WIRING ROBERTSHAW VSI TO ROBERTSHAW 5500 M SERIES
Connect wires from old switch to new switch as follows:
VSI Switch
5500M (MPA) Switch
Terminal #
Terminal #
L1
connect to
L1
L2
connect to
L2
P
connect to
P
H1
connect to
H1
H2
connect to
HC
WIRING EGO TO ROBERTSHAW
Old (EGO) Switch
5500 M (MPA) Switch
Terminal #
Terminal #
P1
connect to
L2
P2
connect to
L1
Pilot
Pilot
connect to
P
4
4
connect to
H1
2
2
connect to
HC
(L2)
(P)
(L1)
(H1)
(HC)
(L2)
(P)
(L1)
(H1)
(HC)
0.75
0.75
1.10
MAX DISTANCE
0.614
1.50
0.886
0.886
1.77
(4X) 8-32 MOUNTING NUTS
WIRING SCHEMATIC
WARNING: The rear housing has a ¼”
diameter hole which is an access point to
be used ONLY by qualified personnel for
insuring proper assembly and calibra-
tion of the switch. Any tampering with
internal components or altering factory
settings of this switch will possibly dam-
age other electrical components on the
appliance and will immediately VOID the
WARRANTY of the switch.
MOUNTING DIMENSIONS
5500M Series
Replaces
UNI-LINE PART #
FACTORY #
UNI-LINE PART #
FACTORY #
VOLTAGE
MODEL
5500-103M
MPA-V112-1-UXM
5500-103
INF-120-599
120V AC
RESIDENTIAL
5500-104M
MPA-V112-1-UXM
5500-104
INF-120-599
120V AC
RESIDENTIAL
5500-113M
MPA-V113-1-UXM
5500-113
INF-120-599B
120V AC
RESIDENTIAL
5500-203M
MPA-V116-UXM
5500-203
INF-240-597
240V AC
RESIDENTIAL
5500-204M
MPA-V116-UXM
5500-204
INF-240-597
240V AC
RESIDENTIAL
5500-208M
MPA-V115-2-UXM
5500-208
INF-208-642
208V AC
RESIDENTIAL
5500-213M
MPA-V117-UXM
5500-213
INF-240-597B
240V AC
RESIDENTIAL
5500-134M
MPA-V114-1-UNM
5500-134
INF-120-1152
120V AC
COMMERCIAL
5500-135M
MPA-V114-1-UNM
5500-135
INF-120-1152
120V AC
COMMERCIAL
5500-234M
MPA-V119-UNM
5500-234
INF-240-1153
240V AC
COMMERCIAL
5500-235M
MPA-V119-UNM
5500-235
INF-240-1153
240V AC
COMMERCIAL
ORDERING INFORMATION
SLIP-FIT® DIAL ASSEMBLY
NOTE: IT IS ESSENTIAL TO READ EACH STEP COMPLETELY BEFORE
PERFORMING THE DIRECTIONS GIVEN IN THAT STEP.
1. Turn control to the “Off” position.
2. Locate the 4-way insert included with this dial kit.
Push the 4-way insert flush onto the tip of the dial shaft of the control.
3. Referring to the other control knobs on the appliance, determine
which way the new knob is to be oriented in the “Off” position; vertical
or horizontal.
4. Using the vertical or horizontal orientation desired, partially
assemble the knob onto the insert to obtain proper alignment.
Then remove the knob with the insert attached, and press the insert all
the way onto the knob. When completely in place, approximately 1/8” of
the 4-way insert will be outside of the knob. Reinstall knob.
5. Take the Slip-Fit overlay, and carefully remove the clear protective
covering over the numbered side. Begin removal from the inside edge
of the overlay.
6. Carefully peel off the backing from the adhesive that is on the back
of the Slip-Fit overlay. Try not to touch the adhesive.
7. Position the Slip-Fit dial overlay over the knob with the “Off”
position aligned in the desired position. Carefully slide the
Slip-Fit overlay down and over, locating the ribs on the knob.
8. Press the Slip-Fit overlay firmly into position. Use a soft cloth and
rub around the overlay to obtain a permanent fit.
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
Robertshaw®, Ranco®, Paragon® and Uni-Line® are trademarks of
Robertshaw, its subsidiaries and/or affiliated companies. All other
brands mentioned may be the trademarks of their respective owners.
For Technical Service
Telephone 1.800.445.8299
www.robertshaw.com
©2016 Robertshaw
07/16 –354-00028-003 RevB