6F -SERIES
APPROVED Page 5 of 7
ISSUE: C
ECN2802
TO REPLACE POWER CORD
1
DISCONNECT FROM POWER SUPPLY
2
REMOVE UNIT TO SUITABLE WORK AREA
3
REMOVE FILTERS
4
REMOVE GLASS DISFFUSERS BY UNDOING SCREWS AND
REMOVING RETAINERS, THEN SLIDE DIFFUSERS IN
TOWARD CENTRE OF UNIT TO CLEAR
5
REMOVE LAMPS
6
UNSCREW AND REMOVE LAMP HOLDERS
7
REMOVE 7 SMALL SCREWS TO RELEASE FAN BOX AND
LIFT IT CLEAR OF BODY
8
DISCONNECT POWER CORD WIRES (TAKE NOTE OF
COLOUR POSITIONS) FROM TERMINAL BLOCK, DISPOSE OF
OLD POWER CORD
9
ASSEMBLE NEW POWER CORD AND REASSEMBLE UNIT IN
REVERSE OF ABOVE PROCEDURE
10
TEST TO APPROPRIATE ELECTRICAL STANDARD BEFORE
USE
TO CHANGE LAMP
1
DISCONNECT FROM POWER SUPPLY
2
REMOVE FILTER
3
REMOVE GLASS DISFUSSER BY UNDOING AND REMOVING
RETAINER. SLIDE DIFFUSER IN TOWARD CENTRE OF UNIT
TO CLEAR
4
CHANGE LAMP (NOTE 40W MAX)
5
REPLACE DIFFUSER AND FILTER IN REVERSE OF ABOVE
PROCEDURE