background image

Model

75

100

125

150

175

200

225

250

300

350

400

Total Input 

[Btu/h] x [1000]

75

100

125

150

175

200

225

250

300

350

385

Total Output 

[Btu/h] x [1000]

61.5

82

102.5

123

143.5

164

184.5

205

246

288.6

315.7

Efficiency

 82% - All Models

Number of Burners

5

6

7

7

8

9

10

11

12

14

14

Gas Connection 

[in]

½

½

½

½

½

½

¾

¾

¾

¾

¾

Inlet Pressure  

[in wc] NG Min. 5

 

LPG Propane Min. 12

 

NG & LPG Propane Max. 14

Electrical Supply

115 V / 60 Hz / 1 Ø - All Models

Minimum Air Volume 

[CFM]

850

950

1020

1360

1400

2050

2100

2350

2700

3120

3420

Temperature Rise @  

Minimum Air Volume 

[°F]

68

78

92

83

95

73

80

80

86

86

86

Heat Exchanger Pressure Drop 

@ Minimum Air Volume 

[in wc]

0.06

0.05

0.06

0.02

0.03

0.025

0.035

0.05

0.02

0.03

0.04

Maximum Air Volume 

[CFM]

2650

3660

4750

5800

6850

7750

8300

8850

10200

13600

14200

Temperature Rise @  

Maximum Air Volume 

[°F]

22

22

20

20

20

20

20

22

23

22

22

Heat Exchanger Pressure Drop 

@ Maximum Air Volume 

[in wc]

0.36

0.55

0.98

0.16

0.29

0.163

0.253

0.35

0.27

0.48

0.53

Flue Size 

[in] 4 - All Models

Air Intake 

[in]

4

4

4

4

4

4

4

4

5

5

5

Weight 

[lb]

81

92

97

191

211

239

249

254

325

345

345

Printed in U.S.A.

UHDSNA

5M 0308  Orig.

Installation Code and Annual Inspections: 

 

All installations and service of ROBERTS GORDON

®

 equipment must be performed by a contractor qualified in the installation and  

service of equipment sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON

®

  

manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate 

optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON

®

 

equipment and perform service where necessary, using only replacement parts sold and supplied by Roberts-Gordon. 

Further Information:

 Applications, engineering and detailed guidance on systems design, installation and equipment performance is avail-

able through ROBERTS GORDON

®

 representatives. Please contact us for any further information you may require, including the Installation, 

Operation and Service Manual. 

This product is not for residential use.

This document is intended to assist licensed professionals in the exercise of their professional judgement. 

© 2008 Roberts-Gordon LLC   All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or    

 

 

   

by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage  

 

 

 

and retrieval systems – without written permission of Roberts-Gordon LLC.

 

Combat

®

 UHD[S]-Series Technical Data

Roberts-Gordon LLC

1250 William Street

P.O. Box 44

Buffalo, NY 14240-0044 USA 

Telephone: 716.852.4400

Fax: 716.852.0854

Toll Free: 800.828.7450

www.rg-inc.com

European Office:

Roberts Gordon Europe Limited

Telephone: +44(0) 121 506 7700

Fax: +44(0) 121 506 7701

Содержание Combat UHD[S] 150-400

Страница 1: ... 75 125 only Helps reduce dirt build up on burners and helps extend life of heat exchanger with separated combustion units Longer life and less maintenance with optional stainless steel heat exchangers Install downstream of refrigeration system with option stainless steel heat exchangers and drain pan Models UHD S 150 400 only Combat UHD S Series TubularDuctFurnaces 1 800 828 7450 www rg inc com t...

Страница 2: ...in 17 75 23 23 B Duct Connectors in 1 25 1 25 1 25 C Center of Flue Top Option in 5 2 6 9 6 9 D Center of Flue in 2 5 2 5 2 5 Combat UHD S 75 UHD S 125 ClearancesandDimensionData B 20 25 1 8 A D Flue 28 5 1 5 3 3 4 x 3 8 Captive Nuts Provided 16 63 B 17 63 Rear View Top View Gas Supply 6 75 Air Intake UHDS only Side View C Air Intake UHDS only Optional Position Flue Optional Position 18 25 Electri...

Страница 3: ...r Intake Center in 6 6 6 6 6 7 7 7 H Position of Flue in 4 5 4 5 4 75 4 75 4 75 4 9 4 9 4 9 J Gas Inlet Position in 5 9 5 9 5 9 5 9 5 9 8 7 8 7 8 7 K Electrical Supply Position in 3 4 3 4 3 4 3 4 3 4 6 2 6 2 6 2 K B C 25 5 A J 2 4 6 5 4 x 3 8 Captive Nuts Provided C F D 19 4 Support Centers Rear View End View G H Top View Heater must be supported at these points from above or below Electrical Supp...

Страница 4: ...Gordon and conform to all requirements set forth in the ROBERTS GORDON manuals and all applicable governmental authorities pertaining to the installation service and operation of the equipment To help facilitate optimum performance and safety Roberts Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON equipment and perform service where necessary using only replaceme...

Отзывы: