Cable gland M20:
We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable
gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the
thread of the gland body in case that you need to unscrew and remove the cable gland from the housing of
the junction box and and screw it back to the housing.
Remove end caps from cable glands before passing cables into the junction box.
Fully tighten cable gland nuts and check that cables are properly fastened in the cable glands.
Note: every cable gland has to be covered with the end cap if this cable gland is not used for cable passing.
3.
After checking all connections, fill the junction box with synthetic resin. Make sure that the End cap is
inserted in unused cable gland and the earth wire for cover is pulled out of the junction box before filling it.
At filling of the junction box proceed according instructions stated on the bag of the resin.
The connection box (20) has to be fully poured in the resin.
Prepared junction box and resin bag.