15. Replace thermostat cover by snapping into place.

16. Turn on power to system. Test thermostat as described in the 

following section.

Step 3: Testing the Thermostat

WARNING:

DO NOT SHORT (JUMPER) ACROSS TERMINALS 
OF GAS VALVE OR SYSTEM CONTROL TO TEST
OPERATION. THIS WILL DAMAGE THE 
THERMOSTAT AND VOID YOUR WARRANTY.

CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE 

IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR 
CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY.

1. Place the EMER-HEAT-OFF-COOL switch into 

the COOL position. The display will read COOL.

2. Press the 

button until the temperature setting 

is at least 3 degrees below the room temperature. 

The air conditioning system should turn on within 

a few seconds. The snowflake icon 

will be displayed

(

1

st

stage cooling; 

2

nd

stage cooling).

6

TERMINAL LEGEND - 9420

TERM

EQUIPMENT TO CONNECT

REQ?

TERMINAL FUNCTION

C

24VAC common connection

Yes

For input of 24VAC common
side of transformer

L

System fault indicator connection

No

For connection of system
fault indicator (if present)

R

24VAC hot connection

Yes

For input of 24VAC hot side
of transformer

Y2

Second stage cooling connection

No

Energizes on a call for 
second stage cooling

Y1

First stage compressor connection

Yes

Energizes on a call for 
first stage of heating and
cooling

E

Emergency heat connection

No*

Energizes on a call for heat
in the EM mode only

G

Indoor fan connection

Yes

Energizes with E, Y1, Y2 and
W2 terminals or with FAN
option switched to the ON
position

W2

Second stage heat connection

No*

Energizes on a call for 
second stage of heat 
(auxiliary heat)

O

Cool active reversing 

Yes**

Energizes when in the in 

valve connection

COOL mode

B

Heat active reversing 

Yes**

Energizes when in the 

valve connection

HEAT or EM modes

*

For systems using a backup heat source. If separate E terminal connection is not available,
jumper E and W2.

** Most heat pump systems will have a cool active or a heat active reversing valve. Use the

appropriate terminal.

!

Содержание 9420

Страница 1: ...djustable 1st stage temperature differential 0 5 F to 3 0 F 0 5 C to 1 5 C Adjustable 2nd stage temperature differential 1 F to 6 F 0 5 C to 3 0 C Adjustable 2nd stage delay 10 40 min Compressor short cycle protection Accuracy within 1 Zone system compatible as a master thermostat Permanent memory retention Fahrenheit Celsius display option Adjustable from 45 F to 90 F 7 C 32 C Quick wire terminal...

Страница 2: ...placing Existing Thermostat 1 Turn off power to heating and cooling system 2 Remove cover from old thermostat to expose wires Figure 1 3 Disconnect wires one at a time from existing terminals Use enclosed labels to mark existing wires Refer to cross references in Table 1 if existing wiring does not directly match the labels 4 Remove existing thermostat base from wall Old Terminal New Label Descrip...

Страница 3: ...completing the change the display will return to the current room temperature after a few seconds CHANGING THE TEMPERATURE DIFFERENTIAL DEAD BAND AND RESIDUAL COOL The temperature differentials are factory set at 1 F and 2 F for 1ST and 2ND stages respectively The dead band for Auto changeover is set at 3 F To change settings 1 Press the and buttons at the same time and hold for 1 second Display w...

Страница 4: ...a 3 16 drill bit 9 Align base with plastic anchors and feed wires through opening 10 Secure base to wall with supplied screws NOTE THE THERMOSTAT WILL MOUNT HORIZONTALLY ON A SINGLE GANG JUNCTION BOX 11 Strip end of wires 5 16 if needed 12 Terminal screws are already loose and ready for wire insertion Insert wires into terminal strip Figure 5 matching the label to the corresponding terminal see Wi...

Страница 5: ...iary emergency heat Does not have separate wire for emergency heat jump W2 E Typical heat pump with cool active reversing valve auxiliary emergency heat and second stage of cooling System fault indicator connected L terminal O B 9420 WIRING SAMPLE 1 Y1 E G W2 C L R Y2 9420 WIRING SAMPLE 2 C L R Y2 Y1 E G W2 O B 9420 WIRING SAMPLE 3 B Y1 E G W2 C L O E G R Y2 Jumper O B 9420 WIRING SAMPLE 4 C W2 L ...

Страница 6: ...nection Yes For input of 24VAC common side of transformer L System fault indicator connection No For connection of system fault indicator if present R 24VAC hot connection Yes For input of 24VAC hot side of transformer Y2 Second stage cooling connection No Energizes on a call for second stage cooling Y1 First stage compressor connection Yes Energizes on a call for first stage of heating and coolin...

Страница 7: ... read HEAT 5 Press the button until the temperature setting is at least 3 degrees above room temperature The heating system should turn on The fan may not turn on immediately depending on the fan delay built into the furnace The flame icon will be displayed 1st stage heating 2nd stage heating 6 Put the EMER HEAT OFF COOL switch into the OFF position The heating system should turn off The fan may c...

Страница 8: ...t temperature for heating is 70 F 21 C To change the default setpoint put the system switch in HEAT and press the or button to adjust the temperature setting up or down The display will show SET The display will return to the current room temperature three seconds after the last input and the new setpoint will be saved Cooling The default temperature for cooling is 78 F 25 C To change the default ...

Страница 9: ...emperature in degrees Fahrenheit US models or degrees Celsius Canadian models The temperature display can be changed Press and hold both the and button for three seconds The display will read F or C Release buttons Press the or button to switch the display 2 After three seconds the display will switch to the 1st stage differential settings The display will read DIFFERENTIAL 1st The temperature dif...

Страница 10: ...ider Check F C Fahrenheit Celsius setting See Changing Fahrenheit F to Celsius C Thermostat does not display proper room temperature Thermostat turns system on and off too frequently Thermostat does not turn on system Check wiring see Installation section Increase temperature differential see Changing the Temperature Differential section If problems with thermostat cannot be resolved call Technica...

Страница 11: ...acement as provided under this warranty is the exclusive remedy of the consumer Climate Controls Americas shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product or under any other theory of liability Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose on ...

Страница 12: ...NOTES 12 ...

Отзывы: