Bedienungsanleitung TCO
4
4. Technical Specifications
4.1 TCO-FF
LTC/Video In
•
LTC In: BNC, unbalanced
•
Level range LTC In: -25 dBu up to +12 dBu
•
Video In: BNC unbalanced, switchable termination 75 Ohm
•
Format: PAL and NTSC
LTC Out
•
BNC
•
Output level: +4 dBu, via jumper –7 dBu
•
Output impedance: 220 Ohm
•
Power supply via ribbon cable, 5 V DC, 100 mA
•
Dimensions (WxD): 100 x 75 mm
4.2 TCO-HDSP
LTC In
•
BNC, unbalanced
•
Level range: -25 dBu up to +12 dBu
Video In (Word Clock In)
•
BNC, switchable termination 75 Ohm
•
Format: PAL and NTSC
Word Clock In (Video In)
•
BNC, switchable termination 75 Ohm
•
Transformer coupled, galvanically isolated input
•
Not affected by DC-offsets within the network
•
Signal Adaptation Circuit: signal refresh through auto-center and hysteresis
•
Overvoltage protection
•
Level range: 1.0 Vpp – 5.6 Vpp
•
Lock Range: 28 kHz – 200 kHz
•
Jitter when synced to input signal: < 1 ns
•
Jitter suppression: > 30 dB (2.4 kHz)
LTC Out
•
BNC
•
Output level: +4 dBu, via jumper –7 dBu
•
Output impedance: 220 Ohm
Word Clock Out
•
BNC
•
Max. output voltage: 5 Vpp
•
Output voltage @ 75 Ohm termination: 4.0 Vpp
•
Output impedance: 10 Ohm
•
Frequency range: 28 kHz – 52 kHz
•
Power supply via ribbon cable, 5 V DC, 100 mA
•
Standard bracket, dimensions PCB (WxD): 98 x 75 mm
Содержание TCO FF
Страница 12: ...Bedienungsanleitung TCO 12...