(3) DIODE RECTIFIER
The internal circuit of the diode rectifier is shown in the figure below.
Check the continuity between each terminal using a circuit tester.
If the continuity is as charted below, the diode rectifier is normal.
Diode rectifier
Circuit Tester
Yellow
Yellow / Blue
Gray
Orange
Yellow
Yellow / Blue
Orange
Gray
Apply black (-) needle of the circuit tester
0
Ω
−
Yellow
Checking table for analogue circuit tester
Analogue Circuit Tester
0
Ω
No continuity
∞
Yellow / Blue
Apply red (+) needle
of the circuit tester
0
Ω
0
Ω
Orange
−
No continuity
∞
No continuity
∞
−
0
Ω
No continuity
∞
No continuity
∞
No continuity
∞
−
No continuity
∞
Gray
Yellow
Yellow / Blue
Orange
Gray
Apply red (+)needle of the circuit tester
0
Ω
−
Yellow
Checking table for digital circuit tester
Digital Circuit Tester
0
Ω
No continuity
∞
Yellow / Blue
Apply black (-) needle
of the circuit tester
0
Ω
0
Ω
Orange
−
No continuity
∞
No continuity
∞
−
0
Ω
No continuity
∞
No continuity
∞
No continuity
∞
−
No continuity
∞
Gray