EP-100 P
UMP
I
NSTALLATION
, O
PERATION
AND
S
ERVICE
M
ANUAL
14 of 29
7.2 Wall Mountin
g
7.2.1 Wall Mountin
g
Platform
The alternati
v
e method of mo
u
nting the p
u
mp is on
an o
u
tside
w
all and
v
enting directly thro
u
gh the
w
all.
Order the optional mo
u
nting angle package
(P/N 01312102) if this method is
u
sed.
The p
u
mp may be mo
u
nted by
u
sing mo
u
nting
angles as sho
w
n
on Page 14, Figure 11
and Page
15, Figure 12
. The t
w
o mo
u
nting angles form a
mo
u
nting platform to
w
hich the p
u
mp
w
ill be
attached.
Fix mo
u
nting frame to
w
all
u
sing anchors. Select an
anchor that
w
ill gi
v
e
u
ltimate p
u
ll-o
u
t strength eq
u
al
to or greater than 2000 lbs.
FIGURE 11: Wall Bracket Assembly
Mounting
Angle
Hex Head Bolt
Flat Washer
Lockwasher
Hex Nut
Flat Washer
Description
Part Number
Mo
u
nting Angle Package
01312102
Mo
u
nting Angle
01365000
Hex Bolt 5/16" x 3/4"
93413912
Flat Washer
95211600
Lock
w
asher
96411600
Hex N
u
t
92113900