3.3 Rigging the fixture

The overhead installation must always be secured with a secondary safety attachment, e.g. an appropriate 

safety rope. This secondary safety attachment must be constructed in a way that no part of the installation can 

fall down if the main attachment fails.

When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges, 

under high working places and other endangered areas is forbidden.

The operator has to make sure that safety-relating and machine-technical installations are approved by an 

expert before taking into operation for the first time and after changes before taking into operation another time.

The operator has to make sure that safety-relating and machine-technical installations are approved by an 

expert after every four year in the course of an acceptance test.

The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled 

person once a year.

The fixture should be installed outside areas where persons may walk by or be seated.

IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to) 

calculating working load limits, installation material being used, and periodic safety inspection of all installation 

material and the projector. If you lack these qualifications, do not attempt the installation yourself, but instead 

use a professional structural rigger. Improper installation can result in bodily injury or damage to property.

The fixture has to be installed out of the reach of people.

If the fixture shall be lowered from the ceiling or high joists, professional trussing systems have to be used. The 

fixture must never be fixed swinging freely in the room.

Caution: 

Fixture  may cause severe injuries when crashing down! If you have doubts concerning the safety of 

a possible installation, do not install the moving head!

Before rigging make sure that the installation area can hold a minimum point load of 10 times the fixture’s weight.

 

When installing the device, make sure there is no highly inflammable

 

material (decoration articles, etc.) in a distance of min. 1 m.

CAUTION!

 

 

Use an appropriate clamp to rig the fixture on the truss.   

 

 

 

 

 Follow the instructions mentioned at the bottom of the base. 

 

 

Make sure that the device is fixed properly! Ensure that the 

structure (truss) to which you are attaching the fixtures is secure.

The  fixture can be placed directly on the stage floor by means of the removable stand (4) or rigged HORIZON

-

TALLY ONLY on a truss by means of the omega holder (1) and clamp (2) . Both removable stand and omega 

holder can be fastened with two 1/4-turn locks to the bottom of the fixture. Adjust fixture´s head to desired 

position and tighten tilt lock (5) to secure the head position.

For securing the fixture to the truss install a safety wire that can hold at least 10 times the weight of the fixture. 

.

Содержание actor 12

Страница 1: ...1 Version 1 0...

Страница 2: ...rt 18 6 Control menu 23 6 1 Addressing DMXA 23 6 2 Zoom Zoom 23 6 3 Virtual colour wheel Vir C 23 6 4 Dimmer Dimm 23 6 5 Fixture information Info 23 6 6 Personality Pers 24 6 7 Manual Control Manual 2...

Страница 3: ...he fuses or any part The power plug has to be accessible after installing the fixture Do not overload wall outlets and extension cords as this canresult in fire or electric shock Do not allow anything...

Страница 4: ...igging derigging or servicing the fixture Do not block the front objective LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture to c...

Страница 5: ...5 2 Fixture exterior view 5 Apertures for safety chain 6 DMX out 7 DMX in 8 PowerCon socket 9 Fuse holder 10 Apertures for quick turn fasteners 1 Moving head 2 Tilt lock 3 Control buttons 4 Display...

Страница 6: ...ply that automatically adjusts to any 50 60Hz AC power source from 100 240 Volts If you need to install a suitable plug on the power cord note that the cores in the power cord are coloured according t...

Страница 7: ...g screws 3 which securing flange 4 to the head 5 and install new flange Keep its right position the cutouts A in the flange must look towards the arms Original flange New flange 2 Place the top hat 1...

Страница 8: ...ange and transparent plastic cover 3 from the head 2 Unscrew the three fastening screws 4 which securing black eggcrate 5 to the zoom module 6 and remove it 3 Put the transparent eggcrate on the zoom...

Страница 9: ...ot attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury or damage to property The fixture has to be installed out of the...

Страница 10: ...read the snap hook through two apertures in the fixture base and the wire around the truss as shown on the picture below 1 Safety wire 2 Apertures for safety wire 3 Trust When installing fixtures side...

Страница 11: ...re in the DMX chain If you wish to connect DMX controllers with other XLR out puts you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX cha...

Страница 12: ...High Res Sw Ver IC 1 IC 2 IC 3 Pers DMX Pres Mode 1 Mode 6 DMX In Wired Wireless Display Turn On Off T On Off Contrast 0 100 Backlight 0 100 C Cal M On Off C Mix M RGBW CMY Mic Sens 0 10 19 Fans Auto...

Страница 13: ...2 Prog 3 Pr Edit Prog 1 Step 1 Pan Prog 2 Prog 3 Step 40 F Tim 0 25 5 S Tim 0 25 5 COPY Prg End 1 40 Reset Special RDM Low RDM Hight Wireless Stat Unlink Adjust DMX Val Pover 0 255 Dimm F 0 255 Calib...

Страница 14: ...e of fans fans noise from min to max step step step step step step step step proportional 2 2 0 255 Red Cyan 8 bit all zones Red or cyan LEDs saturation control 0 100 proportional 3 0 255 Red Cyan fin...

Страница 15: ...1 19 0 255 Blue Yellow 8 bit zone 2 Blue or yellow LEDs saturation control 0 100 proportional 15 22 20 0 255 Blue Yellow fine 16 bit zone 2 Fine blue or yellow LEDs saturation control proportional 16...

Страница 16: ...9 10 12 13 15 16 17 55 56 57 95 96 97 134 135 136 174 175 176 214 215 216 246 247 248 249 250 251 252 253 254 255 Virtual Colour Wheel For detailed description see Virtual colour wheel colour mixing c...

Страница 17: ...low fast All zones together Closing pulses in sequences from fast slow All zones together Random strobe effect from slow fast random zone Random strobe effect from slow fast random zone random strobe...

Страница 18: ...22 0 18 255 0 23 0 21 255 0 24 0 24 255 0 25 0 27 255 0 26 0 30 255 0 27 0 36 255 0 28 0 41 255 0 29 0 46 255 0 30 0 52 255 0 31 0 58 255 0 32 0 64 255 0 33 0 68 255 0 34 0 74 255 0 35 0 80 255 0 36...

Страница 19: ...4 0 81 0 255 58 0 82 0 255 52 0 83 0 255 46 0 84 0 255 41 0 82 0 255 36 0 86 0 255 30 0 87 0 255 27 0 88 0 255 24 0 89 0 255 21 0 90 0 255 18 0 91 0 255 15 0 92 0 255 12 0 93 0 255 9 0 94 0 255 6 0 95...

Страница 20: ...255 246 0 0 137 255 237 0 0 138 255 228 0 0 139 255 219 0 0 140 255 210 0 0 141 255 201 0 0 142 255 192 0 0 143 255 183 0 0 144 255 174 0 0 145 255 165 0 0 146 255 156 0 0 147 255 147 0 0 148 255 138...

Страница 21: ...0 68 0 193 255 0 74 0 194 255 0 80 0 195 255 0 86 0 196 255 0 92 0 197 255 0 98 0 198 255 0 104 0 199 255 0 110 0 200 255 0 119 0 201 255 0 129 0 202 255 0 138 0 203 255 0 147 0 204 255 0 156 0 205 25...

Страница 22: ...0 255 0 231 110 0 255 0 232 104 0 255 0 233 98 0 255 0 234 91 0 255 0 235 84 0 255 0 236 77 0 255 0 237 70 0 255 0 238 63 0 255 0 239 56 0 255 0 240 49 0 255 0 241 42 0 255 0 242 35 0 255 0 243 28 0 2...

Страница 23: ...d independently from any other fixture on the DMX data link If there is no data received at the DMX input the display will start to flash 0001 with actually stored DMX address 6 2 Zoom Zoom The motori...

Страница 24: ...e display permanent on or turn it off two minutes after last pressing any button on the control panel Contrast Use this function to adjust contrast of the display 0 100 Backlight Use this function to...

Страница 25: ...n the current step and a fade time during which effects move to new positions To edit program Procedure 1 Press NEXT or PREV to select the menu Edit and press ENTER 2 Press NEXT or PREV to select the...

Страница 26: ...dows 95 98 2000 XP 7 or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 if you want to use a serial port of PC Robe Universal Interface if you want to use an USB port of PC Note 1 Softwa...

Страница 27: ...cific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands for Robin Actor 12 ST is the following Parameter ID Discovery command...

Страница 28: ...is displayed in the menu item Wireless Special Wireless Stat To unlink the fixture from DMX transmitter The fixture can be unlinked from receiver via the menu item Unlink Special Wireless Unlink 9 Er...

Страница 29: ...tc Built in analyzer for easy fault finding error messages Built in demo sequences Silent fans cooling Stand alone operation 3 user editable programs each up to 40 steps Supported protocols USITT DMX...

Страница 30: ...dirt and smoke fluid residues must not build up on or within the fixture Otherwise the fixture s light output will be significantly reduced Regular cleaning will not only ensure the maximum light out...

Страница 31: ...ver from the housing anti clockwise 2 Remove the old fuse from the fuse holder 3 Install the new fuse in the fuse holder only the same type and rating 4 Replace the fuse holder in the housing and fix...

Страница 32: ...32 13 Photometric diagrams...

Страница 33: ...33...

Страница 34: ...34...

Отзывы: