Страница 1: ...Version 1 0 QR code for user manual ...

Страница 2: ...tion 5 3 1 Mounting the fixture 5 3 2 Connection to mains 5 4 Control and connection options 7 4 1 DMX or DALI 7 4 2 Power On Off 7 4 3 DMX or Ethernet via E box 8 5 Software update 11 6 Technical specifications 13 7 Cleaning and maintenance 18 7 1 Disposing of the product 18 8 ChangeLog 18 ...

Страница 3: ...ure the power data cable is not damaged by sharp edges Do not install the unit near an open flame Refer servicing to qualified service personnel This fixture falls under protection class I Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection Do not connect this fixture to a dimmer pack LED light emission Risk of eye injury Do not look into the b...

Страница 4: ...ck levels of possible interferences above the tested levels E1 E2 E3 given by this standard e g transmitters in surrounding area before installing the equipment Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment Emission Requirements according to class B Please consider that unauthorized modifications on the fixture are forbidden due ...

Страница 5: ...tion to mains The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations This device falls under class one and must be grounded The Calumma is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 120 277 Volts 3 2 1 Junction box installation The junction box bo...

Страница 6: ... have to remove the original seal from the cable gland M20x1 5 and use the enclosed reducing seal instead of it The reducing seal for diameter of cable 4 8mm P N 13051388 is enclosed in the Junction box Remove the end cap from the cable gland before passing the cable We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into ...

Страница 7: ...l N White Data Yellow Green GND Shielding Data ground 0V Up to 32 Calummas can be connected in DMX chain DALI connection IF the 5 cored cable SJTW 5x 14AWG P N 1305 3336 is used for Calumma connection and connection among junction boxes Core Connection Core Connection Black Live L Red Data White Neutral N Orange Data Yellow Green GND Up to 64 Calummas can be connected in DALI network 4 2 Power On ...

Страница 8: ... box menu or by RDM The Standard mode is set as default Pass Thr Pass through LED modules are switched to an internal parallel connection DMX addressing of connected LED modules has to be done manually by means of the Robe Universal Interface or its wireless version Robe Universal Interface WTX and the software RDM Manager Example with junction boxes Pass Through mode is intended for this connecti...

Страница 9: ...ive L Red Data White Neutral N Orange Data Yellow Green GND Blue Data ground 0V Number of connected Calummas to one E box output depends on a cable length power voltage type of Calumma and E box operation mode The tables below state max theoretical number of Calummas connected to the one LED output of the E box Table for Pass Through mode of E boxes Calumma S MC Voltage Cable length 120V 190V 230V...

Страница 10: ... 26 32 32 32 70 m 18 32 32 32 100 m 13 32 32 32 200 m 6 16 24 32 500 m 3 6 9 14 Cable length is a total cable length between power supply e g E box and last connected Calumma Example Total cable length L1 L2 L3 L4 L5 L6 ...

Страница 11: ...d DMX or Ethernet connection via E box If the option Standard is selected from the menu E box mode the E box will be updated including connected Calumma modules You have to use the file EminereEbox lib in the ROBE Uploader for this operating mode The Standard mode is usually used in IN OUT connection without junction boxes If the option Pass Thr is selected from the menu E box mode the E box will ...

Страница 12: ...ction boxes and you need to update connected E box switch the E box to the Standard mode and use the EminereEbox lib in the ROBE Uploader to update E box After updating the E box switch it back to the Pass Trough mode DMX connection For updating of Calumma modules use the file Calumma lib Calumma lib Calumma lib ...

Страница 13: ... 30 x60 60 x30 30 x90 90 x30 Beam Angle Calumma S SC Symetrical 10 15 25 30 45 65 100 Bi symetrical 10 x 30 30 x 10 10 x 60 60 x 10 15 x 45 45 x 15 15 x90 90 x15 30 x60 60 x30 30 x90 90 x30 Asymmetrical side Asymmetrical forward Projected Lumen Maintenance L90B10 90 000 hrs Ta 25 C 77 F Compatible drivers E box Daisy 1 Output 1 Main power Input Control DMX Art Net sACN W DMX control RDM Pixel cont...

Страница 14: ...rature range 20 C 40 C 4 F 104 F Connection CE DMX connection Calumma IN Flamar 3x AWG 16 1 x 2x AWG 24 Standard 1m with bare end P N 1305 1508 Interconnecting cables Flamar 3x AWG 16 1 x 2x AWG 24 P N 1305 1508 Junction box P N 1098 0714 DALI connection Calumma IN SJTW 5x 14AWG standard 1m with bare end P N 1305 3336 Interconnecting cables SJTW 5x 14AWG P N 1305 3336 Junction box P N 1098 0714 DM...

Страница 15: ...cting cables SJTW 5x 14AWG P N 1305 3336 Junction box P N 1098 0714 DMX or Ethernet via E box and Junction box Calumma IN SJTW 6x 14AWG standard 1m with bare end P N 1305 3480 Interconnecting cables SJTW 6x 14AWG P N 1305 3480 Junction box P N 1098 0714 Weight Calumma S SC 3 44 kg 7 6 lbs Calumma S MC 3 68 kg 8 11 lbs ...

Страница 16: ...Calumma S 16 Dimensions All dimensions in mm inch ...

Страница 17: ...Calumma S 17 Junction box ...

Страница 18: ...e water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use ROBE OEM parts 7 1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life according to the local regula...