Accessories
- Omega holder (No.99010420)................................2 pcs
.
.
Optional Accessories
- Flash cable RS232/DMX (No.13050624)
- Module of Front wide-angle lens D200 (No.99010879)
- Top hat standard 45 (No.10980044)
- Top hat long 70 (No.10980045)
- Top hat 3-ring 45 (No.10980046)
- Top hat 3-ring 70 (No.10980050)
11. Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build
up on or within the fixture. Otherwise, the fixture‘s light-output will be significantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
DANGER !
Disconnect from the mains before starting any
maintenance work
The front fresnel lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light-output very quickly. The cooling-fans should be cleaned monthly.
The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
Dichroic colour filters, CMY lamellas and the internal zoom lamellas should be cleaned monthly.
Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum-cleaner.
Important! Check the air filters periodically and clean before they become
clogged!
Clean the air filters placed in the fixture´s covers. Use a vacuum cleaner, compressed air or you can wash
them and put back dry.
After replacing the air filters, reset the elapsed time counter in the menu "Information" (Information--->Air Fil
-
ters---> Elapsed Time).