Robern SS476 MP Скачать руководство пользователя страница 3

Product  

Width  Number 

Unit 

Unit

Model 

 

of Units  Width 

Height

CABINET MP16 

15 1/4” 

 

 

XXXXXXXX

CABINET MP20 

19 1/4” 

 

 

XXXXXXXX 

CABINET MP24 

23 1/4” 

 

 

XXXXXXXX

LIGHT MP-L1.5 

1 1/2” 

 

 

XXXXXXXX

TOTAL WIDTH  OVERALL 

XXXXXXXX 

 

XXXXXXXX

ROUGH 

 

OPENING  XXXXXXXX 

-3/4” 

XXXXXXXX

TOTAL ROUGH  OPENING  XXXXXXXX 

 

XXXXXXXX

TOTAL HEIGHT

 

OVERALL

  FLAT TOP  XXXXXXXX 

39 3/8”

 

 

 

ARCH 

XXXXXXXX 

43 3/8

TOTAL HEIGHT 

R.O. 

ALL SHAPES  XXXXXXXX 

38 5/8”

Product  

Width  Number 

Unit 

Unit

Model 

 

of Units  Width 

Height

CABINET MP16 

15 1/4” 

30 1/2” 

XXXXXXXX

CABINET MP20 

19 1/4” 

19 1/4” 

XXXXXXXX 

CABINET MP24 

23 1/4” 

 

 

XXXXXXXX

LIGHT MP-L1.5 

1 1/2” 

 

XXXXXXXX

TOTAL WIDTH  OVERALL 

XXXXXXXX 

52 3/4” 

XXXXXXXX

ROUGH 

 

OPENING  XXXXXXXX 

-3/4” 

XXXXXXXX

TOTAL ROUGH  OPENING  XXXXXXXX 

52” 

XXXXXXXX

TOTAL HEIGHT

 

OVERALL

  FLAT TOP  XXXXXXXX 

39 3/8”

 

 

 

ARCH 

XXXXXXXX 

43 3/8

TOTAL HEIGHT 

R.O. 

ALL SHAPES  XXXXXXXX 

38 5/8”

Single units

Multiple Units

2.  With the doors off, combine the boxes 

  with the proper connectors to assemble 

  the units per your layout. Use the #10 x 

  1/2” thread cut screws. 

  Assemble on a convenient flat surface, 

  not on or in wall. 

  Do not attach lights, doors or side kits until 

  boxes are secured to wall. 

  Note location of holes in the cabinets which 

  are used to secure connectors and side kits 

  in figure E. 

CABINET

MP CONNECTORS

#10 X 1/2"

SCREWS

CABINET

CABINET

FIG. D

 

CABINET TO CABINET

OR CABINET TO

SIDE KIT CONNECTIONS

USING MP65

MP65L

MP60

CONNECTORS

USE #10 X 1/2"

THREAD CUT CONNECTOR

BLOCK SCREWS AND CAP 

USE ONLY FOR

RECESSED CABINETS

USE #10 PAN HEAD 

S.MS/WOOD SCREW

( 2" OR 3") AND CAP

MOUNTING BAR

FOR SURFACE

MOUNT

  6 1/2"  

CENTERLINE

OF

ELECTRICAL

CONNECTION

FOR MP CABINET

CENTERLINE

OF

ELECTRICAL

CONNECTION

FOR MP LIGHT

MP LIGHT

MP CABINET

OPTIONAL

ELECTRIC

OUTLET SHELF

"E" OPTION

 

MOUNT /

UNMOUNT

HINGE

HERE

DOOR 

HINGE

MP CABINET

TOP "Z" CLIP FOR

SURFACE MOUNT

3 PER CABINET
USE ONLY FOR

RECESSED CABINETS

USE #10 PAN HEAD 

S.MS/WOOD SCREW

( 2" OR 3") AND CAP

( LOCATION OF WALL

WHEN CABINET IS

SURFACE MOUNTED )

CABINET TO CABINET

OR CABINET TO

SIDE KIT CONNECTIONS
USE #10 X 1/2"

THREAD CUT CONNECTOR

BLOCK SCREWS AND CAP

ACCESS SCREWS

FOR OUTLET SHELF

( LOCATION OF WALL

WHEN CABINET IS

RECESSED )

1 2

3

BOTTOM OF CABINET

HINGE

TOP OF

CABINET

19 3/4"

Fig. D

Fig. E

Содержание SS476 MP

Страница 1: ...t Refer to model number designations below to determine if cabinet was ordered 2 Glass Shelves 4 Shelves are provided with each cabinet 3 Shelves are provided with each E option cabinet 3 Z Mounting Brackets Bracket used for surface mounted cabinets 4 Hardware Bag Contains the Following A 12 Clear Snap In Shelf Clips B 46 Shelf Hole Plugs C 6 SMS WOOD Screws 10 X 2 D 5 SMS Wood Screws 10 X 3 E 8 C...

Страница 2: ...TOTAL WIDTH OVERALL XXXXXXXX 52 3 4 XXXXXXXX ROUGH OPENING XXXXXXXX 3 4 XXXXXXXX TOTAL ROUGH OPENING XXXXXXXX 52 XXXXXXXX TOTAL HEIGHT OVERALL FLAT TOP XXXXXXXX 39 3 8 ARCH XXXXXXXX 43 3 8 TOTAL HEIGHT R O ALL SHAPES XXXXXXXX 38 5 8 MP L1 5 MP16D4FBN MP20D4ABRE MP16D4FBN MP L1 5 Single units Multiple Units 1 Each cabinet light and side kit contains special connectors to allow all combinations of c...

Страница 3: ...K SCREWS AND CAP USE ONLY FOR RECESSED CABINETS USE 10 PAN HEAD S MS WOOD SCREW 2 OR 3 AND CAP MOUNTING BAR FOR SURFACE MOUNT 6 1 2 CENTERLINE OF ELECTRICAL CONNECTION FOR MP CABINET CENTERLINE OF ELECTRICAL CONNECTION FOR MP LIGHT MP LIGHT MP CABINET OPTIONAL ELECTRIC OUTLET SHELF E OPTION MOUNT UNMOUNT HINGE HERE DOOR HINGE MP CABINET TOP Z CLIP FOR SURFACE MOUNT 3 PER CABINET USE ONLY FOR RECES...

Страница 4: ...he circuit Includes two convenient outlets plus a 75 watt door heater The door included with this option is equipped with a disconnect cord The door swings left or right MP lights Use a 120 VAC 15 amp circuit up to 4 lights per circuit The MP 1 5 light fixtures use either a 150 watt tubular incandescent bulb MPIL1 5 sold under the trade names Philinea by Philips and Linestra by Osram or 25 watt T ...

Страница 5: ...other a remote The master contains the transformer 7 Fasten fixture at the MP65L connector between the cabinets or MP60 connector at the ends of the cabinet 4 Recessed Cabinet and Light Installation see page 6 for surface inst 16 16 2 MP1640FBN CABINETS 1 MP2040ABRE CABINET 1 MP L1 5 LIGHT KIT 2 PER KIT 36 8 36 3 4 26 26 847 20 A 110VAC CABINET CIRCUIT GFI BREAKER REQUIRED 15 A 110VAC LIGHT CIRCUI...

Страница 6: ...ontinued on page 7 LOCATE BRACKET TO CLEAR SINK FAUCETS BY AT LEAST ONE INCH MOUNTING BRACKET 10 X 2 SMS WOOD SCREW 1 X 3 FURRING STRIP BEHIND WALLBOARD OR TILE LOCATED AT CENTER OF BOTTOM EDGE OF CABINET Fig L Recessed Cabinet and Light Installation Continued 8 Install doors following the instructions supplied with the hinge and shown in Figure E on page 3 9 Adjust doors so that there is a gap of...

Страница 7: ...stall sequence as shown in figure M 6 The MTSK30 side kit is used to finish the sides of the surface mount installation 6a Attach keyhole bracket to cross bracket using 10 x 1 2 screws Be sure that the keyhole is up as shown on page 8 6b Attach l bracket to cabinet side using 10 X 1 2 screws into cross bracket 6c Attach light fixture 6d Screw two 10 x 1 2 screws into each bracket on SK mirror Leav...

Страница 8: ... a damp cloth to clean Mirrors are damaged by the use of ammonia or vinegar based cleaning agents Use rubbing alcohol for stubborn marks B Use no abrasive cleansers on any part of the cabinet Limited Warranty One Year Term ROBERN warrants to the original purchaser that it will at its election repair replace or make appropriate adjustment to products made by this company shown to have significant d...

Отзывы: