Robe Anolis Eminere Inground 2 Wireless DMX Скачать руководство пользователя страница 1

     

 

  
 

Version 1.3 

Содержание Anolis Eminere Inground 2 Wireless DMX

Страница 1: ...Version 1 3 ...

Страница 2: ... 2 Table of contents 1 Safety instructions 3 2 Fixture exterior view 4 3 Installation 4 3 1 Mounting the Eminere Inground 5 4 Technical specifications 13 5 Cleaning and maintenance 15 5 1 Disposing of the product 16 6 ChangeLog 16 ...

Страница 3: ...xture falls under protection class I Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection Do not connect this fixture to a dimmer pack LED light emission Risk of eye injury Do not look into the beam from a short distance without suitable protective eyewear Do not look at LEDs with magnifiers or similar optical instruments that may concentrate th...

Страница 4: ...horized modifications on the fixture are forbidden due to safety reasons Operate the fixture only after having familiarized yourself with its functions Do not permit operation by persons not qualified to operate the fixture If this device will be operated in any way different to the one described in this manual the product may suffer damages and the warranty becomes void Furthermore any other oper...

Страница 5: ...unting sleeve 1 by unscrewing the six cap head allen bolts 5 3 In sleeve that Emineres inground wil be installed side by side the four holes 10 on the side of the mounting sleeve serve for attaching next mounting sleeve by means of the four screws M5x10 2 with washer and nuts Two rubber grommets 3 insert to the holes 9 on the side of the mounting sleeve which you will use for passing cables to nex...

Страница 6: ...box 8 screw the Eminere Inground 13 to the mounting sleeve 1 by means of the four countersunk allen head bolts M5x18 14 The crews 14 must be tightened smoothly with torque of 4Nm Do not use impact wrench 7 Screw the cover plates 15 22 on the mounting sleeve 1 by means of the six countersunk allen head bolts M5x25 16 The crews 16 must be tightened smoothly with torque of 4Nm Do not use impact wrenc...

Страница 7: ...er voltage 1 Unscrew the four screws M4x20 17 on the cover of the junction box and remove this cover 18 with gasket 19 to get access to the connection block 20 2 Connect cables to the connection block 20 Wiring of the Eminere cable CE version Core Power Connection Brown L Blue N Yellow Green earth Wiring of the Eminere cable US version Core Power Connection Black L White N Green earth The three ca...

Страница 8: ...before passing cables into the junction box Fully tighten cable gland nuts and check that cables are properly fastened in the cable glands Note every cable gland has to be covered with the end cap if this cable gland is not used for cable passing 3 After checking all connections fill the junction box with synthetic resin Make sure that the End cap is inserted in unused cable gland and the earth wi...

Страница 9: ...check they are fully tighten 8 If you install two or more Emineres Inground side by side you have to screw three types of the cover plates end 15 middle 23 and continuous 22 Insert the cover plate middle 23 between two mounting sleeves and screw rest of cover plates to the Emineres Inground by means of the countersunk allen head bolts M5x25 16 Earth wire ...

Страница 10: ...late continuous optional 23 Cover plate middle one piece is a standard part of fixture 9 Tilt adjustment The Eminere Inground can be tilted by 15 after installing it in the mounting sleeve Push and hold the small tube 24 to release the lock of the Eminere Inground and tilt the device to desired position Release the small tube 24 to lock the new position of the Eminere Inground ...

Страница 11: ...DMX before installation Examples of connection The Eminere Inground can be only linked to a transmitter by running the link procedure at DMX transmitter The Eminere Inround can be unlinked from the transmitter by running the unlink procedure at DMX transmitter or by switching off on the Eminere Inground three times while the transmitter is switched off During off on unlink procedure the Eminere In...

Страница 12: ...mber of Emineres connected in series without Booster boxes Eminere Inground 2 Wireles DMX Voltage Cable length 120V 190V 230V 277V 10 m 32 32 32 32 20 m 32 32 32 32 30 m 28 32 32 32 50 m 17 32 32 32 70 m 12 31 32 32 100 m 9 21 32 32 Eminere Inground 4 Wireles DMX Voltage Cable length 120V 190V 230V 277V 10 m 21 32 32 32 20 m 21 32 32 32 30 m 15 32 32 32 50 m 9 22 32 32 70 m 6 16 23 32 100 m 4 11 1...

Страница 13: ...0 30 x 10 10 x 60 60 x 10 35 x 70 70 x 35 15 x 90 90 x 15 Anti Skid symmetrical 18 22 35 50 65 100 Anti Skid Bi symmetrical 20 x 35 20 x 65 20 x 90 40 x 70 Wallwasher Wide Wallwasher Projected lumen maintenance 60 000 hrs L70 25 C 77 F Interface Protocol USITT DMX512 RDM Mounting method Inground mount Adjustability 15 after instalation Housing High pressure extruded aluminium body End caps Die Cas...

Страница 14: ...perature 80 C Ambient 40 C 176 F Ambient 104 F Connection Junction box Weight Eminere Inground 2 23 6 kg 52 lbs 12 2 kg 26 9 lbs Eminere Inground 2 Fixture 11 4 kg 25 lbs install Sleeve Eminere Inground 4 43 85 kg 96 67 lbs 22 65 kg 49 93 lbs Eminere Inground 4 Fixture 21 2 kg 46 74 lbs Install Sleeve Dimensions All dimensions in mm inch Eminere Inground 2 Eminere Inground 4 ...

Страница 15: ...ting Sleeve P N 10980526 Eminere Inground 4 cover plate continuous P N 10980509 Eminere Inground cover plate end P N 13053138 Cable CE WCA P N 13053139 Cable US WCA 5 Cleaning and maintenance DANGER Disconnect from the mains before starting any maintenance or cleaning work Rinse off loose dirt with low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washin...

Страница 16: ...s in the user manual Version of the manual Date of issue Description of changes 1 1 08 09 2021 Option Wireless DMX to wired DMX removed 1 2 19 10 2021 Technical specifications changed 1 3 26 11 2021 Optional accessories changed Specifications are subject to change without notice November 26 2021 Copyright 2019 2021 Robe Lighting All rights reserved Made in CZECH REPUBLIC by ROBE LIGHTING s r o Pal...