Roadragon LTS-3YT Скачать руководство пользователя страница 7

4.1.4 Battery Level Detect

The terminal will upload the battery level status together with the location data pack, and display the
battery level on the backend so the user could well know the balance battery , and meanwhile display
the current transmission time and the balance battery level of the next uploading pack, so the user
could have clear view on the terminal status

4.1.5 Intelligent Tracking

In case of found the door of the container is stolen or in other emergency cases and the real time
location of the container needs to be tracker, a SMS can be sent or send a command from the backend,
when the terminal starts work next time, it will receive this command and enter into track mode, and
upload the location data according to the preconfigured interval by customer until a stop tracking
command is received

4.1.6 Clock mode

The terminal could verify the timely wake up time points, maximum 4 points can be set for position
that is more accurate and connection to the server, this function could use SMS command or backend
command to set

4.1.7 Backend Specific Commands

Since the working time of the terminal is short, it is rare to receive the SMS, to ensure the command
sending efficiently, the backend uses a specific commands for MT06CW which can preset the
command, when the terminal is online, the backend will automatic send this command, to make sure
the commands is properly received.

4.1.8 Blind zone compensation

When the terminal enter into blind zone when in sleep mode, it will store the trace data according to
the preconfigured time interval and it will upload the data in the blind zone to the backend,

Содержание LTS-3YT

Страница 1: ...LTS 3YT User manual User Manuel LTS 3YT...

Страница 2: ...7 Backend Specific Commands 7 4 1 8 Blind zone compensation 7 4 1 9 E Sim 8 4 2 Extention Optional Functions 8 4 2 1 Light Sensor 8 4 2 2 Motion Detect 8 4 2 3 Temperature and humidity detect 8 Chapte...

Страница 3: ...LTS 3YT User manual 1 Chapter One Product Photo...

Страница 4: ...t different needs of customers 3 Low Voltage The working voltage can be decreased to 10 A during sleep mode to make sure the unit would work longer 4 The device supports 4G 3G 2g networks in most part...

Страница 5: ...4G network TDD LTE FDD LTE 3G network WCDMA 2G network GSM GPRS GNSS Support GPS BD Dual mode GPS L1 1575 42MHz C A Code BD B1 1561 098MHz Dimension 205mm 68mm 27mm L W H Weight 200g 5g Waterproof IP6...

Страница 6: ...on includes Position status longitude and latitude GSM Signal Strength GPS numbers battery voltage etc the upload interval can be configured the unit is able to work no less than 365 days 4 1 2 AGPS T...

Страница 7: ...location data according to the preconfigured interval by customer until a stop tracking command is received 4 1 6 Clock mode The terminal could verify the timely wake up time points maximum 4 points c...

Страница 8: ...e terminal to send alarm this function is for detecting the door open alarm purpose 4 2 2 Motion Detect Built in high sensitive low consumption G sensor to detect whether the equipment is in motion or...

Страница 9: ...tion Guide 5 1 Installation diagram Battery Switch SIM card slot Red LED Fast blink GPRS connecting Slow Blink GPRS Connected Solid on Module error Light sensor E SIM Green LED Solid on Position Blink...

Страница 10: ...rts to flash indicating that the terminal is powered on 5 2 3 Parameter setting TCP UDP connection mode setting For example the client s server IP is 119 145 40 64 port number 8881 If it is connected...

Страница 11: ...on function A 1 LBS WIFI mode A 0 GPS position priority default A 3 Examples LBS 1 enter LBS WIFI position mode Switch off GPS 5 3 4 Clock mode Command Format WAKEUP T1 T2 T3 T4 Description Set a mult...

Страница 12: ...e tracking T1 The return interval for entering the tracking mode during exercise the value range is 1 5 minutes T2 Return interval at rest value range 5 43200 minutes or alarm clock format HH MM A 1 Q...

Страница 13: ...er alarm no track A 2 Open tamper alarm track 15 minutes every 300 seconds A 1 Close tamper alarm A 0 Open tamper alarm track 60 minutes every 60 seconds Default A 0 For example FALL 0 Open tamper ala...

Страница 14: ...dby server IP as 119 23 233 52 Port as 6000 communication mode as TCP IP2 www 365qczx com 6000 0 Set standby server domain name as www 365qczx com port as 6000 communication mode UDP IP2 0 0 delete st...