![Robe CitySkape 48 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/robe/cityskape-48/cityskape-48_user-manual_1468863017.webp)
CitySkape 48 (RGBW)
17
LoAd
---
Load of LEDs
. The menu allows to choose 2 different operating modes for fixture´s LEDs.
FuLL
--- Maximum light output.
EcO.
--- The light output is decreased by 25%.
In.Po.
---
Init effect positions.
Use this function to set all effects to the desired positions to which they will move
after switching the fixture on (if DMX is not being received).
Note. If DMX mode 1 is selected, only values set at items “MACr” (macro) and dinr (dimmer) will be accepted.
rAd.t.
---
Unlink time.
Use this menu to set time after that the linked fixture will be unliked from the transmitter, if
the transmitter does not transmit DMX signal.
OFF
--- Fixture is permanently linked.
1-255.
--- Time from 1-255 minutes.
dF.SE.
---
Default Settings .
The menu item sets all fixture parameters to the default (factory) values.
6.4 Manual mode
Use this menu for control the fixture without connected DMX console.
PrE.C.
--- Preset effects control. Select this menu to call up preset positions of the channel effects.
Man.C.
--- Manual effect control. Select this menu to control all channels via buttons of the control board.
To control fixture channels.
1.
Use the UP/DOWN buttons to find “ Man.C“ menu.
2.
Press the ENTER button.
3.
Use the UP/DOWN buttons to select desired effect (channel).
List of control channels:
“
rEd1” -
red LEDs saturations
“GrE1“ - green LEDs saturations
“bLu1“ - blue LEDs saturations
“Whi1“ - white LEDs saturations
“MACr“ - colour macros
“Stro.“ - a strobe, shutter
“dimr“ - a dimmer
“F.dim” a fine dimmer
4.
Press the ENTER button and use the UP/DOWN buttons to set value , press the ENTER button to confirm it.
6. 5 Test sequences
Use this menu to run demo-test sequences without an external controller, which will show you some possibilities
of using the CitySkape 48.
6.6 Stand-alone setting
The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be
different for every fixture. “Stand-alone operation” can be applied to the single fixture or to multiple fixtures
operating synchronously.