SERVICING FIXTURES AND TOOLS
JG154 Cable
JG162A Cable (8 Pins)
JG162F Cable (11 Pins)
JG162Y Cable (5 Pins)
Part No.
Remarks
Used to connect the Syscon
PCB and Main PCB
Used to connect the Syscon
PCB and CRT PCB
Used to connect the test point
of SERVICE and GROUND
APJG154000
APJG162Y00
PREPARATION FOR SERVICING
How to use the Servicing Fixture
1.
2.
3.
4.
5.
6.
Unplug the connector CP351, CP4503 and CP4504, then remove the TV/VCR Block from the set.
Unplug the connector CP502, CP820 and CP850, then remove the Main PCB from the VCR Block.
Connect as shown in the below figure using the Service Fixture.
• Connect the Syscon PCB to the Main PCB with the cable JG162A and JG162F.
• Connect the Syscon PCB to the CRT PCB with the cable JG162Y.
Remove the Operation PCB from the set, then connect it with the Syscon PCB.
If necessary, connect CP351.
Short circuit between TP1001and GND with the cable JG154.
(The EOT, BOT and Reel Sensor do not work at this moment.)
At that time, the STOP/EJECT button is available to insert and eject the Cassette Tape.
Syscon PCB
JG154
TP1001
Front Cabinet
CRT PCB
CP850
CP502
Main PCB
JG162Y
JG162F
JG162A
CP820
CD810
CD850
To Ground
CP820
21Pin PCB
CP4501
CD4501
CP4504
CD4502
CP4502
APJG162A00/
APJG162F00