23
was > 0% (e.g. if dimmer = 50% for one hour, the adaptive time is 0.5 hour, if dimmer = 100%
for one hour, the adaptive time is 1 hour).
Actual Module Info
- Use the item to read current information about the LEDs module installed in
the fixture.
Serial Number/ Device UID
- a serial number of the LEDs module/RDM UID of the fixture.
Measurement Date/Time
- a date/time of running the procedure "LEDs Measure" in the tab
Service.
Intensity
- the item shows a light intensity of the LEDs module measured after running
the procedure "LEDs Measure" in the tab Service. The light intensity is displayed in percentages
in relation to the initial intensity of the new LEDs module (initial intensity=100%).
LEDs On Time Total/Adaptive
- Total: a total time of the LEDs module operation during which
the dimmer intensity was > 0%.
Adaptive: a relative time of the LEDs module operation during which the dimmer intensity
was > 0% (e.g. if dimmer = 50% for one hour, the adaptive time is 0.5 hour, if dimmer = 100%
for one hour, the adaptive time is 1 hour).
Assembly History
- Use the item to read a history of the LEDs module installed in the fixture (its serial
number, RDM UID of fixture at which was installed and date/time of installation).
Up to 31 records can be saved in the menu item.
I
ntensity History
- Use the item to read a history of light intensity of the LEDs module installed in the fixture.
Serial Number/ Device UID
- a serial number of the LEDs module/RDM UID of the fixture.
Measurement Date/Time
- a date/time of running the procedure "LEDs Measure" in the tab
Service.
Intensity
- the item shows a light intensity of the LEDs module measured after running
the procedure "LEDs Measure" in the tab Service. The light intensity is displayed in percentages
in relation to the initial intensity of the new LEDs module (initial intensity=100%) .
Up to 31 records can be saved in the menu item.
LED Modules History
- Use the item to read a history of the LEDs modules installed in the fixture (their serial
numbers and date/time of installation).
Up to 31 records can be saved in the menu item.
View Logs
- Use this menu to read fixture´s data which have been recorded during fixture operation. This
collected data allows easier troubleshooting.
Fixture Errors
- Use this menu to read fixture errors which have occurred during fixture operation.
Fixture States
- In the menu are recorded fixture states as power on and power off.
Fixture Positions
- In the menu are recorded installation positions of the fixture:
Fixture Temperatures
- In the menu are recorded temperatures which have exceeded defined levels.
Note: The log buffer can contain max. 8000 records. If the buffer is full, old data will be overwritten.
Display
Display
Bottom
Top
Side Bottom
Side Top
Front Inverted
Front Normal