background image

Page x of y 
Rev 02 05/04/05 

 
 

 

Memory Recall 
“UP” or “DOWN”  

LAP Counter 

CHRONO Indicator 

SPLIT Indicator 

¾

 

Chrono in Split Time 
mode 

¾

 

Chrono stopped in 
RESET position 

¾

 

Memory Recall in 
ascending order “UP” 

 
 
The appropriate indicator “LAP”, “SPL” or “LAP/SPL” will appear. 
 

MEMORY RECALL DIRECTION 

Select between ascending (up) or descending (dn) memory recall by pressing “D” while Chrono is in the 
RESET (all zeros) position.  The recall direction can only be selected while the Chrono is in the reset (all 
zeros) position.  You cannot select between “UP” or “DN” while the time is running, or not reset. 
 

30 MEMORY RECALL Operation 

 
You may access up to the previous 30 readings while the Chronograph is running or stopped by pressing 
“F”.  The recall operation will ascend or descend, depending upon the option selected. 
 
Simply press “F” at any time to review previous readings.  Recall (“RCL”) indicator appears.  Holding “F” 
down, will scroll through the memory recall function. 
 
If “RUN” indicator appears, you may take a reading by pressing “B” or stop the chrono by pressing “A” at 
any time while using the memory.  You may also return to the last previous reading at any time, by 
pressing “C”. 
 

AVERAGE LAP TIME, MAXIMUM (FASTEST) LAP TIME: 

The Average and Fastest Lap Times can be displayed at any time by pressing “D”.  “AVG” indicator will 
appear for Average Lap Time, and “MAX” indicator will appear for the Fastest Lap Time. 
 

LAP CHRONOGRAPH Operation 

 
In the Chrono mode, Press “C” until “LAP” indicator appears. 
 
Single Events:  Press “A” once to start.  Press “A” again to stop.  Press “B” to reset to all zeros. 
 
Timing Multiple Laps:  Press “A” to start.  “RUN” indicator appears,  Lap Time appears running in the 
lower row.  Press “B” to take a Lap Time.  The previous Lap Time will appear in the upper row of the 
display and the current Lap Time will build up from zero in the bottom row.   The SC-554 will take up to 
999 lap times. The LAP COUNTER will  increase by one (1) each time “B” is pressed to take a Lap Time. 
 
Press “A” to stop, “STOP” indicator appears.  LAP COUNTER will increase by one (1) when timer is 
stopped.  Press “B” once to display total accumulated time of the event.  Then press “B” again to reset to all 
zeros. 
 
For MEMORY RECALL and AVG/MAX operations, please proceed as described above. 
 

SPLIT CHRONOGRAPH Operation 

 
In the Chrono Mode, press “C” until Split “SPL” indicator appears. 
 

Содержание SC-554

Страница 1: ...s activated by pressing a pushbutton Once you are familiar with the SC 554 s operation you will be ready to enjoy its many functions The starting point for any operation is the NORMAL TIME mode You ma...

Страница 2: ...up to Previous 30 Laps in Ascending up or Descending down Order Automatic Lap Counter up to 999 Laps Enter Distance Precise to 1 1000 Mile or Kilometer 1 100 Second Resolution up to 24 Hours Automatic...

Страница 3: ...s C to arm or disarm your alarm and chime The sequence is 1 Alarm ON Chime OFF 2 Chime ON Alarm OFF 3 Alarm ON Chime ON 4 Alarm OFF Chime OFF When armed the alarm will sound when the Alarm Time coinci...

Страница 4: ...le using the memory You may also return to the last previous reading at any time by pressing C AVERAGE LAP TIME MAXIMUM FASTEST LAP TIME The Average and Fastest Lap Times can be displayed at any time...

Страница 5: ...frozen in the upper and lower rows of the display You may press E to release the frozen display to the current running LAP and SPLIT times or the SC 554 will automatically do so after 15 seconds Upon...

Страница 6: ...t are Water Ski Slalom Course 850 feet 0 161 mile Pitcher s Mound Baseball 60 5 feet 0 011 mile Pitcher s Mound Youth 47 feet 0 009 mile Pitcher s Mound Softball 45 47 feet 009 mile Convert meters to...

Страница 7: ...r is in the reset position The recall direction cannot be selected while the Speed Timer is running or not in the reset position 1 For Single Lap Events Press A to start RUN indicator appears Press A...

Страница 8: ...perate unless a distance has been entered 2 The SC 554 will measure up to 24 hours or 999 laps LIMITED WARRANTY OUR BASIC POLICY Marshall Browning International Corporation MBI Corp warrants to the or...

Страница 9: ...er resistant avoid immersing or exposing it to water steam or other forms of moisture WHEN YOU REQUIRE SERVICE If your timepiece ever requires factory servicing you can send it directly to MBI Corp 11...

Отзывы: