103793C 

103793C 

103793C 

Recirculating Cover 

103854WH 

103854BL 

103854BL 

3 Speed Switch 
Assembly 

103417WH.SP  103417BL.SP  103417BL.SP 

Diffuser 

101112 

101112 

101112 

10 

Twin Motor Housing 

103853 

103853 

103853 

11 

Recirculating Duct 

103915 

103915 

103915 

12 

Switch Cover 600mm 

103921 

103921 

103921 

12 

Switch Cover 900mm 

103848 

103848 

103848 

13 

Duct Blanking Disk 

103924 

103924 

103924 

14 

Lamp 40Watt Candle 
Shape 

102722 

102722

 

102722

 

15 

Duct Adaptor 

110030 

110030 

110030 

 

 

 

 

 

 

 

 

 

 

 

Содержание RGT6WH

Страница 1: ...RGT SERIES APPROVED Page 1 of 6 ISSUE C ECN 07 033 GRANGE II RANGE HOOD MODEL RGT6WH RGT6BL RGT6SS RGT9WH RGT9BL RGT9SS SERVICE MANUAL ...

Страница 2: ...RGT SERIES APPROVED Page 2 of 6 ISSUE C ECN 07 033 RGT6WH RGT6BL RGT6SS RGT9WH RGT9BL RGT9SS ...

Страница 3: ...21 5 Filter Aluminium 288 x 362 5 103793 103793 103793 Filter Charcoal 288 x 362 5 103793C 103793C 103793C 6 Recirculating Cover 103854WH 103854BL 103854BL 7 3 Speed Switch Assembly 103417WH SP 103417BL SP 103417BL SP 8 Diffuser 101112 101112 101112 10 Twin Motor Housing 103853 103853 103853 11 Recirculating Duct 103915 103915 103915 12 Switch Cover 600mm 103921 103921 103921 12 Switch Cover 900mm...

Страница 4: ... 1 10 LIFT MOTOR HOUSING FRONT EDGE DRAW POWER CABLE THROUGH BACK 1 11 REMOVE MOTOR HOUSE FROM BODY 1 12 REASSEMBLE RANGEHOOD IN REVERSE TO PROCEDURE ABOVE TAKING CARE TO PULL AS MUCH OF THE POWER CORD OUT OF THE BODY AS POSSIBLE 1 13 TEST TO ELECTRICAL SAFETY STANDARDS SECTION 2 SWITCH REPLACEMENT 2 1 REMOVE THE SWITCH BRACKET 2 2 REMOVE SWITCH ASSEMBLY FROM THE SWITCH BRACKET 2 3 REMOVE THE LID ...

Страница 5: ...HOUSING AS PER THE INSTRUCTIONS IN SECTION 1 3 2 REMOVE THE TOP COVER 3 SCREWS 3 3 REMOVE THE CABLES FROM THE CONNECTOR BLOCK 3 4 PULL OUT POWER CORD AND RECONNECT NEW CORD 3 5 CARRY OUT EARTH TEST BEFORE CONNECTING TO POWER 3 6 REPLACE IN REVERSE ORDER AS ABOVE 3 7 TEST TO ELECTRICAL SAFETY STANDARDS ...

Страница 6: ...RGT SERIES APPROVED Page 6 of 6 ISSUE C ECN 07 033 WIRING DIAGRAM ...

Отзывы: