RME Audio DIGI 96/8 PRO Скачать руководство пользователя страница 19

 
 

 

User's Guide 

DIGI96/8 PRO  © RME

 

19

 

 

12. Notes on the ADAT Interface 

 

DIGI96/8 PRO

 comes with two different driver methods in one driver. Using channel 

interleave there is only one device, the software in use divides the channels into 8 mono tracks. 
Because this easy to handle 'Windows native' method is not widely used the 

DIGI96/8 

PRO

 also supports Multi-Device operation. The driver routes the 8 tracks in 4 stereo devices. 

These 4 stereo devices can be used by nearly any software to record or playback more than 2 
channels simultaneously, making 

DIGI96/8 PRO

 compatible to a wide range of already 

existing software. 

 

DIGI96/8 PRO

 includes an intelligent hardware controller for ease of use. Whenever 

more than 2 channels are used, no matter with record, playback or both, the card switches into 
ADAT mode. Whenever an ADAT signal is present at the optical input the settings dialog of the 

DIGI96/8 PRO

 indicates ‘ADAT 44,1 kHz' or 'ADAT 48 kHz'. If now the output function is 

set to ‘Input’ while AutoSync is active the card's output changes to ADAT mode to allow input 
monitoring of up to 8 channels. The analog output allows you to listen to any of the four stereo 
pairs. The desired pair can be selected in the 'Track' field of the Settings dialogue. 
 
If the software being used requires a continuous ADAT mode activate the switch ‘Force Adat' in 
the Settings dialog. 
 
When using a 'normal' 2 track program to play or record a stereo file, you're not only able to 
send the data to any SPDIF device but also to any other ADAT interface! Just activate 'Force 
Adat' and choose the stereo pair that corresponds to the desired channels (for example 
DIGI96/8 PRO (3+4)). 
 
In SPDIF mode it doesn't matter which stereo device is being used. 
 
 

13. Multiclient Operation

 

 

13.1 General 

 
The DIGI96/8 series supports multiclient operation. That means more than one program can be 
used at the same time. But this mode is only available as long as certain rules are followed. For 
a flawless multiclient operation with multiple programs the below guidelines have to be followed 
precisely. 
 

 

Rule 1: Multiclient operation always requires the activation of Force Adat! 

 

After an activation of Force Adat all 4 output pairs can be used freely. You can use 4 different 
MME programs, or two stereo pairs under ASIO, one under GSIF and one under MME – any 
combination is allowed. 
 

 

Rule 2: Multiclient operation always requires identical sample rates and bit resolutions! 

 

It is not possible to run one program at 44.1 kHz and another one at 48 kHz. Also it's not pos-
sible to run one program in 16 bit and another one in 24 (32) bit resolution. Please note that the 
selected latency (Mode) also sets the bit resolution for GSIF and ASIO! 

 

 

Содержание DIGI 96/8 PRO

Страница 1: ...de DIGI 96 8 PRO PCI Bus Audio Card 2 8 Channels Stereo ADAT Interface 24 Bit 96 kHz Digital Audio 32 96 kHz Sample Rate 24 Bit 96 kHz Analog Audio Board Rev 1 2 Hardware version 000 24 Bit 96 kHz ZLM...

Страница 2: ...ME 9 8 5 Record while Play 10 8 6 DVD Playback AC 3 DTS under MME 10 8 7 Low Latency under MME 11 9 Configuring the DIGI 96 8 PRO 9 1 General 12 9 2 Force Adat 14 9 3 Analog Output 14 9 4 Tab Mode 15...

Страница 3: ...ox PCI card DIGI96 8 PRO Quick Info guide RME Driver CD Adapter cable D type XLR Phono Internal cable 2 core 3 System Requirements Windows 95 98 NT 2000 XP Linux or MacOS A free PCI bus slot Additiona...

Страница 4: ...BA THD N output 100 dB 0 001 Frequency response DA 0 1 dB 20 Hz 20 8 kHz sf 44 1 kHz Frequency response DA 0 5 dB 10 Hz 44 kHz sf 96 kHz Sample rates playback 32 44 1 48 64 88 2 96 kHz and variable wo...

Страница 5: ...ows will install the DIGI driver and will register the card in the system as a new audio device The computer should now be re booted Unfortunately in seldom cases the path to the CD ROM i e its drive...

Страница 6: ...driver not certified driver or similar come up Don t listen to Microsoft listen to us and continue with the installati on 7 4 Deinstalling the Drivers A deinstallation of the DIGI96 series driver fil...

Страница 7: ...faders allow to change the output level from 0 dB down to 78 dB A spe cial mute circuit reduces noise when switching the computer on and off 8 2 Internal Connectors The DIGI96 8 PRO has one internal d...

Страница 8: ...s If you feel you cannot do without system sounds you should consider buying a cheap Blaster clone and select this as Preferred Device in Control Panel Multimedia Audio The RME Driver CD includes step...

Страница 9: ...an then be changed in the application s audio attributes or similar dialog The screenshot to the right shows a typical dia log used for changing basic parameters such as sample frequency and resolutio...

Страница 10: ...DVD software s audio properties now allow to use SPDIF Out or to activate SPDIF output When selecting these the software will transfer the non decoded digi tal multichannel data stream using the RME c...

Страница 11: ...buffer size is set with the same buttons as the ASIO buffer size Please note that this setting only defines the buffer size of the hardware The true and effective latency is configured within the MME...

Страница 12: ...t control the monitoring behaviour of the card Automatic sets the normal mode where the input signal reaches the output only whilst recording In this mode when starting a recording feedback occurs ver...

Страница 13: ...ter selecting Input the input sig nal appears at the output whenever playback is not active Output Format Automatic sets the output to 2 channel SPDIF or 8 channel ADAT mode according to the current u...

Страница 14: ...ardware without any additional software Activated Force Adat allows you to use the card as a format converter from SPDIF to ADAT The stereo signal at the input is copied to all 4 stereo pairs of the o...

Страница 15: ...hrough the computer record plus playback monitoring gives double values The setting of the buffer size affects all formats MME Defines lowest possible latency The current latency and bit resolution is...

Страница 16: ...ier so synchronization breaks down To remedy this switch the card s clock mode over to Master Due to the outstanding clock control and PLL a synchronization of the output signal to the input signal is...

Страница 17: ...its internal input and AutoSync mode Next connect the third card in the same way from the second s card Sync Out to the third s card Sync In Configure this card like the second one The necessary 2 wir...

Страница 18: ...ew output header is optimized for largest compatibility with other digital devices 32 kHz 44 1 kHz 48 kHz 64 kHz 88 2 kHz 96 kHz depending on the current sample rate Audio use Non Audio No copyright c...

Страница 19: ...ogue If the software being used requires a continuous ADAT mode activate the switch Force Adat in the Settings dialog When using a normal 2 track program to play or record a stereo file you re not onl...

Страница 20: ...DirectSound support un check Disable DS in the Settings dialog Additionally the driver offers multi device DirectSound This mode is not officially supported by Windows 95 98 but works perfectly for e...

Страница 21: ...st one other the card swit ches into ADAT mode Simply activate Force Adat in the settings dialog in case the ADAT format is desired when playing back only 2 tracks Record The card automatically recogn...

Страница 22: ...s double values More information on how to set up the latency under ASIO can be found in chapter 9 4 Tab Mode 14 3 Known problems In case the used computer has no sufficient CPU power and or sufficien...

Страница 23: ...ration of GSIF and ASIO requires to use different channels As Cubase VST always uses tracks 1 2 these tracks must not be activated in Gigastudio Sampler The tracks activated under GSIF have to be de a...

Страница 24: ...e for example deactivate Cubase s ASIO Direct Monitoring The SPDIF output does not work The output operates in ADAT Mode see Output Status Display This may be caused by Force Adat being activated an a...

Страница 25: ...og New hardware component found does not appear Is the Error LED of the DIGI96 8 PRO lit when no cable is connected to the optical input If not the card is either defect or not sitting properly in the...

Страница 26: ...xamples Peak level measurement RMS level measurement Over detection phase correlation measure ment dynamic range and signal to noise ratios RMS to peak difference loudness long term peak measurement i...

Страница 27: ...D 85778 Haimhausen Tel 49 08133 91810 Manufacturer IMM Elektronik Leipziger Str 27 D 09648 Mittweida Trademarks All trademarks and registered trademarks belong to their respective owners RME DIGI96 Sy...

Страница 28: ...nal cabling for example when the XLR input and output jacks shall be build into the PC housing so that the supplied cable adapter is no longer nee ded When using a 10 wire computer flat cable with the...

Страница 29: ...User s Guide DIGI96 8 PRO RME 29 Block diagram...

Страница 30: ...is subject to the following two condi tions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operat...

Отзывы: