Страница 1: ...Monitoring F110 User Guide...

Страница 2: ...rieval system without the prior written permission of RLE Technologies Trademark Notices RLE is a registered trademark and Falcon Raptor and SeaHawk are trademarks of RLE Technologies All other tradem...

Страница 3: ...ential RLE will not sell or distribute any of the information to third parties To read our Privacy Policy please visit our website www rletech com Technical Support Personal assistance is available Mo...

Страница 4: ...rletech com 4 970 484 6510 Notes...

Страница 5: ...F110 Wiring 17 Power Supply 17 RJ45 Ethernet Connection 18 3 F110 Web Interface 19 F110 Web Interface Overview 19 Status Screen 19 Settings Screen 20 Network 21 Email 22 SNMP 23 Channel 2 Channel 3 a...

Страница 6: ...970 484 6510 6 rletech com Notes...

Страница 7: ...ure 2 5 F110 Ethernet Connection to a PC on a Subnet 18 3 F110 Web Interface 19 Figure 3 1 F110 Status Screen 19 Figure 3 2 Authentication Security Prompt no Username or Password 20 Figure 3 3 Network...

Страница 8: ...rletech com 8 970 484 6510 Notes...

Страница 9: ...t Registers 31 Table B 2 Family Code Register 40002 40009 40016 40023 FC 32 Table B 3 Status Flags Register 40003 SS 32 Table B 4 Status Flags Register 40004 SC 33 Table B 5 Status Flags Register 4000...

Страница 10: ...970 484 6510 10 rletech com Notes...

Страница 11: ...3 digital temperature humidity sensors or 3 digital temperature only sensors and up to 8 dry contact sensors signal quality contacts that can be distributed at locations spanning up to 100 feet 30m A...

Страница 12: ...On if power is on Network Link Green On if a network connection is found Network Activity LED Green On if network communication is occurring Front Panel Power 5VDC wall adapter input center Network R...

Страница 13: ...ignations Rear Panel Switch Sensor Port 1 Digital Input 1 Switch Sensor Port 2 Digital Input 2 Switch Sensor Port 3 Digital Input 3 Switch Sensor Port 4 Digital Input 4 Switch Sensor Port 5 Digital In...

Страница 14: ...www rletech com 14 970 484 6510 1 System Overview Notes...

Страница 15: ...locates all F110 devices connected to the network This provides an efficient way to manage large numbers of F110 devices from a single host system Note The default DHCP name on the F110 is F110 5 dig...

Страница 16: ...lly via DHCP Figure 2 2 IP Pop up Box 2 2 3 IP Address Assignment for Static Only Networks If the network is not configured for DHCP a static IP address will need to be set before the F110 can be acce...

Страница 17: ...date file has a zip extension replace zip with upd before uploading the file with the Device Discovery Utility 2 3 F110 Wiring RLE recommends an 18AWG stranded copper wire for connection from each mon...

Страница 18: ...and monitor the F110 The Ethernet port supports Web browser access email SMTP Modbus and SNMP The following figures show the physical connection Figure 2 4 Physical Connection Figure 2 5 shows a typic...

Страница 19: ...abled computer Enter the IP address of the F110 into your web browser s address bar The F110 Main Page will appear 3 2 Status Screen Figure 3 1 F110 Status Screen The Falcon F110 Status Screen is avai...

Страница 20: ...o the manual of each sensor for information on the normal state open or closed of the switch sensor in use Below the DHCP Name and time display are a number of radio buttons and form fields that allow...

Страница 21: ...ox and enter the Static IP Gateway IP and Subnet Mask If you wish to use a DNS name instead of an IP address for the Mail Server Address on the Email tab enter the IP address of your DNS Server in the...

Страница 22: ...nter a single regular email address distribution list email address or mobile phone pager or PDA email address using Email To SMS for email alert when alert thresholds are exceeded Only one address ma...

Страница 23: ...network monitoring applications Enter the Community Name to use for accessing the SNMP data via SNMP Query for the F110 sensors If the SNMP feature of the F110 is used F110 MIB files are available for...

Страница 24: ...ity sensor If the current temperature and or humidity rises above the high threshold or falls below the low threshold an alert will be generated When the temperature and or humidity returns to a norma...

Страница 25: ...F110 are set by specifying either CLOSED or OPEN Please refer to the documentation received with any sensor purchased to determine the normal state open or closed for that specific sensor type Next se...

Страница 26: ...ting to other equipment If you wish to modify the time display on the Status screen to the local time zone use the drop down box to select your local time zone check the Daylight Savings Time checkbox...

Страница 27: ...tion is not being made To use Tracing Output click on the enable tracing box save your settings Go back to the Advanced screen after the changes have been made and left click the View Tracing Output b...

Страница 28: ...here are hyperlinks available for contacting RLE Technologies RLE Technical Support and Web Site link for viewing other RLE products and information Figure 3 10 Help Screen 3 3 10 About Screen The Abo...

Страница 29: ...us can be configured through the F110 Telnet interface To open the Telnet interface type the following on the command line being sure to replace IP Address with the IP address of the F110 telnet IP Ad...

Страница 30: ...ices In other words by default the F110 allows connections from all IP addresses This can be modified if desired so that the F110 will only allow connections from IP addresses appearing in the IP list...

Страница 31: ...rent Humidity External Sensor 1 Relative Humidity 0 65535 40014 HH High Humidity External Sensor 1 Relative Humidity 0 65535 40015 HL Low Humidity External Sensor 1 Relative Humidity 0 65535 40016 FC...

Страница 32: ...Low Temperature External Sensor 2 Fahrenheit x100 0 65535 40052 TC Current Temperature External Sensor 3 Fahrenheit x100 0 65535 40053 TH High Temperature External Sensor 3 Fahrenheit x100 0 65535 40...

Страница 33: ...06 Switch Sensor 7 Alarm On 1 Closed 0 Open 07 Switch Sensor 8 Alarm On 1 Closed 0 Open 08 15 Spare Table B 5 Status Flags Register 40005 AS Bit Status Flag 00 Switch Sensor 1 Alarm State 1 Alarm 0 N...

Страница 34: ...www rletech com 34 970 484 6510 B Modbus Registers Notes...

Страница 35: ...BaseT RJ45 connector DHCP enabled default Static IP addressable Protocols TCP IP NTP IPv4 0 HTTP HTML Telnet 1 1 4 0 SNMP V1 NMS manageable with Get and Traps V2c Traps or Informs SMTP Email Slave RTU...

Страница 36: ...10 oz 283g Rack Mount Optional 20 oz 567g Mounting Rack mount brackets required F110 RMB rack mount brackets not included Temperature Sensor Optional F110 TS optional includes 25ft 7 62m leader cable...