background image

www.robertjuliat.com

115W LED SINGLE LENS LUMINAIRE

DN41202100 (EN)

M

anual

Robert Juliat S.A.S.  32, rue de Beaumont,  F 60530 Fresnoy-en-Thelle  -  phone : +33 (0)3 44 26 51 89 - fax : +33 (0)3 44 26 90 79 - [email protected]

Version V1 

LED SINGLE LENS LUMINAIRE

VALIDATION : 09/06/21

Type

Standard

North American

Fresnel

305LF

305CLF

Pebble Convex

305LPB

305CLPB

Содержание SULLY 305CLF

Страница 1: ...l Robert Juliat S A S 32 rue de Beaumont F 60530 Fresnoy en Thelle phone 33 0 3 44 26 51 89 fax 33 0 3 44 26 90 79 info robertjuliat fr Version V1 LED SINGLE LENS LUMINAIRE VALIDATION 09 06 21 Type St...

Страница 2: ...ge 12 4 3 2 Control 12 4 4 Beam size adjustment 13 4 4 1 Range 13 4 4 2 Control 13 4 5 Orientation 13 4 5 1 Range 13 4 5 2 Control 14 4 6 Colour 14 4 7 Beam shaping 15 4 7 1 Range 15 4 7 2 Control 15...

Страница 3: ...en electrical mains cable connections regularly and replace with one of identical specification if damaged 16 Use only with correct power supply VENTILATION 17 Keep well away from flammable material 1...

Страница 4: ...connector 5 Handle 6 Safety cable attachment point 7 Hanging yoke 8 Tilt index 9 Tilt locking handle 10 Focus adjustment 11 Lens Fresnel or Pebble 12 Accessories and colour filter holders 13 Accessori...

Страница 5: ...ht kilogram kg Intensity Ampere A Voltage Volt V Frequency Hertz Hz Temperature degree Celsius C 1 MOD Model 2 VERS Version 3 U Nominal voltage input V 4 I Nominal intensity A 5 P Maximum power input...

Страница 6: ...PAPF00016 PF500M2 180 x 180 mm metal filter holder 4 FPACF00002 CF500 4 rotating leaves on a rotating barndoor 180x180mm without safety cable weight 0 82 Kg 5 FPACAH0007 TH600 180x180mm Top hat withou...

Страница 7: ...een a flammable material and the lighting unit 3 1 3 Instructions for use 3 1 4 Hanging Ensure fixture is correctly mounted on an appropriate support Minimum 40 C 104 F 5 C 40 F IP20 Indoor use only M...

Страница 8: ...connected directly to AC power Do not connect to dimmer power Automatic mains voltage detection Power Maximum 22 units 230V 16A 12 units 120V 15A 10 units 100V 15A When hung or flown the fixture must...

Страница 9: ...PE UL CSA 1 5 m 4 9 ft Live Black Neutral White Ground Green DATA connectors PIN DMX Description 1 Shielding Foil Braided Shield 2 DMX 1st conductor of 1st twisted pair 3 DMX 2nd conductor of 1st twis...

Страница 10: ...sary if the unit is connected to a network switch to control multiple devices The usage of non IGMP switch capability can cause erratic behavior of all connected devices For further reading https en w...

Страница 11: ...EN EN 9 3 4 2 Barndoors 3 4 3 Changing lens 1 2 3 1 2 4 5 3 L150 F 2 Filter frame slot Front accessories safety cable attachment point Barndoors slot L150 PB 2...

Страница 12: ...web interface 4 1 3 2 Dimming curve T Set through RDM protocol or web interface Resolution DMX mode 8 bits 255 steps 1 3 16 bits 65 535 steps 2 4 Remotely with DMX512 A Art Net sACN protocols Locally...

Страница 13: ...otocol or web interface 4 1 3 4 Dimming mode T Set through RDM protocol or web interface 100 100 0 0 Maximum 80 Light Output Mode Result Without PWM Flicker Free perfect for filming PWM 17 kHz Good di...

Страница 14: ...ms 255 20ms 255 10Hz T Remotely with DMX512 A Art Net sACN protocols Mode 3 4 4 3 2 Control Remotely with DMX512 A Art Net sACN protocols Mode 3 4 Locally with DMX 512 A Art Net sACN protocols Mode 1...

Страница 15: ...4 Beam size adjustment 4 4 1 Range 4 4 2 Control 4 5 Orientation 4 5 1 Range Beam angle 18 Field angle 29 Beam angle 67 Field angle 100 Minimum Maximum Minimum Maximum Beam angle 8 Field angle 16 Beam...

Страница 16: ...EN EN 14 4 6 Colour Location Front filter holder Type Standard coloured gel filter Dimensions Installation See 3 4 1 4 5 2 Control Fixed colour Index...

Страница 17: ...EN EN 15 4 7 Beam shaping 4 7 1 Range 4 7 2 Control...

Страница 18: ...an ethernet cable T If IP address unknown due to a previous modification a hard reset must be done see 6 5 Factory defaults By defaut DHCP OFF Address 2 XXX XXX XXX Mask 255 0 0 0 The computer must b...

Страница 19: ...5 2 1 Trouble shooting 1 2 3 1 DMX OUT 2 DMX IN 3 Network Display auto off DMX protocol detected without data received No ethernet Ethernet detected link Ethernet detected data DMX protocol detected w...

Страница 20: ...5 3 1 Protocol E1 11 2008 USITT DMX512 A 5 3 2 Configuration 5 3 3 Parameters 5 3 3 1 DMX Hold If data not detected Hold last values Default value Standalone value Reset DMX values T Set through RDM p...

Страница 21: ...trol mode 5 3 5 DMX ranges 5 3 5 1 Strobe duration Range min Range max Function 0 0 Strobe OFF 1 255 Strobe ON 1 ms T 20 ms Range min Range max Function 0 0 OFF 1 255 Dimmer timing 0 1 s T 4 s Range m...

Страница 22: ...IL_ID_LIST X X 00 80 DEVICE_MODEL_DESCRIPTION X X 00 81 MANUFACTURER_LABEL X X 00 82 DEVICE_LABEL X X X X 00 90 FACTORY_DEFAULTS X X X X 00 C0 SOFTWARE_VERSION_LABEL X X X 00 C2 BOOT_SOFTWARE_VERSION_...

Страница 23: ...T_RESULT X X 85 59 CURRENT_IP_ADDRESS X X X 85 5A CURRENT_NETMASK X X X 85 5B CURRENT_DRIVER_STATUS X X X 85 5C CUSTOM_RESPONSE_TIME_DESCRIPTION X X 85 5D CUSTOM_RESPONSE_TIME_VALUE X X X X 85 60 DATA...

Страница 24: ...5 1 Web interface 1 If necessary change IP settings 2 Set Art Net Universe 3 Set DMX address 2 Set personality mode see 5 3 4 DMX chart 5 6 sACN remote control 5 6 1 Protocol ANSI E1 31 2009 sACN Stre...

Страница 25: ...fo Software version LED board IDs Device hours Description of the problem Lens access 6 Service 6 1 Preventive maintenance 6 1 1 Frequency General maintenance should be performed at least once a year...

Страница 26: ...Upload your firmware file upd2 in the Update firmware section and then click on Submit firmware 6 5 Factory defaults 6 5 1 Modes 6 5 2 Control T If IP address unknown due to a previous modification I...

Отзывы: