EN
- 7 -
3.1.5
Safety cable
When hung or flown the fixture must be
secured by an additional hanging
accessory (such as a safety bond or
cable) of suitable length.
The combined weight of both the fixture
and the accessories must be considered
when choosing the load-bearing capability
of safety cable or bond.
Safety cables or bonds must be securely
attached to the back of the fixture and be
as short as possible, or rolled up as
necessary, to minimise travel distance
should the fixture be dislodged.
3.2
Electrical
3.2.1
LED source
Never touch or scratch LED surface.
See
5.1.4 LED cleaning procedure
if cleaning is necessary.
3.2.2
Power
Power supply
Voltage
Frequency
Input power
Connectors
90
264 V
50/60 Hz
0.5 amps @ 230V
0.9 amps @ 120V
1.4 amps @ 90V
105 W (Max.120 W)
Standby mode: 15 W
Neutric PowerCon®
Input: ref. NAC3MPA
Output: ref.NAC3MPB
Class 1 product.
This luminaire must be earthed.
Must be connected directly to AC power.
Do not connect to dimmer power
Automatic power detection
On the same breaker, maximum of: 14 units (230V) / 12 units (110V)
Daisy chain:
Maximum of:
14 units (230V)
12 units (110V)
Содержание ALEDIN 330CLF CW
Страница 10: ...EN 9 3 3 Accessories 3 3 1 Gel frame...
Страница 14: ...EN 13 4 3 2 Control Manual 4 3 3 Control Pole operated Colour Function Yellow Focus...
Страница 16: ...EN 15 4 5 Colour One fixed colour Any standard colour effect filter gel See 3 3 1 for installation Size...
Страница 17: ...EN 16 4 6 Beam shaping with barndoors option 4 6 1 Range 4 6 2 Control Examples Open Triangle Square Line...
Страница 23: ...EN 22...