background image

SECTION 8: T

HE

 ROBERTS GORDON

®

 VANTAGE

®

 NP W

ARRANTY

  

21

SECTION 8: THE ROBERTS GORDON

®

 VANTAGE

®

 NP WARRANTY

ROBERTS-GORDON WILL PAY FOR:

ROBERTS GORDON

®

 warrants to the original owner-user 

that this ROBERTS GORDON

®

 product will be free from 

defects in material and workmanship. This warranty is 
limited to thirty-six (36) months from the date of purchase 
by the original consumer, or forty-two (42) months from 
date of shipment by Roberts-Gordon, whichever occurs 
first.

ROBERTS GORDON

®

 replacement parts are warranted 

for the period of the original ROBERTS GORDON

®

 

VANTAGE

®

 NP Warranty.

ROBERTS-GORDON WILL NOT PAY FOR:

Service trips, service calls and labor charges.
Shipment of replacement parts.
Damage due to:

Failure to install, operate or maintain the ROBERTS 

GORDON

®

 VANTAGE

®

 NP as directed in Installation, 

Operation and Service Manual. You must follow 
requirements printed in this manual.

Misuse, abuse, neglect or modification of the 

ROBERTS GORDON

®

 VANTAGE

®

 NP in any way.

Improper service, use of replacement parts or 

accessories that are not specified by Roberts-Gordon.

Improper installation, or any relocation of the 

ROBERTS GORDON

®

 VANTAGE

®

 NP after initial 

installation.

Incorrect supply, accident, fire, flood, acts of God or 
other casualty.

Use of the ROBERTS GORDON

®

 VANTAGE

®

 NP for 

other than its intended purpose.

Use of the ROBERTS GORDON

®

 VANTAGE

®

 NP in a 

corrosive atmosphere or any atmosphere containing 
contaminants.

Shipping. Claim must be filed with carrier.

Use of the ROBERTS GORDON

®

 VANTAGE

®

 NP in 

the vicinity of combustible or explosive materials.

Any defect in the ROBERTS GORDON

®

 VANTAGE

®

 

NP arising from a drawing, design or specification 
supplied by or on behalf of the consumer.

Failure of parts not manufactured by Roberts-Gordon 

in respect of any claim where the total price of the 
goods has not been paid.

WARRANTY IS VOID IF:

The ROBERTS GORDON

®

 VANTAGE

®

 NP is not installed 

by a contractor qualified in the installation and service of 
gas-fired heating equipment.

You cannot prove original purchase date and required 
annual maintenance history.

The data plate and/or serial number are removed, 
defaced, modified or altered in any way.

The ROBERTS GORDON

®

 VANTAGE

®

 NP is transferred. 

This warranty is nontransferable.

Roberts-Gordon is not permitted to inspect the damaged 
burner and/or component parts.

READ YOUR INSTALLATION, OPERATION AND 
SERVICE MANUAL

If you have questions about your heater, contact your 
installing professional. Should you need Replacement 
Parts or have additional questions, call or write Roberts-
Gordon:

U.S.A.

1250 William Street
P.O. Box 44
Buffalo, New York 14240-0044
716.852.4400

On the web at: 

www.rg-inc.com

Roberts-Gordon's liability, and your exclusive remedy, 
under this warranty or any implied warranty (including 
the implied warranties of merchantability and fitness 
for a particular purpose) is limited to providing 
replacement parts during the term of this warranty. 

Some jurisdictions do not allow limitations on how long an 
implied warranty lasts, so this limitation may not apply to 
you. There are no rights, warranties or conditions, 
expressed or implied, statutory or otherwise, other than 
those contained in this warranty.

Roberts-Gordon shall in no event be responsible for 
incidental or consequential damages or incur liability 
for damages in excess of the amount paid by you for 
the ROBERTS GORDON

®

 VANTAGE

®

 NP.

 Some 

jurisdictions do not allow the exclusion or limitation of 
incidental or consequential damages, so this limitation or 
exclusion may not apply to you. This warranty gives you 
specific legal rights, and you may also have other rights 
which vary from jurisdiction to jurisdiction.

