![Robin America RGV2800 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/robin-america/rgv2800/rgv2800_service-manual_1470209057.webp)
- 54 -
(3) Check the insulation resistance between sta-
tor core and each stator lead using a Dr. Robin
generator tester in megger tester mode or a
megger tester. (Fig. 11-3)
If insulation is bad, replace stator with a new
one.
11-1-3 CHECKING ROTOR
(1) Remove rear cover and stator.
(2) Using a Dr. Robin or a circuit tester, measure
the resistance of the field coil at the terminals.
NOTE : Because a diode is soldered to the coil
ends at the terminals, resistance may be mea-
sured only when tester probes touch the termi-
nals in one combination of polarity. Therefore, if
no resistance reading appears, try checking in
reverse polarity.
[Remedy]
If the resistance is not normal, replace rotor with
a new one.