38
User's Guide ADI-6432R BNC © RME
17. MIDI Implementation Chart ADI-6432
17.1 Basic SysEx Format
Value Name
F0h SysEx
header
00h 20h 0Dh
MIDITEMP manufacturer ID
63h
Model ID (ADI-6432)
00h..7Eh, 7Fh
Device ID. 7Fh = broadcast (all IDs)
mm Message
type
nn
Parameter number (see table 1)
oo Data
byte
F7h EOX
17.2 Message Types
Value Name
10h Request
value
20h Set
value
30h Value
response
Request Value
Format: F0 00 20 0D 63 (dev ID) 10 F7
This string triggers a complete dump of all value response data bytes.
Value Response
After being triggered by receiving a request value command, device sends a string of all value
response data bytes. Message type is set to 30h.
Set Value
Sets any number of parameters.
nn / oo can be repeated freely.
17.3 MADI Input State – Redundancy Mode
The MADI input can be BNC or optical. When the ADI-6432 enters Redundancy mode, it uses
the other input, although not chosen and signalled by the MADI input select byte. See below
table.
MADI Input Select
MADI Input State
Actual input in use
0 = BNC
0 = normal operation
BNC
1 = Optical
0 = normal operation
Optical
0 = BNC
1 = Redundancy mode
Optical
1 = Optical
1 = Redundancy mode
BNC
Содержание ADI-6432(r)
Страница 5: ...User s Guide ADI 6432R BNC RME 5 User s Guide ADI 6432R BNC General...
Страница 13: ...User s Guide ADI 6432R BNC RME 13 User s Guide ADI 6432R BNC Usage and Operation...
Страница 25: ...User s Guide ADI 6432R BNC RME 25...
Страница 28: ...28 User s Guide ADI 6432R BNC RME...
Страница 29: ...User s Guide ADI 6432R BNC RME 29 User s Guide ADI 6432R BNC Technical Reference...
Страница 37: ...User s Guide ADI 6432R BNC RME 37 16 Block Diagram...