Roberts-Gordon shall not be responsible for failure to 
perform under the terms of this warranty if caused by 
circumstances out of its control, including but not limited to 
fire, flood, strike, government or court orders, unavailability 
of supplies, parts or power. No person is authorized to 
assume for Roberts-Gordon any other warranty, obligation 
or liability.

LIMITATIONS ON AUTHORITY OF 
REPRESENTATIVES:

No representative of Roberts-Gordon, other than an 
Executive Officer, has authority to change or extend these 
provisions. Changes or extensions shall be binding only if 
confirmed in writing by Roberts-Gordon's duly authorized 
Executive Officer.

Содержание Vantage NP CTHN040NP

Страница 1: ...one 716 852 4400 Fax 716 852 0854 Toll Free 800 828 7450 www rg inc com Copyright 2006 Roberts Gordon LLC Quality in Any Language CTHN 40 CTHN 60 CTHN 80 CTHN 100 CTHN 125 CTHN 150 CTHN 175 CTHN 200 P N 252101NA Orig 10 06 Vantage NP Fuel Conversion Kit Instructions WARNING FOR YOUR SAFETY If you smell gas 1 Open windows 2 DO NOT try to light any appliance 3 DO NOT use electrical switches 4 DO NOT...

Страница 2: ......

Страница 3: ...atural to Propane 3 SECTION 4 For Propane to Natural Conversions Only 4 4 1 Contents of Fuel Conversion Kits Propane to Natural 4 SECTION 5 Fuel Conversion Instructions 5 5 1 Burner Removal 5 5 2 Door Assembly Removal 5 5 3 Burner Cup Assembly Removal and Reassembly 7 5 4 Regulator Spring Replacement 7 5 5 Inlet Gas Pressure Checks 8 5 6 Adjust Regulator 8 5 7 Burner Conversion Label Information 1...

Страница 4: ......

Страница 5: ... 7 Figure 7 Burner Side View internal assembly 8 Figure 8 Manometer Reading Gas Pressure 9 Figure 9 Manometer Reading Differential Reading 10 Figure 10 Label P N 91039400 11 Figure 11 Standard Reflector 13 Figure 12 One Side Reflector 13 Figure 13 Two Side Reflectors 13 Figure 14 45 Tilt Reflector 14 Figure 15 U Tube Standard Reflector 14 Figure 16 U Tube 45 14 Figure 17 U Tube Opposite 45 Reflect...

Страница 6: ......

Страница 7: ...cal codes and ordinances and applicable standards that apply to gas piping electrical wiring venting etc must be thoroughly understood before proceeding with the installation Thin sheet metal parts such as the reflector portion of the heater and the various venting components have sharp edges To prevent injury the use of work gloves is recommended The use of gloves will also prevent the transfer o...

Страница 8: ...del number and installed configuration are found on the burner and in the Installation Operation and Service Manual See Page 13 Figure 11 through Page 14 Figure 16 Write the proper clearance dimensions in permanent ink according to your model number and configuration in the open spaces on the tag 2 2 Corrosive Chemicals Roberts Gordon cannot be responsible for ensuring that all appropriate safety ...

Страница 9: ...______ fuel Orifice Manifold Pressure Input Cet appareil a été converti au Injecteur Pression à la tubulure d alimentation Débit calorifique Printed in the U S A Imprimé aux Etats Unis P N 91039400 Sping Kit P N 90032600 Gas Conversion Label P N 91039400 Orifice P N See Table Below Cap Screw black O Ring black Pressure Regulator Adjusting Screw white Spring red Pressure Regulator Housing Kit Numbe...

Страница 10: ...fuel Orifice Manifold Pressure Input Cet appareil a été converti au Injecteur Pression à la tubulure d alimentation Débit calorifique Printed in the U S A Imprimé aux Etats Unis P N 91039400 Sping Kit P N 90032700 Gas Conversion Label P N 91039400 Orifice P N See Table Below Cap Screw silver O Ring black Pressure Regulator Adjusting Screw white Spring silver Pressure Regulator Housing Kit Number M...

Страница 11: ...gas supply valve disconnect gas from burner 2 Turn off power supply and disconnect wires from burner 3 Unplug thermostat wires from burner 4 If outside air is installed disconnect 5 Remove the bolts which hold the burner on the transition tube using a 1 2 wrench 6 Remove the burner See Figure 3 7 Save the gasket P N 02568200 or re install a new one after conversion Step 5 2 Door Assembly Removal R...

Страница 12: ... Burner Top View internal assembly Install Label Here P N 91039400 Control Side Door 2 Thumb Screws Vantage NP by ROBERTS GORDON Air Side Door 3 Thumb Screws Motor and Blower Assembly Blower Inlet Gasket Air Adapter Collar Burner Cup Hot Surface Igniter Door Switch Gas Valve Orifice Manifold ...

Страница 13: ...external tooth washer is in place then tighten the burner cup 7 Replace the air side door 8 Replace the electrode Step 5 4 Regulator Spring Replacement See Figure 6 1 Replace the regulator spring Using a flat head screwdriver remove the cap from the regulator adjusting screw remove the screw and remove and replace the spring 2 NOTE Silver spring for Natural red spring for Propane 3 See Page 3 Sect...

Страница 14: ... the heater must be adjusted as necessary 9 Turn off main gas supply to heater 10 Turn off electrical supply to heater 11 Remove manometer and insert pipe plug into valve 12 Turn on main gas supply to heater 13 Leak test plug in tapping using soap solution 14 Turn on electrical supply to heater Step 5 6 Adjust Regulator 1 Using a 3 16 hex key remove the plug at the valve outlet and install a test ...

Страница 15: ... wc 6 5 4 3 2 1 0 1 2 3 4 5 6 Top View of Heater Manometer Valve Inlet Valve Outlet Regulator WARNING Electrical Shock Hazard Disconnect electrical power and gas supply before servicing This appliance must be connected to a properly grounded electrical source Failure to follow these instructions can result in death or electrical shock ...

Страница 16: ...ometer Remove Cap Attach Manometer Hose Remove Cap Attach Manometer Hose 75 wc WARNING Electrical Shock Hazard Disconnect electrical power and gas supply before servicing This appliance must be connected to a properly grounded electrical source Failure to follow these instructions can result in death or electrical shock ...

Страница 17: ...ith thumbscrews Enter Data for Natural to Propane Conversions Enter Data for Propane to Natural Conversions Model Propane Orifice Size Model Natural Orifice Size CTHN 40 1 8 mm CTHN 40 33 CTHN 60 44 CTHN 60 29 CTHN 80 2 6 mm CTHN 80 21 CTHN 100 33 CTHN 100 16 CTHN 125 1 8 CTHN 125 9 CTHN 150 3 4 mm CTHN 150 3 CTHN 175 27 CTHN 175 A CTHN 200 23 CTHN 200 E This appliance has been converted to ______...

Страница 18: ...d below the heater Maintain clearances from swinging and overhead doors overhead cranes vehicle lifts partitions storage racks hoists etc In locations used for the storage of combustible materials signs must be posted to specify the maximum permissible stacking height to maintain required clearances from the heater to the combustibles Signs must be posted adjacent to the heater thermostat In the a...

Страница 19: ...20 112 188 112 CTHN 200 8 47 76 47 20 119 193 119 FIGURE 12 ONE SIDE REFLECTOR inches centimeters Model A B C D A B C D CTHN 40 5 6 46 35 13 15 117 88 CTHN 60 5 6 55 44 13 15 140 110 CTHN 80 5 6 64 49 13 15 163 123 CTHN 100 5 6 66 51 13 15 168 128 CTHN 125 5 6 69 58 13 15 175 145 CTHN 150 5 6 75 60 13 15 191 150 CTHN 175 8 6 77 68 20 15 196 170 CTHN 200 8 6 79 70 20 15 201 175 A C D B FIGURE 13 TW...

Страница 20: ...10 4 69 68 25 10 175 173 CTHN 200 10 4 73 71 25 10 185 180 FIGURE 15 U TUBE STANDARD REFLECTOR inches centimeters Model A B C D A B C D CTHN 40 UNAPPROVED UNAPPROVED CTHN 60 5 27 56 19 13 69 142 48 CTHN 80 5 30 61 20 13 76 155 51 CTHN 100 5 32 63 20 13 81 160 51 CTHN 125 5 35 66 20 13 89 168 51 CTHN 150 5 39 73 21 13 99 185 53 CTHN 175 8 44 75 26 20 112 191 66 CTHN 200 8 47 76 30 20 119 193 76 FIG...

Страница 21: ...25 173 175 51 CTHN 200 10 71 73 20 25 180 185 51 A C D B FIGURE 18 2 FOOT DECO GRILLE 1 FOOT DECO GRILLE AND PROTECTIVE GRILLE inches centimeters Model A B C D A B C D CTHN 40 5 20 41 20 13 51 104 51 CTHN 60 5 27 51 27 13 69 130 69 CTHN 80 5 30 58 30 13 76 147 76 CTHN 100 5 32 60 32 13 81 152 81 CTHN 125 5 35 65 35 13 89 165 89 CTHN 150 5 39 71 39 13 99 180 99 CTHN 175 8 44 74 44 20 112 188 112 CT...

Страница 22: ...of tubing downstream from where the burner and burner tube connect FIGURE 20 VENTING inches centimeters Model A E F A E F CTHN 40 14 18 18 36 46 46 CTHN 60 14 18 18 36 46 46 CTHN 80 20 24 18 51 61 46 CTHN 100 20 24 18 51 61 46 CTHN 125 20 24 18 51 61 46 CTHN 150 20 30 18 51 76 46 CTHN 175 20 30 18 51 76 46 CTHN 200 20 30 18 51 76 46 Radiant Tubes Vent Pipes Unvented Vented A E F ...

Страница 23: ...ving power from the module for at least 5 seconds thermostat cycle required 7 2 To Shut Off Heater Set thermostat to lowest setting Turn OFF electric power to heater Turn OFF manual gas valve in the heater supply line 7 3 To Start Heater Turn gas valve and electric power OFF and wait five minutes for unburned gases to vent from heater Turn ON main gas valve Turn ON electric power Set thermostat to...

Страница 24: ...age The Vicinity of the Heater Do not store or use flammable objects liquids or vapors near the heater Immediately remove these items if they are present See Page 12 Section 6 Vehicles and Other Objects Maintain the clearances to combustibles Do not hang anything from or place anything on the heater Make sure nothing is lodged underneath the reflector in between the tubes or in the decorative or p...

Страница 25: ...ider webs will cause problems Carefully remove any dust and debris from the burner Direct Spark Igniter Sense Rod Replace if there are cracked ceramics excessive carbon residue or erosion of the Direct Spark Igniter Sense Rod Thermostat There should be no exposed wire or damage to the thermostat Suspension Points Make sure the heater is hanging securely Look for signs of wear on the chain or ceili...

Страница 26: ...e inlet and outlet of the pump for blockage or excessive soot and clean as necessary Check boots for cracking or deterioration and replace if necessary If a condensate trap is installed check the condition of the trap and the drain line attatched Note the condensate trap should be filled with water at the beginning of each heating season Check the condition of the motor mounts Lift the motor from ...

Страница 27: ...ce history The data plate and or serial number are removed defaced modified or altered in any way The ROBERTS GORDON VANTAGE NP is transferred This warranty is nontransferable Roberts Gordon is not permitted to inspect the damaged burner and or component parts READ YOUR INSTALLATION OPERATION AND SERVICE MANUAL If you have questions about your heater contact your installing professional Should you...

Страница 28: ......

Страница 29: ...n the installation and service of products sold and supplied by Roberts Gordon and conform to all requirements set forth in the ROBERTS GORDON manuals and all applicable governmental authorities pertaining to the installation service and operation of the equipment To help facilitate optimum performance and safety Roberts Gordon recommends that a qualified contractor annually inspect your ROBERTS G...

Страница 30: ......

Страница 31: ......

Страница 32: ...Service Telephone 44 0 1902 498733 Service Fax 44 0 1902 401464 E mail uksales rg inc com E mail export rg inc com Roberts Gordon LLC 1250 William Street P O Box 44 Buffalo NY 14240 0044 USA Telephone 716 852 4400 Fax 716 852 0854 Toll Free 800 828 7450 WARNING Roberts Gordon Europe Limited Oxford Street Bilston West Midlands WV14 7EG UK Telephone 44 0 1902 494425 Fax 44 0 1902 403200 Installation...

Отзывы: