9
In order to reset some counter to 0 you have to press and hold the UP and DOWN
buttons and at the same time press the ENTER button.
"dM In" ---DMX input values
. Select this function to read DMX values of each channel received by the fixture.
"tEMP" ---LED module temperature
. Select this menu to read temperature of a connected LED module:
"Cur.t."
--- the current temperature of the LED module.
"LEd1."
- temperature in the ArcSource Submersible II connected to the LED output 1.
"LEd2."
- temperature in the ArcSource Submersible II connected to the LED output 2.
"LEd3."
- temperature in the ArcSource Submersible II connected to the LED output 3.
"LEd4."
- temperature in the ArcSource Submersible II connected to the LED output 4.
"Hi.tE."
--- the maximum temperature of the ArcSource Submersible II since the ArcSource Submersible
II has been fabricated.
"LEd1."
- temperature in the ArcSource Submersible II connected to the LED output 1.
"LEd2."
- temperature in the ArcSource Submersible II connected to the LED output 2.
"LEd3."
- temperature in the ArcSource Submersible II connected to the LED output 3.
"LEd4."
- temperature in the ArcSource Submersible II connected to the LED output 4.
"rSEt"
--- the maximum temperature of the LED module since the counter was last reset.
"LEd1."
- temperature in the ArcSource Submersible II connected to the LED output 1.
"LEd2."
- temperature in the ArcSource Submersible II connected to the LED output 2.
"LEd3."
- temperature in the ArcSource Submersible II connected to the LED output 3.
"LEd4."
- temperature in the ArcSource Submersible II connected to the LED output 4.
In order to reset some counter to 0 you have to press and hold the UP and DOWN buttons
and at the same time press the ENTER button.
The notice "n A" means that no ArcSource Submersible II is connected to LED output.
The temperature can be displayed in either °C or °F - see option “tEM.U“ in the menu “PErS“.
"Ver.S." ---Software Versions
. Select this function to read the software version of the SubDrive 4 and
connected ArcSource Submersible II modules.
"VEr.d"
--- version of the SubDrive 4.
"VE.L.1"
--- version of the ArcSource Submersible II connected to the LED output 1.
"VE.L.2"
--- version of the ArcSource Submersible II connected to the LED output 2.
"VE.L.3"
--- version of the ArcSource Submersible II connected to the LED output 3.
"VE.L.4"
--- version of the ArcSource Submersible II connected to the LED output 4.
"VE.V.i"
--- version of the wireless DMX module (if is installed).
5.3 Personality ("PErS")
Use this menu to modify the SubDrive 4 operating behaviour.
"dM.Pr." --- DMX mode
. Select this menu item to set a desired DMX mode. Please refer to the DMX protocol
for detail description of each DMX mode.
"M. F.ti." --- Max. fade time
. Select this menu item to set a desired max. fade time (0.1-25.5 sec.). This adjusted
fade time influences fade of red, green, blue, white and dimmer during DMX operation:
If time between two receiving DMX values is > than fade time set in the item “M.F.ti.“, the entire adjusted fade
time will be used.
If time between two receiving DMX values is < than fade time set in the item “M.F.ti.“, the adjusted fade time
will be reduced to fill entire time between the two receiving DMX values.
e.g “M.F.ti.“ = 2sec. and fixture has received Red=0 DMX, after 5 seconds will receive red=255 DMX. It means,
that red will go to full intensity during 2 seconds.
“M.F.ti.“ = 8 sec. and fixture has received Red=0 DMX, after 5 seconds will receive red=255 DMX. It means,
that red will go to full intensity during 5 seconds. (Max, fade time is reduced from 8 sec. to 5 sec.).
Value "OFF" means, that this function is disabled.
"CAL.t" --- Calibrated colour temperature
. The menu item influences behaviour of the colour channels if
the channels are fully saturated (at RGBW or RGBA version). If the item is set to "Yes", the light output will be
calibrated white 5600K, if the item is set to "no", the light output will be uncalibrated white. The menu item does
not influence DMX mode 4, 7 at RGBW or RGBA version.
"rGb.C." --- White counting
. If this function is On, the white channel uses red, green and blue channels in a
proportion to the intensity of the white channel in order to maximize white output of the LED module.
If you wish to light only with white LEDs at white channel, switch this function to OFF.