Version 1.8
Страница 1: ...Version 1 8 ...
Страница 2: ...terior view 4 3 Installation 5 3 1 Mounting the fixture 5 3 2 Connection to mains 5 3 3 The Booster box 7 3 4 The Booster box installation 9 3 5 Jumper cable assembling 11 4 Technical specifications 14 5 Cleaning and maintenance 17 5 1 Disposing of the product 17 6 ChangeLog 17 ...
Страница 3: ...icing or installing Make sure the data power cable is not damaged by sharp edges Check the fixture and the power cord from time to time Do not install the unit near an open flame During operation the housing becomes hot Refer servicing to qualified service personnel This fixture falls under protection class I Therefore this fixture has to be connected to a mains socket outlet with a protective ear...
Страница 4: ...field higher than 3V m The installation company should check levels of possible interferences above the tested levels E1 E2 E3 given by this standard e g transmitters in surrounding area before installing the equipment Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment Emission Requirements according to class B Please consider that un...
Страница 5: ... and construction codes and regulations This device falls under class one and must be grounded The Eminere is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 120 277 Volts The following wiring of the input output connectors applies to the fixtures marked X on their labels only Older versions of the Emineres have swapped D and D and do not ha...
Страница 6: ...running the unlink procedure at DMX transmitter or by switching off on the Eminere three times while the transmitter is switched off During off on unlink procedure the Eminere has to be switched on for 5 seconds in steps 1 3 Step 1 Eminere Off Eminere On 5seconds Step 2 Eminere Off Eminere On 5seconds Step 3 Eminere Off Eminere On 5seconds Step 4 Eminere Off Eminere On Successful unlink is signali...
Страница 7: ... 32 32 70 m 6 16 23 32 100 m 4 11 16 23 Cable length is a total cable length among connected Emineres Side including power cable of the first Eminere Side Example Total cable length L1 L2 L3 3 3 The Booster box To compensate a voltage drop in a large installation the Booster boxes have to be connected in the chain of Emineres The following tables give numbers of Emineres after which the Booster bo...
Страница 8: ...m 6 12 18 24 30 15 30 21 31 EMINERE 4 Wireless DMX Max possible number of Emineres 4 Wireless DMX 32 Voltage Cable length 120V 190V 230V 277V 10 m 21 20 m 21 30 m 15 30 50 m 9 18 27 22 70 m 6 12 18 24 30 16 23 100 m 4 8 12 16 20 24 28 11 22 16 23 Example E box Daisy Power supply 120V Cable length 70m fixture Eminere 2 wireless DMX The Booster box has to be connected after every 12th Eminere 2 wire...
Страница 9: ...ew the Booster box on a non flammable flat surface and connect cables The Cable gland M20x1 5 for Power IN 5 is intended for a cable of a diameter of 7 13mm Remove the end cap from the cable gland before passing the cable Power connection L N earth Core EU Braun Blue Green yellow Core US Black White Green We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of th...
Страница 10: ...le of diameter of 6 12mm for smaller diameter of cable 4 8mm you have to remove the original seal from the cable gland M20 and use the enclosed reducing seal instead of it The reducing seal for diameter of cable 4 8mm P N 13051388 is enclosed in the Booster box 3 Screw the cover 2 back on the Booster box ...
Страница 11: ... P N 13053139 The seal with inner diameter of 14 5 mm serves for cable of diameter 10 14 5mm The seal with inner diameter of 10 mm serves for cable of diameter 8 10mm Parts of the connector 2 Put the seiling circle 2 on the connector with screws 1 3 Remove insulation from the cable 6 and from individual wires and fasten three terminals on data wires CE version Detail of Sealing circle 2 placing ...
Страница 12: ...on 4 Put parts of the connector on the cable 6 and connect wires to the connector First connect power wires L N Earth and after that data wires D D 0V Avoid excessive torsion of data wires CE version Male Female US version Male Female ...
Страница 13: ... 6 Screw the clamp ring 3 to the connector 1 insert the seal 4 to the clamp ring 3 and tighten the sealing nut 5 enough During the steps DO NOT TWIST the cable 6 7 Use the same procedure to assemble the connector on the second end of the cable IMPORTANT Do not bend the cable near to the connector minimum distance for bending is 50mm ...
Страница 14: ...ngle Symetrical 9 15 30 50 65 100 Bi symetrical 10 x 30 30 x 10 10 x 60 60 x 10 35 x 70 70 x 35 15 x 90 90 x 15 Wallwasher Wide Wallwasher Projected LED Life 60 000 Hrs L70 25 C77F Mounting method Via two L shape brackets LED module tilt adjustment range 95 95 Sizes Eminere 2 600mm 2ft Eminere 3 900mm 3ft Eminere 4 1200mm 4ft Housing Aluminium extruded body with die casted end caps Tempered glass ...
Страница 15: ... C Ambient 40 C 153 F Ambient 104 F Connection Input panel connector Amphenol ABAB DMQ06000021 IN P N13052952 Output panel connector Amphenol ABAB DAQ06000021 P N13052953 water tight cap Weight Eminere 2 4 kg 8 82 lbs Eminere 3 6 02 kg 13 27 lbs Eminere 4 7 7 kg 17 lbs Dimensions All dimensions in mm inch ...
Страница 16: ...53052 Jumper Cable FF FM 0 5m P N 13053053 Jumper Cable FF FM 1m P N 13053054 Jumper Cable FF FM 2m P N 13053055 Jumper Cable FF FM 3m P N 13053056 Jumper Cable FF FM 5m P N 13053057 Jumper Cable FF FM 10m P N 13053058 Waterproof Cover Cap FM ZAHB 0006 P N 17031173 Field Installable Connector FF P N 13053003 Field Installable Connector FM P N 13053004 ...
Страница 17: ...e and a mild non abrasive washing detergent Rinse it Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use ROBE OEM parts 5 1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes 6 ChangeLog This section summarizes chang...