![ROBBE Corsair ARF FW004006 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/robbe/corsair-arf-fw004006/corsair-arf-fw004006_building-and-operating-instructions_1468731018.webp)
18
4. Concluding programming mode
(2 options):
1) When you hear the special tone “1515 ” move
the throttle channel to Idle within 2 seconds.
2) When you hear the sequence "beep----beep----"
move the throttle stick back to Idle within 3 se-
conds.
Tones
“beep-” /1 short tone
“beep-beep-” /2 short tones
“beep-beep-beep” /3 short tones
Values
Brake
Off
On
Battery type
Li-Ion / Li-Po
Cut-off mode
Reduced power
Full cut-off
Cut-off voltage:
Low
Medium
High.
Start up mode
Normal
Soft
Very soft
Timing:
Low
Medium
High
Warning sounds, fault-finding:
Problem
Possible reason
Solution
The motor does not start after switching on; no sound
Incorrect connection between battery and speed controller Check power circuit connection; replace plug / socket
The motor does not start after switching on;
Input voltage too high or too low
Check battery voltage
Audible warning sequence sounds: “Beep-Beep-, Beep-Beep-, Beep-Beep-”
(interval between the “Beep-Beep” sounds is about one second)
The motor does not start after switching on;
throttle signal not correct
check receiver and transmitter
Audible warning sequence sounds: “Beep-, Beep-, Beep-”
Check throttle channel lead
(interval between the “Beep-Beep” sounds is about two seconds)
The motor does not start after switching on;
Throttle stick not at bottom end-point
Move throttle stick fully back
Audible warning sequence sounds: “Beep-, Beep-, Beep-”
(interval between the “Beep-Beep” sounds is about one quarter of a second)
The motor does not start after switching on;
Throttle channel reversed
Reverse throttle channel
Special beep sequence “* 56712” sounds after two beeps (Beep-, Beep-)
Motor rotating in the wrong direction -
Connection between controller and motor not correct
Swap over any two leads between controller and motor
The motor stops when operating
Loss of throttle signal
Check receiver and transmitter
Controller in low-voltage protection mode
Land model aircraft as soon as possible, recharge battery
Certain connections not secure
Check all connections:
battery connectors, throttle channel lead, motor wires
Building and Operating Instructions - Corsair ARF
No. FW004006