T

echnical Parameters

Standard: Compliant with USBV.1, 1.0, 2.0 standard and ELA RS-485, RS-422S standard

USB signal: VCC, DATA+, DATA-, GND, FG

RS-232 signals: RXD, TXD, DTR, DSR, RTS, CTS

RS-485 signals: T/R+, T/R-, GND

RS-422 signal: T/R+, T/R-, RXD+, RXD-, GND

Working mode: 232 full duplex, asynchronous work, point-to-point or multi-point, 2-port half duplex, 4-port

 

full duplex

Direction control: Data flow direction automatic control technology, automatic control of data transmission

 

direction

Baud rate: 300-921.6Kbps, automatic detection of serial signal rate

Load capacity: support point to multi-point,  each converter can allow the connection of 256 RS-422 or

 

RS-485 interface devices

Transmission distance: RS-232 end no more than 5 meters, USB end no more than 5 meters; RS-485/422 
end no more than 1200meters (9600bps when), USB end no more than 5 meters

Interface protection: Surge protection, 

±

15KV electrostatic protection

Interface form: USB end of the Class A interface male, DB9 male connector connection

Signal approval: 2 signal approval lights send (TXD) or (RXD) 1 power indicator (POWER)

Transmission medium: twisted pair or shielded wire

Dimensions: 1000mm*36mm*16mm (L*W*H)

Operating temperature: -40 ~ 85°C

Relative humidity: 5 ~ 95%

Transmission distance: 0-1200m (485/422)

Support WinXP/7/8/8.1/10 etc.

5. Pin Definition Description

RS-232 signal pin assignment

DB9 Male (PIN) 

Output Signal 

RS-232 full duplex wiring 

N/A 

N/A 

RXD 

RXD 

TXD 

TXD 

DTR 

DTR 

GND 

GND 

DSR 

DSR 

RTS 

RTS 

CTS 

CTS 

N/A 

N/A 

   

DB9 Male 

Содержание 405-00002

Страница 1: ...USB to RS 232 485 422 Interface Converter User manual RND 405 00002 www rnd electronics com CAUTION Read the instructions before using the device...

Страница 2: ...g 4 communication methods Point to point four wire full duplex Point to multi point four wire full duplex Point to point two wire half duplex Point to multi point two wire half duplex When the convert...

Страница 3: ...RS 485 interface devices Transmission distance RS 232 end no more than 5 meters USB end no more than 5 meters RS 485 422 end no more than 1200meters 9600bps when USB end no more than 5 meters Interfa...

Страница 4: ...ication connection diagram When the mode is RS 232 DB9 Male PIN Output Signal RS 422 full duplex wiring RS 485 half duplex wiring 1 T R Transmitting A RS 485 A 2 T R Transmitting B RS 485 B 3 RXD Rece...

Страница 5: ...5 EN EN When the mode is RS 485 422...

Страница 6: ...ing F Check whether the transmitting indicator flashes when sending 2 Data loss or error A Check whether the data rate and format are consistent at both ends of the data communication equipment 8 Step...

Страница 7: ...elect Update Driver Software In the pop up window select Browse Computer to find the driver software According to their own computer system select the appropriate driver software path the following ch...

Страница 8: ...th a successful installation click close to use Windows10 system access may show a driver you need to update to a dedicated driver update the same way as the above installation 9 2 One click installat...

Страница 9: ...d keep clicking Next to complete Mode change and configuration default is RS 232 mode As shown in the figure right click on the serial device and select Properties click Port Setting to change the mod...

Страница 10: ...10 EN EN 2 RS 485 mode 3 RS 422 mode...

Страница 11: ...11 EN EN 4 Serial port number configuration...

Страница 12: ...www rnd electronics com...

Отзывы:

Похожие инструкции для 405-00002